Toshiba G8000 Series operation manual Number of the message in the detection order 1

Page 54

15.2.2 Warning Data Screen

These screens appear when a warning has occurred. Up to 10 screens can be displayed. Figure 18 and Table 21 show an example of the screen and describe the data shown in the screen.

￿

FAULTS & WARNINGS

1 UPS OVER LOAD

09-09-02 08:05:30

￿ANOTHER ITEM

￿

￿

￿

 

 

Figure 18 - Warning Screen Example.

 

 

Table 21 - Warning Data Screen Descriptions.

 

 

 

No.

Name

Description

 

 

 

￿

No

The number of the message in the detection order (1 - 10).

(Up to 10 screens of warning data can be displayed.)

 

 

 

 

 

￿

Warning

Shows the nature of the warning. For details, see section "Fault

Message

Messages".

 

 

 

 

￿

Time

The date and time (in 24-hour format) the warning was detected.

 

 

Indicates whether there is a warning screen before or after this screen.

 

Scroll indicator

Indicates there is a warning screen above this screen.

￿

Indicates there is a warning screen below this screen.

 

 

−↓ Indicates there are warning screens both above and below this

 

 

screen.

 

 

 

53

Image 54
Contents Uninterruptible Power System UPS G8000 Series Document Number FebruaryIntroduction Uninterruptible Power Supply Manual’s Purpose and Scope Contacting Toshiba’s Customer Support CenterTable of Contents General Safety Instructions Safety Alert SymbolSpecial Symbols Maintenance Precautions Qualified Personnel onlyPage Storage Preparation Storing ConditionsStorage Maintenance DisposalInstallation Precautions Conductor Routing and GroundingConnect ground wire to the earth ground terminal only UPS is to be installed in a controlled environmentDo not install the UPS close to a water source MandatoryOperating Precautions Important Safety Instructions Safety Precautions Personal injury Do not open the front coverFaults by removing these panels Do not remove the rear/side panelsOperators should be certified* personnel Labeling Requirements UPS exterior showing warning label locationsUPS exterior/interior showing warning labels Battery Grounding Electrode Terminal Handling Precautions Keep the reset button pressed for 5 seconds to reset the UPS Do not operate the UPS in wet locationsOutline and Layout Do not open the front and/or rear panelShows the outline dimensions of the 300kVA UPS UPS Connections Recommended Cable Size and Tightening Torque for 150kVA UPSRecommended Cable Size and Tightening Torque for 225kVA UPS Cable knockout plates at the bottom 150 and 225kVABattery Bypass Input Recommended Cable Size and Tightening Torque for 300kVA UPSRecommended Lugs Cable knockout plates at the top 300kVAOperating Switches Operating SwitchesUPS Circuit Configuration Control FunctionsKey-Switch and Buttons Key-switchKey-switch function Name Function Remarks Operating Buttons Button functionsName Function Remarks External Connections External ConnectionsGraphics Interface LED IndicationLCD/LED Legend Name FunctionLCD Indication Scroll up Scroll downSync AC-VOAC- I O VoltDischarging 15MIN DC-VBatt Fuse Blown No Fault No WarningNo Alarm No Warning Another ItemUPS 35H Battery 56MIN Operators should be qualified/trained personnel OperationOperation Types Operate the UPS in the specified conditionLED legend Off Flash ProceduresPre-operational check System InitializeStartup Procedures Cont’d Press the RUN button For 0.5 secPress ‘UPS’ Switch Stopping procedure StopMove #72B to ‘OFF’ Position Complete Shutdown Press ‘RUN’ SwitchComplete Shutdown Step Procedure LCD/LED Status BATT-V BattFloat Charge LED Float Charge LED is On Equal Charge LED is Off Goes away Press FLOAT/EQAUL Button for 0.5 sec Float Charge is On Equal CAHRGE* LED is Off Troubleshooting Types of ErrorsLCD Fault Displays Fault Data ScreenNumber of the message in the detection order 1 Fault Messages UPSLCD Message Description Indication Data needed to determine the cause of the fault When the UPS has stopped due to a fault, be sure to removeLCD Scroll with faults or warnings UPSScroll Buttons Changing screens with scroll buttonsDo not attempt to modify or relocate the UPS Contact Toshiba in the event of malfunction or faultRestoring UPS Operation Do not open the front and/or rear panelsUPS Specifications General SpecificationMechanical Specification Electrical Specification Rated Capacity 150kVA 120kW 225kVA 180kW 300kVA 240kWAppendix Word Definitions
Related manuals
Manual 41 pages 8 Kb