Toshiba G8000 Series operation manual Battery

Page 21

The meaning of symbols used in the cautionary markings are as follows:

1)

The exclamation mark within a triangle is intended to tell the user or the service personnel that cautionary markings are located with “CAUTION,” “WA RNING,” or “DANGER.”

2)

The lightning flash with arrowhead within a triangle is intended to tell the user or the service personnel that parts inside the product are a risk of electric shock to personnel.

3)

The ground symbol in a blue circle is intended to tell the user or the service personnel the location of the equipment-grounding conductor.

A

DANGER

CONTAINS PARTS NOT SERVICEABLE BY THE USER

Do not remove cover

No user serviceable parts inside.

Refer servicing to qualified service personnel.

Intended for installation in a controlled environment.

C

(For 100/150/225kVA)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USE COPPER CONDUCTORS ONLY

 

 

 

 

 

 

REFER TO INSTRUCTION MANUAL REGARDING

 

 

 

 

TIGHTENING TORQUE OF TERMINAL BLOCKS.

 

 

 

 

 

 

1

 

2

3

4

5

6

 

7

8

 

9

10

11

12

13

 

 

U

V

W

U

V

W

N

U

V

W

N

-

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

480V

 

 

 

 

480V

 

 

 

 

 

480V

 

 

400V

AC INPUT

 

 

BYPASS INPUT

 

 

AC OUTPUT

BATTERY

BD

RISK OF ELECTRIC SHOCK

This UPS receives power from more than one source-disconnection of all sources is required to de-energize this unit before servicing.

Dangerous electric charge may be stored in capacitors and associated circuitry.

Wait at least five (5) minutes for power to dissipate then check voltage before servicing.

WARNING

CRITICAL FUSE SIZING

Incorrect fuse replacement size may result in fire or inadequate equipment protection.

Replace only with same type and rating of fuse.

F

E

DANGER

RISK OF ELECTRIC SHOCK

Capacitors stay charged after power has been shut off.

Accidental contact with live parts can cause personal injury and death.

Turn off and lock out all power sources.

Wait at least five (5) minutes for power to dissipate then check voltage before servicing.

DANGER

RISK OF ELECTRIC SHOCK OR ELECTRIC ENERGY-HIGH CURRENT LEVELS

Dangerous electric charge may be stored in capacitor and associated circuitry.

Test before touching.

20

Image 21
Contents Document Number February Uninterruptible Power System UPS G8000 SeriesIntroduction Uninterruptible Power Supply Contacting Toshiba’s Customer Support Center Manual’s Purpose and ScopeTable of Contents Safety Alert Symbol General Safety InstructionsSpecial Symbols Qualified Personnel only Maintenance PrecautionsPage Storing Conditions Storage PreparationDisposal Storage MaintenanceConductor Routing and Grounding Installation PrecautionsDo not install the UPS close to a water source UPS is to be installed in a controlled environmentConnect ground wire to the earth ground terminal only MandatoryOperating Precautions Important Safety Instructions Safety Precautions Do not open the front cover Personal injuryFaults by removing these panels Do not remove the rear/side panelsOperators should be certified* personnel UPS exterior showing warning label locations Labeling RequirementsUPS exterior/interior showing warning labels Battery Grounding Electrode Terminal Handling Precautions Do not operate the UPS in wet locations Keep the reset button pressed for 5 seconds to reset the UPSDo not open the front and/or rear panel Outline and LayoutShows the outline dimensions of the 300kVA UPS Recommended Cable Size and Tightening Torque for 150kVA UPS UPS ConnectionsCable knockout plates at the bottom 150 and 225kVA Recommended Cable Size and Tightening Torque for 225kVA UPSRecommended Cable Size and Tightening Torque for 300kVA UPS Battery Bypass InputCable knockout plates at the top 300kVA Recommended LugsOperating Switches Operating SwitchesControl Functions UPS Circuit ConfigurationKey-Switch and Buttons Key-switchKey-switch function Name Function Remarks Operating Buttons Button functionsName Function Remarks External Connections External ConnectionsLED Indication Graphics InterfaceName Function LCD/LED LegendScroll up Scroll down LCD IndicationAC- I O AC-VOSync VoltDischarging 15MIN DC-VBatt No Alarm No Warning No Fault No WarningFuse Blown Another ItemUPS 35H Battery 56MIN Operation Types OperationOperators should be qualified/trained personnel Operate the UPS in the specified conditionPre-operational check ProceduresLED legend Off Flash System InitializePress the RUN button For 0.5 sec Startup Procedures Cont’dPress ‘UPS’ Switch Stopping procedure StopMove #72B to ‘OFF’ Position Complete Shutdown Step Procedure LCD/LED Status Press ‘RUN’ SwitchComplete Shutdown BATT-V BattFloat Charge LED Float Charge LED is On Equal Charge LED is Off Goes away Press FLOAT/EQAUL Button for 0.5 secFloat Charge is On Equal CAHRGE* LED is Off Types of Errors TroubleshootingFault Data Screen LCD Fault DisplaysNumber of the message in the detection order 1 UPS Fault MessagesLCD Message Description Indication LCD Scroll with faults or warnings When the UPS has stopped due to a fault, be sure to removeData needed to determine the cause of the fault UPSChanging screens with scroll buttons Scroll ButtonsRestoring UPS Operation Contact Toshiba in the event of malfunction or faultDo not attempt to modify or relocate the UPS Do not open the front and/or rear panelsUPS Specifications General SpecificationMechanical Specification Rated Capacity 150kVA 120kW 225kVA 180kW 300kVA 240kW Electrical SpecificationWord Definitions Appendix