TM-U375 DIP-switch functions
DIP Switch Set 1
SW Function |
| ON | OFF | |
Data reception | error | Ignored | Prints ' ? ' | |
Receive buffer | capacity | 40 bytes | 4K bytes | |
Handshaking |
| XON/XOFF | DTR/DSR | |
Word length |
| 7 bits | 8 bits | |
Parity check |
| Yes | No | |
Parity selection |
| Even | Odd |
Transfer Speed (BPS) | SW7 | SW8 |
1200 | ON | ON |
2400 | OFF | ON |
4800 | ON | OFF |
9600 | OFF | OFF |
BPS: Bits Per Second
DSW2
SW | Function | ON | OFF |
Connection of display module | Connected | Not connected | |
| (see Note 1 on the next page) |
|
|
Selects number of characters | 42 CPL/ | 40 CPU | |
| per line (CPL) | 35 CPL | 33 CPL |
| 7 X 9 font/5 X 9 font |
|
|
| (refer to the Notes on Number of Printable | Columns section in Chapter 4) | |
Handshaking operation | Receive | ||
| (busy condition) | buffer full | receive buffer full |
For internal use only. |
|
| |
For internal use only. |
|
| |
For internal use only. |
|
| |
Pin 6 reset signal |
|
| |
| (see Note 2 on the next page) | Used | Not used |
Pin 25 reset signal |
|
| |
| (see Note 2 on the next page) | Used | Not used |
Do not change the settings of switch 2-4, 2-5 and 2-6.
Setting Up the Printer