Toshiba G8000 Series operation manual UPS 35H Battery 56MIN

Page 42

13.2.4 LCD Scroll

All the screens can be scrolled with the up/down buttons on the graphic panel.

Name

Description

 

 

SCROLLUP

Moves back to the previous screen

 

(see Figure 10)

SCROLL DOWN

Moves forward to the next screen

 

(see Figure 10)

Initial screen <Normal screen>

UPS SUPPLY

AC-VO

480[V]

AC- I O

50[%]

OPERATION MODE

NORMAL OPERATION MODE

SYNC.

The electric power flow is illustrated.

O/P VOLTAGE

VOLT. 480[V]

FREQ. 60.0[Hz]

Figure 14 - LCD Scroll Circulation.

FAULTS & WARNINGS

NO FAULT

NO WARNING

CLOCK

TIME 03-24-02 12:58

MODE COUNT

UPS 35[H] BATTERY 56[MIN]

32[TIM]

DC INPUT

DC-V 632[V]

BATT-V 400[V]

BATT- I 0[A]

O/P CURRENT (r.m.s)

U50[%]

V50[%]

W50[%]

O/P CURRENT (PEAK)

U50[%]

V50[%]

W50[%]

O/P CURRENT (r.m.s)

U135[A]

V135[A]

W135[A]

O/P CURRENT (PEAK)

U191[A]

V191[A]

W191[A]

BATTERY

BACK-UPRATING 10[MIN] DISCHARGING 15[MIN]

BYPASS INPUT

BYPI/P-V 480[V]

FREQ. 60.0[Hz]

AC INPUT

AC I/P-V 480[V]

FREQ. 60.0[Hz]

41

Image 42
Contents Uninterruptible Power System UPS G8000 Series Document Number FebruaryIntroduction Uninterruptible Power Supply Manual’s Purpose and Scope Contacting Toshiba’s Customer Support CenterTable of Contents General Safety Instructions Safety Alert SymbolSpecial Symbols Maintenance Precautions Qualified Personnel onlyPage Storage Preparation Storing ConditionsStorage Maintenance DisposalInstallation Precautions Conductor Routing and GroundingConnect ground wire to the earth ground terminal only UPS is to be installed in a controlled environmentDo not install the UPS close to a water source MandatoryOperating Precautions Important Safety Instructions Safety Precautions Personal injury Do not open the front coverFaults by removing these panels Do not remove the rear/side panelsOperators should be certified* personnel Labeling Requirements UPS exterior showing warning label locationsUPS exterior/interior showing warning labels Battery Grounding Electrode Terminal Handling Precautions Keep the reset button pressed for 5 seconds to reset the UPS Do not operate the UPS in wet locationsOutline and Layout Do not open the front and/or rear panelShows the outline dimensions of the 300kVA UPS UPS Connections Recommended Cable Size and Tightening Torque for 150kVA UPSRecommended Cable Size and Tightening Torque for 225kVA UPS Cable knockout plates at the bottom 150 and 225kVABattery Bypass Input Recommended Cable Size and Tightening Torque for 300kVA UPSRecommended Lugs Cable knockout plates at the top 300kVAOperating Switches Operating SwitchesUPS Circuit Configuration Control FunctionsKey-Switch and Buttons Key-switchKey-switch function Name Function Remarks Operating Buttons Button functionsName Function Remarks External Connections External ConnectionsGraphics Interface LED IndicationLCD/LED Legend Name FunctionLCD Indication Scroll up Scroll down Sync AC-VO AC- I O VoltDischarging 15MIN DC-VBatt Fuse Blown No Fault No WarningNo Alarm No Warning Another ItemUPS 35H Battery 56MIN Operators should be qualified/trained personnel OperationOperation Types Operate the UPS in the specified conditionLED legend Off Flash ProceduresPre-operational check System InitializeStartup Procedures Cont’d Press the RUN button For 0.5 secPress ‘UPS’ Switch Stopping procedure StopMove #72B to ‘OFF’ Position Complete Shutdown Press ‘RUN’ SwitchComplete Shutdown Step Procedure LCD/LED Status BATT-V BattFloat Charge LED Float Charge LED is On Equal Charge LED is Off Goes away Press FLOAT/EQAUL Button for 0.5 secFloat Charge is On Equal CAHRGE* LED is Off Troubleshooting Types of ErrorsLCD Fault Displays Fault Data ScreenNumber of the message in the detection order 1 Fault Messages UPSLCD Message Description Indication Data needed to determine the cause of the fault When the UPS has stopped due to a fault, be sure to removeLCD Scroll with faults or warnings UPSScroll Buttons Changing screens with scroll buttonsDo not attempt to modify or relocate the UPS Contact Toshiba in the event of malfunction or faultRestoring UPS Operation Do not open the front and/or rear panelsUPS Specifications General SpecificationMechanical Specification Electrical Specification Rated Capacity 150kVA 120kW 225kVA 180kW 300kVA 240kWAppendix Word Definitions
Related manuals
Manual 41 pages 8 Kb