JVC BR-HD50 manual ESERIAL Remote terminal mini jack, AIEEE1394 IEEE1394 terminal 6P, GFan

Page 12

NAMES AND FUNCTIONS OF PARTS

Rear panel (continued)

e[SERIAL REMOTE] terminal (mini jack)

d

c b a e

a[IEEE1394] IEEE1394 terminal (6P)

This is the input/output terminal for IEEE1394- compliant digital signals.

Inputs HDV signals or DV signals when recording. Digital audio is input simulta- neously.

During playback, it outputs HDV signals, DV signals, and digital audio on the playback tape. Upon analog signal input, EE images and EE audio are output. EE images are DV format signals (480i or 576i) (Only when IEEE1394 switch is set to DV).

This unit records and plays 720p format HDV signals.

720p HDV signals and DV signals from this terminal are recorded as is, without format conversion.

To enable signal input via this terminal, set the INPUT SELECT switch located on the front panel to “HDV/DV”.

The IEEE1394 switch located on the front panel must be set to “HDV” or “DV”, accord- ing to the input signal to this terminal or the video format of the playback tape.

The audio mode (48kHz or 32kHz) cannot be changed for the input audio signal via this terminal. It will be recorded using the input signal audio mode. 4-channel record- ing is possible in the 32kHz audio mode.

Power cannot be supplied via this terminal.

g

hf

To record a time code via this terminal, set TC DUPLI.: DV in the TC/UB/CLOCK [1/2] Menu screen to AUTO or NONDROP. (In DV mode only)

To control this unit via this terminal, set REM SEL HDV/DV in the REMOTE [1/2] Menu screen to ON or LOC/REM.

Note

If HDV/DV signals are not input/output when the IEEE1394 cable is connected, check whether the signal format matches the IEEE1394 switch set- ting on the front panel. If the settings match, either reconnect the IEEE1394 cable, or reset the power to the unit.

bDC power input terminal

This terminal is for inputting DC 12 V. Connect the DC power cord of the supplied AC adapter.

Memo

zWhen power is supplied to this terminal, the OPERATE indicator located on the front panel lights up. (The indicator turns red when BR- HD50 is in the OPERATE OFF state)

zWhether to set BR-HD50 to enter the OPER- ATE ON mode or OPERATE OFF mode when power is supplied to the terminal can be selected with DC IN MODE in the SYSTEM [2/ 2] Menu screen.

This terminal is for connecting to the serial remote controller.

To operate BR-HD50 with this terminal, per- form the following settings.

• Set REMOTE SEL SER in the REMOTE [1/ 2] Menu screen to “ON” or “LOC+REM”.

ON : When the 5 REMOTE/LOCAL switch on the front panel is set to “REMOTE”, this terminal becomes effective.

LOC+REM : This terminal is effective regard- less of the setting of the 5 REMOTE/LOCAL switch on the front panel.

Memo

To use this terminal as the foot switch input, set FOOT SW in the REMOTE [2/2] Menu screen. (XPage 71)

f[REMOTE] RS-422A terminal (D-SUB 9P)

This terminal is for connecting to an RS-422A serial interface-compatible editing remote con- troller (e.g. RM-G820).

With this terminal, BR-HD50 can be used as a player of an editing system.

To operate BR-HD50 with RS-422A, perform the following settings.

Set REMOTE SEL 9P in the REMOTE [1/2] Menu screen to “ON”.

Set the 5 REMOTE/LOCAL switch on the front panel to “REMOTE”.

Memo

Screws for securing connectors differ by region. U model : inch screws

E model : metric screws

gFan

This is a ventilation port for the fan motor. Do not place objects in this area.

hSlot cover for servicing

This is used for servicing the unit.

cDC power cord clamp

Use this clamp to fasten the DC power cord.

d[SIGNAL GND] terminal

This is the grounding terminal for signals.

E-18

E-19

Image 12
Contents For Customer Use BR-HD50HD Video Cassette RecorderBR-HD50U Serial No LLT0088-001AImportant Safeguards InformationRemarque Information for Canada Renseignement Pour CanadaPower System For Your Safety Please Read the Following Text CarefullyMust be Earthed For Continental EUROPE, ETC For U.K. onlyTable of Contents Introduction Remarks of usageCassette tape HDV and DV format Regular maintenance Cleaning tape„ Regular maintenance „ Head cleaningNames and Functions of Parts „ Dvcam indicator light „ 60 indicator light„ 50 indicator light 7COUNTER switchEMENU button HSpecial functions/Setting buttons FRESET button„ BLANK/P button „ SEARCH+/S button DHOLD button GCUE UP button0HDMI OUT Hdmi signal output termi- nal 9CH2/4 Audio OUT terminal RCA2VIDEO Y/C in terminal 4-PIN 3VIDEO Line OUT terminal BNCBDC power input terminal CDC power cord clampDSIGNAL GND terminal ESERIAL Remote terminal mini jackON-SCREEN Display „ DV format„ HDV format VCR operation mode Date/timeCounter display Remaining tapeEvent/Alarm display Display displayed during operation DescriptionDisplay displayed for about 3 seconds Description Display Description„ Output signal „ Input signalConnection Connecting audio signals Attaching the supplied ferrite coreDigital input IEEE1394 terminal 6P „ Operate BR-HD50 with the wired remote controller To the DC cord. XPageRECORDING/OUTPUT Signal Format Component OUTTurning on the power Turning off the power„ Output terminal video/audio signal format during playback PreparationSelecting the operating method main unit/remote controller Operation Lock modeLoading the cassette tape Ejecting the cassette tapeSetting date and time Selecting date/time displayOn-screen status display „ Display Menu screenCheck settings Setting the Menu screenSetting Menu screens RecordingSelecting input signal Tting related Menu screenSettings Adjusting audio recording levelRecording index signals Source unitVideo settings PlaybackAudio settings Settings regarding playback functionFast forward/rewind Slow playback and Search mode Frame-advance playback„ Repeat Mode in the System 1/2 Menu screen Index searchBlank search „ In the Stop mode, press the Blank buttonChanging cue-up points Registering cue-up pointsExiting the Multi Cue-up screen Searching cue-up pointsTime Code „ NDF/DF 60 U model onlyRecording from preset data TCG Select Preset„ Set the TC/UB/CLOCK 1/2 Menu as follows TCG Select RegenControl with RS-422A Analog signals Control with the IEEE1394 ter- minal Digital signalsEdit „ Remote 2/2 Menu screen„ Set BR-HD50 to the Stop or Still mode Setting the menusMenu Screens Menu screen on counter displayTOP Menu screen System Menu screens„ System 1/2 Menu screens „ System 2/2 Menu Remote Menu screens Audio Menu Screen Video Menu ScreenHdmi Mode Test SignalOUT for Down ConvTC/UB/CLOCK Menu screens „ TC/UB/CLOCK 1/2 Menu screen„ TC/UB/CLOCK 2/2 Menu screen „ Alarm display Displayed regardless of the Display mode OthersDisplay Menu screen „ Warning display Displayed regardless of the Display mode „ Set BR-HD50 to the Stop mode „ Connectors „ Accessories„ External dimensions Unit mm „ GeneralImportant Safety Instructions „ AC adapter sectionSupplement