S10

Automatic Disconnect Delay

Range:

1-254

Default:

20

Units:

0.1 seconds

This register sets the length of time, in tenths of a second, that the modem waits before hanging up after a loss of carrier. This allows for a temporary carrier loss without causing the local modem to disconnect. The actual interval the modem waits before disconnecting is the value in register S10.

S11

DTMF Dialing Speed

Range:

50-150

Default:

95

Units:

0.001 seconds

This register determines the dialing speed which is prefixed for each country.

S12

Escape Guard Time

Range:

0-255

Default:

50

Units:

0.02 seconds

This register sets the value (in 20 ms increments) for the required pause after the escape sequence (default 1s).

S14

General Bit Mapped Options Status

Indicates the status of command options. Only bit 2 and bit 5 are used, read only.

Bit 3 Result codes (Vn) 0 = Numeric (V0)

1 = Verbose (Vl) (Default)

Bit 6 Pulse dial PPS selection (&Pn)

0 = 10 PPS (&p0, &p1) (Default)

1 = 20 PPS (&p2)

Default: 8 (00001000b)

68

Image 68
Contents Internal Voice/Fax Windows Modem Table of Contents Introduction For Windows 95 and Windows 98 Installations Do This FirstWindows 95 IRQ Resources Dialog Box COM2 Properties Dialog Box Proceed to the section titled Installing the Modem For Windows NT 4.0 InstallationDevices Window Installing The Modem Hardware InstallationInstalling The Modem Connecting Devices To The Modem Connecting DevicesConfiguring Windows Page Page Configuring Windows 95 OEM SR2 FinishPage Page Page Next Page Page Page Page Page Page Configuring Windows NT Page Page Page AT&F&C1&D2W2 Modem’s Voice FeaturesInit String Page Troubleshooting Windows 95 and WindowsMore Info Panel Does Not Install Uninstalling the ModemPage Page Common Problems No Dialtone ErrorPage AT Commands Repeat Last CommandAnswer Command +++ Escape sequenceCommunication Standard Setting This command determines Ccitt vs. Bell standardResult Codes Carrier ControlDnDial Hook Control Echo CommandOnline Data Character Echo Command Request ID Information Monitor Speaker VolumeThis command sets speaker volume to low, medium, or high This command turns the speaker on or off Modulation HandshakeReturn On-line to Data Mode Select Pulse DialingResult Code Control Select Tone DialingVnDCE Response Format Result Code OptionExtended Result Codes Dial Tone DetectBusy Tone Detect Long Space DisconnectRecall Stored Profile Auto RetrainData Carrier Detect DCD Control DTR Control22bis Guard Tone Control Auxiliary Relay optionAsynchronous Communications Mode This Command is effective only for use in JapanLocal Flow Control Selection Pulse Dial Make-to-Break Ratio SelectionThis command selects DSR action Data Set Ready DSR OptionThis command is used to display the active profiles Below is an example of a possible outputSSE \Bn Zn=x\An \Kn Adjust Bits/s Rate ControlModem Port Flow Control Same as 4.Default \Nn \Tn Inactivity Timer \Vn Protocol Result Code\Xn XON/XOFF Pass Through Data Calling ToneV90=x V.90 Downstream Rate and Control Enable/Disable Data Compression AT Commands for Testing and DebuggingWrite to/Read from DSP Register Line-to-Line LoopbackAfter initial negotiation Tion failedInitial Transmit Carrier Rate 33600 Final Transmit Carrier Rate 33600 RateFinal Receive Carrier Rate 33600 Tion rateRegisters Reference Range 0−255 Default UnitsASCII Range −127, Ascii decimal Default Carriage return UnitsRange −127, Ascii decimal Default Line feed Units Range −32 Default Backspace UnitsComma Dial Modifier Time Range Default UnitssecondsConnection Completion Time-Out S10 Automatic Disconnect Delay S11 Dtmf Dialing SpeedS12 Escape Guard Time S14 General Bit Mapped Options StatusS22 S24 Timer to Control Sleep ModeS21 S28 Modulation Enable/Disable S30 Inactivity TimerS32 S33S37 Dial Line Rate default S38 56K Dial Line Rate defaultS36 ConnectionS42 Auto Rate default 1, range S43 Auto Mode default 1, rangeS48 Lapm Error Control and Feature Negotiation default S40S89 Timer to Control Sleep Mode S90S91 S92Result Code Summary Description No CarrierPage Declaration of Conformity FCC RegulationsFCC Part 68 Requirements Canadian Department Of Communications Cdoc