JVC BR-HD50 manual „ Warning display Displayed regardless of the Display mode

Page 43

OTHERS

Warning display (continued)

„Warning display (Displayed regardless of the DISPLAY mode)

When a warning display appears, BR-HD50 stops operation and ceases to accept any operation command. When TAPE DEFECTIVE (5605 - 5609) is displayed, the unit similarly stops all opera- tions except EJECT operation.

Display

Status

Action

WARNING 0201

Condensation.

Leave the power on and wait for the

CONDENSATION ON

 

display to disappear.

DRUM

 

 

 

WARNING 3200

Unable to load tape.

This error can be resolved by turning

LOADING FAILURE

 

off and then on the power. However,

 

 

doing so may damage the tape in

WARNING 3300

Unable to eject tape.

some cases. Consult your JVC

UNLOADING FAILURE

 

 

authorized dealer.

 

 

 

 

 

WARNING 4100

Eject error.

Is a heavy object on the unit?

 

CASSETTE EJECT

 

 

 

FAILURE

 

 

 

DEFECTIVE TAPE!

Broken tape.

Press the EJECT button to remove

5605 - 5609

 

and replace the tape.

WARNING 5702

Tape-end sensor error.

This error can be resolved by turning

TAPE END DET.

 

off and then off the power. However,

ERROR!

 

doing so may damage the tape in

 

 

some cases. Consult your JVC

WARNING 5802

Tape-beginning sensor error.

authorized dealer.

TAPE BEGIN DET.

 

 

 

 

ERROR!

 

 

 

WARNING 7001

Drum rotation error.

 

 

DRUM MOTOR

 

 

 

FAILURE

 

 

 

WARNING 7101

Capstan rotation error.

 

 

CAP MOTOR FAILURE

 

 

 

WARNING 7202 - 7203

Supply reel rotation error.

 

 

SUPPLY REEL

 

 

 

FAILURE

 

 

 

WARNING 7302 - 7303

Take up reel rotation error.

 

 

TAKE UP REEL

 

 

 

FAILURE

 

 

 

WARNING 7305

Tape winding error during unloading.

 

 

TAKE UP REEL

 

 

 

FAILURE

 

 

 

WARNING 7401

Reel motor rotation error.

 

 

REEL MOTOR

 

 

 

FAILURE

 

 

 

Memo

This unit uses a microcomputer. It may not function correctly if there is external noise. If this happens, please turn off the power and then on again.

OTHERS

Troubleshooting

Symptom

Action

 

 

No power.

Is the AC adapter correctly connected?

 

 

Unable to record.

Is the slide of the cassette tape turned to “REC”?

 

Set it to “REC” if it is at the “SAVE” position.

 

 

The operation buttons of BR-HD50

Is OPERATION LOCK of the SYSTEM [2/2] Menu set to ON?

do not work.

Set it to OFF if the operation buttons are to be used.

 

For REMOTE, select the buttons that can be operated with the

 

LOCAL FUNCTION Menu.

 

 

Editing cannot be controlled even

To control with RS-422A, set REMOTE SEL 9P in the REMOTE

after the REMOTE/LOCAL switch

[1/2] Menu screen to “ON”.

is set to REMOTE.

 

Noise is produced on the playback

• The tape is damaged.

video.

Replace the tape.

Playback sound interrupted.

• The head is dirty.

 

Clean it with the specified head-cleaning tape. (XPage 9)

 

 

Cannot play back.

Is the setting for PB TAPE FORMAT in the SYSTEM [2/2] Menu

 

screen something other than AUTO?

 

Playback is not available when this menu item does not match

 

the tape format.

 

 

Time codes are not correctly

Is TC DUPLI.: DV in the TC/UB/CLOCK [1/2] Menu screen cor-

recorded during DV signal input.

rectly set up?

Unable to turn on the power with

Isn’t the REMOTE/LOCAL switch set to REMOTE when

the OPERATE button.

LOCAL FUNCTION in the REMOTE [1/2] Menu screen is not

 

set to ALL KEYS?

 

 

SERIAL REMOTE control does not

Isn’t REMOTE SEL SER in the REMOTE [1/2] Menu screen set

function.

to OFF?

 

For SERIAL REMOTE control, set it to ON or LOC+REM.

 

 

Unable to operate BR-HD50 with

• Isn’t REM SEL HDV/DV in the REMOTE [1/2] Menu screen

the IEEE1394 terminal.

set to OFF? To operate with the IEEE1394 terminal, set it to

 

ON or LOC+REM.

 

• When the controlling equipment (non-linear editor, etc.) does

 

not recognize this unit, either reconnect the IEEE1394

 

cable, or reset the power to the unit.

E-80

E-81

Image 43
Contents Serial No LLT0088-001A For Customer UseBR-HD50HD Video Cassette Recorder BR-HD50UInformation for Canada Renseignement Pour Canada Important SafeguardsInformation RemarqueFor Continental EUROPE, ETC For U.K. only Power SystemFor Your Safety Please Read the Following Text Carefully Must be EarthedTable of Contents Remarks of usage IntroductionCassette tape HDV and DV format „ Head cleaning Regular maintenanceCleaning tape „ Regular maintenanceNames and Functions of Parts 7COUNTER switch „ Dvcam indicator light„ 60 indicator light „ 50 indicator light„ SEARCH+/S button DHOLD button GCUE UP button EMENU button HSpecial functions/Setting buttonsFRESET button „ BLANK/P button3VIDEO Line OUT terminal BNC 0HDMI OUT Hdmi signal output termi- nal9CH2/4 Audio OUT terminal RCA 2VIDEO Y/C in terminal 4-PINESERIAL Remote terminal mini jack BDC power input terminalCDC power cord clamp DSIGNAL GND terminal„ DV format ON-SCREEN Display„ HDV format Remaining tape VCR operation modeDate/time Counter displayDisplay Description Event/Alarm displayDisplay displayed during operation Description Display displayed for about 3 seconds Description„ Input signal „ Output signalConnection Attaching the supplied ferrite core Connecting audio signalsDigital input IEEE1394 terminal 6P To the DC cord. XPage „ Operate BR-HD50 with the wired remote controllerComponent OUT RECORDING/OUTPUT Signal FormatPreparation Turning on the powerTurning off the power „ Output terminal video/audio signal format during playbackEjecting the cassette tape Selecting the operating method main unit/remote controllerOperation Lock mode Loading the cassette tape„ Display Menu screen Setting date and timeSelecting date/time display On-screen status displayRecording Check settingsSetting the Menu screen Setting Menu screensTting related Menu screen Selecting input signalAdjusting audio recording level SettingsSource unit Recording index signalsPlayback Video settingsSettings regarding playback function Audio settingsFast forward/rewind Frame-advance playback Slow playback and Search mode„ In the Stop mode, press the Blank button „ Repeat Mode in the System 1/2 Menu screenIndex search Blank searchSearching cue-up points Changing cue-up pointsRegistering cue-up points Exiting the Multi Cue-up screen„ NDF/DF 60 U model only Time CodeTCG Select Regen Recording from preset dataTCG Select Preset „ Set the TC/UB/CLOCK 1/2 Menu as follows„ Remote 2/2 Menu screen Control with RS-422A Analog signalsControl with the IEEE1394 ter- minal Digital signals EditMenu screen on counter display „ Set BR-HD50 to the Stop or Still modeSetting the menus Menu ScreensSystem Menu screens TOP Menu screen„ System 1/2 Menu screens „ System 2/2 Menu Remote Menu screens Video Menu Screen Audio Menu ScreenDown Conv Hdmi ModeTest Signal OUT for„ TC/UB/CLOCK 1/2 Menu screen TC/UB/CLOCK Menu screens„ TC/UB/CLOCK 2/2 Menu screen Others „ Alarm display Displayed regardless of the Display modeDisplay Menu screen „ Warning display Displayed regardless of the Display mode „ Set BR-HD50 to the Stop mode „ General „ Connectors„ Accessories „ External dimensions Unit mm„ AC adapter section Important Safety InstructionsSupplement