JVC BR-HD50 manual Recording, Check settings, Setting the Menu screen, Setting Menu screens

Page 23

PREPARATION

Selecting HD signal format

On this unit, 60Hz format or 50Hz format for the HD signal format can be selected using 60/50 SEL in the SYSTEM [2/2] Menu screen.

This must be set in the following situations.

zSet to match the input signal format when recording HDV signals from the IEEE1394 terminal.

zSet to match the playback signal format when playing a tape recorded with HDV signals.

RECORDING

Settings for analog signal input

Check settings

Current settings on this unit can be checked by whether the front panel 60 or 50 indicator light is lit.

60 indicator : The HD signal format is 60Hz.

50 indicator : The HD signal format is 50Hz.

INPUT SELECT switch

Setting the Menu screen

Set this using 60/50 SEL in the SYSTEM [2/2] Menu screen. Perform setting while checking the monitor display.

„Press the OPERATE button to turn on the power, and set it to the STOP mode.

1.Press the MENU button to display the TOP Menu screen.

2.Display the SYSTEM Menu screen.

Press the R or P button to move the cursor to SYSTEM, then press SET or the S button.

3.Display the SYSTEM [2/2] Menu screen.

Press the R or P button to move the cursor to NEXT PAGE, then press SET or the S button.

4.Set 60/50 SEL.

1Press the R or P button to move the cursor to 60/50 SEL in the SYSTEM [2/2] Menu screen, then press SET or the S button.

• The setting value area flashes.

2Press the R or P button to select the setting value. 60 : The HD signal format becomes 60Hz.

50 : The HD signal format becomes 50Hz.

3Press the SET or S button confirm the setting value.

„The unit automatically restarts when the setting is confirmed.

Memo

z Recording and playback are unavailable when the unit setting

differs from the HDV input signal or HDV recorded tape signal

format.

SYSTEM [2/2] Menu screen

– – – S Y S T E M [ 2 / 2 ] – – – – – –

D C I N M O D E

O P E O F F

I N D E X W R I T E

I N D E X

O P E R A T I O N L O C K

O N

6 0 / 5 0

S E L

6 0

F A C T O R Y S E T T I N G

C A N C E L

D R U M H O U R M E T E R

0 0 0 0 0 0

P A G E

B A C K

 

„Selecting analog input signal

Set the INPUT SELECT switch located on the front panel to LINE or Y/C.

LINE : Inputs composite video from the LINE IN terminal, and analog audio signals from the AUDIO IN terminal.

Y/C : Inputs Y/C separate signals from the Y/C IN terminal, and analog audio signals from the AUDIO IN terminal.

Setting Menu screens

„Setting VIDEO Menu screen

zSET UP [60]: DV (only for U model)

Set here according to the existence of the setup of analog video signals (composite and Y/C separate). If it exists, set here to ON. If it does not, OFF.

„Setting AUDIO Menu screen

zAUDIO MODE: DV (In DV mode only) Selects the audio sampling frequency for recording.

32k : Records in 12-bit 32kHz mode. DV format has up to four channels of recording tracks available, but this unit only records onto two chan- nels: CH1 and CH2.

48k : Records in 16-bit 48kHz mode. Records onto CH1 and CH2.

„Setting SYSTEM Menu screen

z REC LONG P. TIME

This is for setting the time for BR-HD50 to enter the tape protection mode if there is a long recording pause.

z INDEX WRITE: SYSTEM [2/2] Menu

This is for selecting whether to record index signals automatically when recording starts. (SYSTEM menu details: XPage 67 to 69)

„For settings when recording time codes, refer to pages 60 and 61.

z During DV/analog signal input or when playing a tape recorded

with DV/analog signals, the field frequency format is fixed for

the region, regardless of the 60/50 SEL menu setting.

(U model: 60Hz, E model: 50Hz)

Memo

Audio dubbing is not available on this unit.

E-40

E-41

Image 23
Contents Serial No LLT0088-001A For Customer UseBR-HD50HD Video Cassette Recorder BR-HD50UInformation for Canada Renseignement Pour Canada Important SafeguardsInformation RemarqueFor Continental EUROPE, ETC For U.K. only Power SystemFor Your Safety Please Read the Following Text Carefully Must be EarthedTable of Contents Cassette tape IntroductionRemarks of usage HDV and DV format „ Head cleaning Regular maintenanceCleaning tape „ Regular maintenanceNames and Functions of Parts 7COUNTER switch „ Dvcam indicator light„ 60 indicator light „ 50 indicator light„ SEARCH+/S button DHOLD button GCUE UP button EMENU button HSpecial functions/Setting buttonsFRESET button „ BLANK/P button3VIDEO Line OUT terminal BNC 0HDMI OUT Hdmi signal output termi- nal9CH2/4 Audio OUT terminal RCA 2VIDEO Y/C in terminal 4-PINESERIAL Remote terminal mini jack BDC power input terminalCDC power cord clamp DSIGNAL GND terminal„ HDV format ON-SCREEN Display„ DV format Remaining tape VCR operation modeDate/time Counter displayDisplay Description Event/Alarm displayDisplay displayed during operation Description Display displayed for about 3 seconds DescriptionConnection „ Output signal„ Input signal Digital input IEEE1394 terminal 6P Connecting audio signalsAttaching the supplied ferrite core To the DC cord. XPage „ Operate BR-HD50 with the wired remote controllerComponent OUT RECORDING/OUTPUT Signal FormatPreparation Turning on the powerTurning off the power „ Output terminal video/audio signal format during playbackEjecting the cassette tape Selecting the operating method main unit/remote controllerOperation Lock mode Loading the cassette tape„ Display Menu screen Setting date and timeSelecting date/time display On-screen status displayRecording Check settingsSetting the Menu screen Setting Menu screensTting related Menu screen Selecting input signalAdjusting audio recording level SettingsSource unit Recording index signalsPlayback Video settingsFast forward/rewind Audio settingsSettings regarding playback function Frame-advance playback Slow playback and Search mode„ In the Stop mode, press the Blank button „ Repeat Mode in the System 1/2 Menu screenIndex search Blank searchSearching cue-up points Changing cue-up pointsRegistering cue-up points Exiting the Multi Cue-up screen„ NDF/DF 60 U model only Time CodeTCG Select Regen Recording from preset dataTCG Select Preset „ Set the TC/UB/CLOCK 1/2 Menu as follows„ Remote 2/2 Menu screen Control with RS-422A Analog signalsControl with the IEEE1394 ter- minal Digital signals EditMenu screen on counter display „ Set BR-HD50 to the Stop or Still modeSetting the menus Menu Screens„ System 1/2 Menu screens TOP Menu screenSystem Menu screens „ System 2/2 Menu Remote Menu screens Video Menu Screen Audio Menu ScreenDown Conv Hdmi ModeTest Signal OUT for„ TC/UB/CLOCK 2/2 Menu screen TC/UB/CLOCK Menu screens„ TC/UB/CLOCK 1/2 Menu screen Display Menu screen „ Alarm display Displayed regardless of the Display modeOthers „ Warning display Displayed regardless of the Display mode „ Set BR-HD50 to the Stop mode „ General „ Connectors„ Accessories „ External dimensions Unit mmSupplement Important Safety Instructions„ AC adapter section