Toshiba S20 instruction manual Precautions on using Active Star Coupler

Page 24

TOSLINE-S20 Active Star Coupler (ASC25) Instruction Manual

6F3B0360

8.Precautions on using Active Star Coupler

(1)Precautions on the function of preventive means to single-wire breaking

Observe the following-listed cautions on using the function of preventive mean to single-

wire breaking.

Even if the function is set, it is not actuated for about 10 seconds after power "ON".

In the case that the power is "ON" while the function was not set, when the function is set in that state, (or when the switch is turned to "ON" position), the function is not actuated for about 10 seconds after the switch is turned "ON", and after that, the function is actuated.

In the case that ASC25s are connected in daisy-chain, (in the case of CH1 and CH10 are used), the actuation of the function that brings the resume operation between ASC25s becomes troublesome. Accordingly, in normal operation, we recommend to not use the function. Nevertheless, for a special case (e.g., the system operation is required to continue even under wire-breaking between ASC25s), the function may be actuated based on the judgment during system design.

(2)General precautions for the Active Star Coupler

Do not remove the unit cover.

On using the optical fiber cables, care should be paid not to contaminate the edge faces of the optical connectors. Since the optical parts have finely finished structures, care should be given not to apply shock and unnecessary force to the parts. For handling and cleaning of optical parts, refer to the "Installation and wiring" of the instruction manual.

Optical connectors of ports not in operation shall be provided with respective covers.

The mark indicates "DANGER". The label is attached to the portions that may

induce injury.

The precautions on the places around the terminal block with the mark are the following.

The protective cover on the terminal block at front face of the unit has sharp corners. Special care should be paid for handling the cover.

During power acceptance to the Active Star Coupler, skin contact to the terminals on the terminal block may induce electrical shock. Therefore, the protective cover shall be firmly attached. During power acceptance to the Active Star Coupler, do not touch the terminals.

TOSLINE S20

23

Image 24
Contents TOSLINE-S20 3 B 0 3 6Table of Contents Precautions on ordering cables/cords Introduction Page Overview Page System Configurations Page Outline of Functions Page Specifications Page External dimensions HardwareProduct construction Component identification Function setting switch TX1Page Power LED displayOptical connector Terminal block Fuse holder Start up and Power down methods Power down methodStart up method Page Precautions on using Active Star Coupler Page Installation and Wiring Method for mounting the main unitRecommended mounting position Method for connecting an Active Star Coupler with stations Connection of optical fiber cables cordsOptical parts DCV-HC-20/07 Optical connector CF-2001H Cord length Precautions on handling optical fiber and optical connector Edge position of F07 Type connectorTosline S20 Method of F07optical connector assembly 10 Removal of housing13 Residual length of core cover Page Plug-holding cap Spring Procedure of design for laying optical fiber cables Transmission side end Precautions on ordering cables/cords Precautions on laying cables