Toshiba S20 instruction manual Transmission side end

Page 38

TOSLINE-S20 Active Star Coupler (ASC25) Instruction Manual

6F3B0360

Transmission side end

Receiving side end

Receivable range

Margin

Applied optical cable gives 6 dB/km of transmission loss, (under the use of H-PCF).

Connector connection loss is 1 dB/both ends, (2 dB/both ends for non-polishing

case).

At 7 dB of loss (the worst case), 1 km of transmission is possible with a margin of 4 dB.

Figure 9.16 Example of level diagram of an optical fiber cable system

(2)Selection of terminal treatment

For selecting wiring cable and cord, the following-described precautions shall be observed.

Wiring within cubicle

For the case of intra-cubicle wiring with several meters of length, cords are convenient. Since, however, cords are weak in mechanical strength, the cords shall be fixed at about

two meters of intervals to avoid free-moving of the cords and to avoid direct application of self- weight onto a connector.

Use of plurality of aligners increases the connection loss and causes troubles. The number of aligners shall be minimized. And, if the aligners are used, secure a margin on the light level diagram.

Wiring outside cubicle

For the case of outside cubicle wiring, we recommend to use cables in view of durability. The cable shall be a cord-integrated cable. On laying the cables at site, attach optical connectors to the cables referring to "9.5 Method of optical connector assembly" and the technical documents issued by the optical cable manufacturer.

TOSLINE S20

37

Image 38
Contents TOSLINE-S20 3 B 0 3 6Table of Contents Precautions on ordering cables/cords Introduction Page Overview Page System Configurations Page Outline of Functions Page Specifications Page Product construction External dimensionsHardware Component identification Function setting switch TX1Page Power LED displayOptical connector Terminal block Fuse holder Start up method Start up and Power down methodsPower down method Page Precautions on using Active Star Coupler Page Installation and Wiring Method for mounting the main unitRecommended mounting position Method for connecting an Active Star Coupler with stations Connection of optical fiber cables cordsOptical parts DCV-HC-20/07 Optical connector CF-2001H Cord length Precautions on handling optical fiber and optical connector Edge position of F07 Type connectorTosline S20 Method of F07optical connector assembly 10 Removal of housing13 Residual length of core cover Page Plug-holding cap Spring Procedure of design for laying optical fiber cables Transmission side end Precautions on ordering cables/cords Precautions on laying cables