American Power Conversion AIS 5000 manual User Safety, Disconnect all sources of AC and DC power

Page 8

User Safety

 

WARNING!

 

This UPS contains hazardous AC and DC voltages. Only qualified electricians

 

should connect the UPS, AC line and external batteries, and must be familiar with

 

batteries and battery installation.

 

Before installing, maintaining or servicing the UPS, shut off the UPS and

 

disconnect all sources of AC and DC power.

 

As the UPS has no built-in disconnection devices to switch off external AC and DC

 

input power, ensure that disconnection devices are available as separate parts in

 

connection with the installation!

 

AC and/or DC voltage will always involve a potential risk of AC voltage at UPS

 

output generated from either batteries or utility. To avoid equipment damage or

 

personal injury, always assume that there may be voltage at UPS output.

 

This system is equipped with an auto-start function. If activated, the system may

 

start without warning. Refer to the “Programming” section for information on de-

 

activation.

 

The installer must provide each external disconnecting device for this UPS system

 

with labels with the following text:

 

“Isolate the Uninterruptible Power Supply (UPS) as instructed in this guide before

 

working on circuit”

 

WARNING!

 

TEST BEFORE YOU TOUCH!

 

To reduce the risk of fire or electric shocks, install the UPS and external batteries

 

in a temperature and humidity controlled indoor area, free of conductive

 

contaminants.

 

WARNING!

 

UPS batteries are high-current sources. Shorting battery terminals, DC terminals

 

or DC busbars can cause severe arcing, equipment damage and injury. A short

 

circuit can cause a battery to explode. Always wear protective clothing and eye

 

protection and use insulated tools when working on batteries.

 

CAUTION!

 

This unit contains components sensitive to electrostatic discharge (ESD). If you do not

Caution

follow the ESD procedures, you may cause severe damage to electronic components.

 

990-2440

AIS 5000 400V Installation Manual

2

Image 8
Contents AIS Page Contents Options Operation Modes Page Safety Symbols used in this manualUser Safety Disconnect all sources of AC and DC powerGeneral Information About this manualSite Requirements Receiving and inspecting the UPSMoving the equipment to site Air Filter Fitting the air filterAir filter sizes Enclosure dimensions and footprint Enclosure dimensionsTop and bottom view of 10-30kVA UPS Top and bottom view of 40-60kVA UPS Top and bottom view of 80-100kVA UPS Connecting the UPS External connection boardInstalling Conduit Boxes  UPS Feet  Conduit Box  Front of Conduit BoxInput Conduit Output/Bypass Battery Alarm Conduit Access to Input/Output section Low-voltage section cover Communication Interface, EPO Connecting cables Input/Output -60 kVA Input/Output -100 kVA Grounding X090Emergency Power Off EPO Communication interfaceCommunication interface ports COM-PORTCOM Interface Overview of Communication interface10kVA 400V UPS Nominal Voltage 240 Max. Discharge Current a 46 aEmergency Power Off EPO Yes Approvals IEC 62040/EN 50091 Class A, VFI-SS-112Options Mains Voltage 400 V 3 Wire + G Nom 19.88 kW 33.79 a Voltage 400 V 3 Wire + N + G Nominal Current 28.9 a20kVA 400V UPS Max 39.4 aMax. Discharge Current a 91 a External Connection 20kVA 400V UPS Options Mains Voltage 400 V 3 Wire + G Nom 28.35 kW 47.86 a Voltage 400 V 3 Wire + N + G Nominal current 43.3 a30kVA 400V UPS Max 59.9 aMax. Discharge Current a 135 a External Connection 30kVA 400V UPS Options Mains Voltage 400 V 3 Wire + G Nom 36.9 kW 61.93 a Voltage 400 V 3 Wire + N + G Nominal current 57.7 a40kVA 400V UPS Max 77.8 aMax. Discharge Current a 179 External Connection 40kVA 400V UPS Options Mains Voltage 400 V 3 Wire + G Nom 54.42 kW 90.08 a Voltage 400 V 3 Wire + N + G Nominal current 86.6 a60kVA 400V UPS Max 117 aMax. Discharge Current a 266 External Connection 60kVA 400V UPS Options Mains Voltage 400 V 3 Wire + G Nom 72.33 kW 118.23 a Voltage 400 V 3 Wire + N + G Nominal current 115.5 a80kVA 400V UPS Max 152.8 aMax. Discharge Current a 353 External Connection 80kVA 400V UPS Options 100kVA 400V UPS Max. Discharge Current a 442 External Connection 100kVA 400V UPS Options Options IP32 Drip Shield Mounting the drip shield Drip shield sizes Relay Board MessageMessage Communication Cards Cards and slotsDisplay Display introductionDisplay functions Display messages Keys Until the display shows Programming the UPSUser stack Programming and Set-Up Programming the UPS Bypass Operation Push Cursor keysAuto Boost Charge OFF Battery Capacity Test ??? Battery Monitor Alarm Settings for redundant systems Enter new time HH.MM.SS 10 kVA 20 kVA 30 kVA 40 kVA 60 kVA 80 kVA 100 kVA Setting stackMinutes How to change factory settings Operation mode descriptions Operation ModesPress Normal to Bypass OperationBypass to Normal Operation Normal to Manual Bypass Operation Load is now supported by the UPS Page 990-2440