The following chart lists the S36 and S48 configuration settings necessary to negoti- ate certain types of connections:
|
| S48=7 | S48 =128 |
| S36 = 0, 2 | LAPM or hangup | do not use |
| S36 = 1, 3 | LAPM or async | async |
| S36 = 4, 6 | LPAM, MNP, or hangup | MNP or hangup |
| S36 = 5, 7 | LAPM, MNP, or async | MNP or async |
S89 | Timer to Control Sleep Mode |
| |
| Range: | 0, |
|
| Default: | 10 |
|
This command displays the number of seconds of inactivity (no characters sent from the DTE, no RING) in the
If a number between 1 and 4 is entered for this register, it will set the value to 5, and the inactivity before standby will be 5 seconds. This is done for compatibility with previous products which allowed
S90 | Local Phone Status |
0= local phone
1= local phone
This register tells the status of the local phone. It is read only.
S91 | Line Transmit Level |
Range: | |
Default: | 15 |
Units: | 1 dB |
This register is effective only for Japan. It specifies the line transmit level in dB with an implied minus sign.
S92 | Direct Connect Transmit Level (default 20) |
Sets the transmit level, in dBm for direct connect. This value may have different settings for different phones.
73