JVC BR-HD50 manual Recording index signals, Source unit

Page 26

RECORDING

Recording procedure

2. REC button

2. 4. PLAY button

 

3. PAUSE

 

button

RECORDING

Backup recording function

In combination with DV equipment, BR-HD50 can perform continuous, long-hour recording.

BR-HD50 can be set as the backup unit connected to a DVcamcorder (GY-DV300/DV500/DV550/ DV5000, etc.). When the recording tape of the source unit nears its end, BR-HD50 can start recording, enabling long-hour recording.

Backup unit: BR-HD50

IEEE1394 cable

DV terminal

IEEE1394

terminal

 

INPUT SELECT switch

REMOTE/LOCAL switch

Connection

Connect the DV terminal of the source unit to the IEEE1394 terminal of BR-HD50 with an IEEE1394

„ For using GY-DV5000/DV5100 as the

source unit

Set DV REC TRIGGER in the OTHERS [1/2]

1.Load the cassette tape.

Before loading the cassette tape, please ensure that the rear slide of the cassette tape is pushed to REC.

J The unit is turned on.

2.Start recording.

Press the PLAY button while holding down the REC button.

3.Pause recording.

Press the PAUSE button.

4.Resume recording.

Press the PLAY button.

5.Stop recording.

Press the STOP button.

Memo

zThe tape protection function enables BR-HD50 automati- cally to go into the STOP mode when there is a long recording pause. The time to go into the STOP mode can be set with REC LONG P. TIME in the SYSTEM [1/2] Menu screen.

zWhen a home-use DV VCR is used to play tapes record- ed with BR-HD50, the sound level may be reduced.

cable.

Setting up BR-HD50

„Set the INPUT SELECT switch on the front panel to “HDV/DV”.

„Set the REMOTE/LOCAL switch on the front panel to “REMOTE”.

„Set BACKUP REC: DV in the SYSTEM [1/2] Menu screen.

Use the following settings according to the tape length of the source unit.

*For DV or mini DV cassette tape:

25MIN

: 30-minute tape

55MIN

: 60-minute tape

75MIN

: 80-minute tape

Menu screen of GY-DV5000/DV5100 to OFF.

Operation

1.Recording begins on the source unit.

*Ensure that recording starts from the begin- ning of the recording tape.

2.BR-HD50 begins recording when the tape of the source unit nears its end (about 5 min- utes before the end of the tape).

BR-HD50 begins recording when the record- ing time of the source unit reaches the time set by BACKUP REC: DV.

Memo

z In backup recording, BR-HD50 records video/

sound from the source unit.

While this unit is performing backup recording,

Recording index signals

If INDEX WRITE is set to ON in the SYSTEM [2/2] Menu screen, an index signal is recorded at the recording starting position of the tape. In the PLAYBACK mode, the position where the index signal is recorded can be searched. (Index search)

115MIN

: 120-minute tape

175MIN

: 180-minute tape

265MIN

: 270-minute tape

OFF

: No backup recording

continue shooting from the source unit.

z The audio mode is the one selected in the

source unit. (32 k/48 k)

z Set BACKUP REC: DV to “OFF” if the unit is

„Press the REC button to record index signals during recording.

*It is not possible to record only index signals after the record- ing. Allow at least an interval of 1 minute between recordings of index.

*Index signals cannot be recorded with the REC button of the remote controller. Use the record button of BR-HD50.

Memo

zIf recording is performed right after the RECORDING PAUSE mode is exited, in- dex signals are not record- ed.

„Set the REM SEL HDV/DV in the RE- MOTE [1/2] Menu screen to ON or LOC+REM.

„Set TC DUPLI.: DV in the TC/UB/CLOCK [1/2] Menu screen to OFF.

It records the data of the built-in time code generator.

When TC DUPLI.: DV is set to AUTO or NON DROP, the time code of the DV cam- corder will stop advancing. If the DV cable is disconnected, the time code of the backup recording will stop advancing.

not performing backup recording.

E-46

E-47

Image 26
Contents BR-HD50U For Customer UseBR-HD50HD Video Cassette Recorder Serial No LLT0088-001ARemarque Important SafeguardsInformation Information for Canada Renseignement Pour CanadaMust be Earthed Power SystemFor Your Safety Please Read the Following Text Carefully For Continental EUROPE, ETC For U.K. onlyTable of Contents Cassette tape IntroductionRemarks of usage HDV and DV format „ Regular maintenance Regular maintenanceCleaning tape „ Head cleaningNames and Functions of Parts „ 50 indicator light „ Dvcam indicator light„ 60 indicator light 7COUNTER switch„ BLANK/P button EMENU button HSpecial functions/Setting buttonsFRESET button „ SEARCH+/S button DHOLD button GCUE UP button2VIDEO Y/C in terminal 4-PIN 0HDMI OUT Hdmi signal output termi- nal9CH2/4 Audio OUT terminal RCA 3VIDEO Line OUT terminal BNCDSIGNAL GND terminal BDC power input terminalCDC power cord clamp ESERIAL Remote terminal mini jack„ HDV format ON-SCREEN Display„ DV format Counter display VCR operation modeDate/time Remaining tapeDisplay displayed for about 3 seconds Description Event/Alarm displayDisplay displayed during operation Description Display DescriptionConnection „ Output signal„ Input signal Digital input IEEE1394 terminal 6P Connecting audio signalsAttaching the supplied ferrite core „ Operate BR-HD50 with the wired remote controller To the DC cord. XPageRECORDING/OUTPUT Signal Format Component OUT„ Output terminal video/audio signal format during playback Turning on the powerTurning off the power PreparationLoading the cassette tape Selecting the operating method main unit/remote controllerOperation Lock mode Ejecting the cassette tapeOn-screen status display Setting date and timeSelecting date/time display „ Display Menu screenSetting Menu screens Check settingsSetting the Menu screen RecordingSelecting input signal Tting related Menu screenSettings Adjusting audio recording levelRecording index signals Source unitVideo settings PlaybackFast forward/rewind Audio settingsSettings regarding playback function Slow playback and Search mode Frame-advance playbackBlank search „ Repeat Mode in the System 1/2 Menu screenIndex search „ In the Stop mode, press the Blank buttonExiting the Multi Cue-up screen Changing cue-up pointsRegistering cue-up points Searching cue-up pointsTime Code „ NDF/DF 60 U model only„ Set the TC/UB/CLOCK 1/2 Menu as follows Recording from preset dataTCG Select Preset TCG Select RegenEdit Control with RS-422A Analog signalsControl with the IEEE1394 ter- minal Digital signals „ Remote 2/2 Menu screenMenu Screens „ Set BR-HD50 to the Stop or Still modeSetting the menus Menu screen on counter display„ System 1/2 Menu screens TOP Menu screenSystem Menu screens „ System 2/2 Menu Remote Menu screens Audio Menu Screen Video Menu ScreenOUT for Hdmi ModeTest Signal Down Conv„ TC/UB/CLOCK 2/2 Menu screen TC/UB/CLOCK Menu screens„ TC/UB/CLOCK 1/2 Menu screen Display Menu screen „ Alarm display Displayed regardless of the Display modeOthers „ Warning display Displayed regardless of the Display mode „ Set BR-HD50 to the Stop mode „ External dimensions Unit mm „ Connectors„ Accessories „ GeneralSupplement Important Safety Instructions„ AC adapter section