Acnodes RMC 7132 user manual Installing the Server into the Rack, 1U Rackmount System

Page 20
Installing the Server into the Rack

RMC 7132

1U Rackmount System

Installing the Server into the Rack

You should now have rails attached to both the chassis and the rack unit. The next step is to install the server into the rack. Do this by lining up the rear of the chassis rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting). See Figure 2-3.

When the server has been pushed completely into the rack, you should hear the locking tabs "click".

 

© Copyright 2005 Acnodes, Inc.

661 Brea Canyon Rd., Suite 3

All rights reserved. Product description and product specifications

Walnut, CA 91789

are subject to change without notice. For latest product information,

tel: 909.598.7388, fax: 909.598.0218

please visit Acnodes’ web site at www.acnodes.com.

Image 20
Contents 1U Rackmount System All rights reserved. Product description and product specificationsUser Manual RMC7132 1U Rackmount Computer comes withManual Revision Release Date April 26 Chapter 2 Server Installation Chapter 4 System SafetyPreface Manual OrganizationChapter 5 Advanced Motherboard Setup Chapter 6 Advanced Chassis SetupChapter 7 BIOS Appendix A POST Error Beep Codes Appendix B Installing the Windows OSCHAPTER 2 INSTALLATION CHAPTER 1 INTRODUCTIONTable of Contents 1-3 Server Chassis FeaturesCHAPTER 4 SYSTEM SAFETY CHAPTER 5 ADVANCED MOTHERBOARD SETUPCHAPTER 3 System Interface 2-6 Checking the Drive Bay Setup5-7 Adding PCI Expansion Cards 5-5 Installing the Processor and Heatsink5-6 Installing Memory Modules Serial Ports CHAPTER 6 ADVANCED CHASSIS SETUP CHAPTER 7 BIOSAppendix A POST Error Beep Codes Appendix B Installing the Windows OS Appendix C System SpecificationsCHAPTER 1 INTRODUCTION 1.1 Overview1-2 Motherboard Features Other FeaturesProcessor MemoryAll rights reserved. Product description and product specifications 1-3 Server Chassis Features System PowerSATA Subsystem Control PanelCHAPTER 2 INSTALLATION Choosing a Setup Location2-3 Preparing for Setup 2-1 OverviewRack Precautions Server PrecautionsRack Mounting Considerations Ambient Operating TemperatureReduced Airflow Mechanical Loading2-4 Installing the System into a Rack Identifying the Sections of the Rack RailsInstalling the Chassis Rails Installing the Rack RailsInstalling the Server into the Rack Installing the Server into a Telco Rack 2-5 Checking the Motherboard Setup Checking the ComponentsAll rights reserved. Product description and product specifications 2-6 Checking the Drive Bay Setup Providing PowerChecking the Drives Checking the AirflowReset Button PowerCHAPTER 3 SYSTEM INTERFACE 3-1 OverviewOverheat 3-4 Serial ATA Drive Carrier LEDs CHAPTER 4 SYSTEM SAFETY 4-1 Electrical Safety Precautions4-2 General Safety Precautions 4-3 ESD Precautions 4-4 Operating Precautions 5-1 Handling the Motherboard CHAPTER ADVANCED MOTHERBOARD SETUPPrecautions Unpacking 5-2 Serverboard InstallationInstalling to the Chassis 5-3 Connecting Cables Connecting Data CablesConnecting Power Cables Connecting the Control Panel5-4 I/O Ports 5-5 Installing the Processor and Heatsink Installing an LGA1366 Processor6. Use your thumb to gently push the socket clip down to the clip lock Installing a Passive CPU Heatsink Removing the Heatsink 5-6 Installing Memory Modules Installing & Removing DIMMsTo Install To RemoveMemory Support Maximum Memory PossibleInstalling a PCI Expansion Card 5-7 PCI Expansion Cards5-8 Serverboard Details All rights reserved. Product description and product specifications 5-9 Connector Definitions Main ATX Power Supply ConnectorProcessor Power Connector Power ButtonHDD LED/UID Switch Power On LEDOverheat/Fan Fail/UID LED NIC2 LAN2 LEDNMI Button Fan HeadersATX PS/2 Keyboard and PS/2 Mouse Ports Serial PortsOnboard Power LED Chassis IntrusionWake-On-LAN External Speaker/Internal BuzzerPower Supply SMBus Header Universal Serial Bus USBSGPIO Headers LAN1/2 Ethernet PortsPower Supply Fail LED Header Alarm ResetI-Button Unit Identifier Button5-10 Jumper Settings VGA Enable/DisableExplanation of Jumpers CMOS ClearUSB Wake-Up LAN1/2 Enable/DisableWatch Dog Enable/Disable 5-11 Onboard Indicators BMC Enable/DisableSMBus to PCI Slots LAN1/2 LEDsAll rights reserved. Product description and product specifications 1U Rackmount SystemCopyright 2005 Acnodes, Inc 661 Brea Canyon Rd., SuiteAll rights reserved. Product description and product specifications 5-13 Installing Software Driver/Tool Installation Display ScreenDoctor All rights reserved. Product description and product specifications Tools Required CHAPTER 6 ADVANCED CHASSIS SETUP6-1 Static-Sensitive Devices 6-2 Control Panel Replacing System Cooling Fans 6-3 System FansSystem Fan Failure SATA Drive Installation 6-4 Drive Bay Installation/RemovalAccessing the Drive Bays Installing/Removing SATA Drives Mounting a SATA Drive in a Drive CarrierInstalling a DVD-ROM Drive SATA Power CablesDVD-ROM Drive Installation Replacing the Power Supply 6-5 Power SupplyPower Supply Failure CHAPTER 7 BIOS Starting BIOS Setup UtilityHow To Change the Configuration Data 7-1 Introduction7-2 Main Setup Starting the Setup UtilitySystem Overview The following BIOS information will be displayed System Time/System DateSystem Memory 7-3 Advanced Setup Configurations XBIOS Features Quick BootQuiet Boot Bootup Num-LockWait For F1 If Error Power Button FunctionRestore on AC Power Loss PS/2 Mouse SupportRatio CMOS Setting Hardware Prefetcher Available when supported by the CPUAdjacent Cache Line Prefetch Available when supported by the CPU XProcessor & Clock OptionsIntel Virtualization Technology Available when supported by the CPU Simultaneous Multi-Threading Available when supported by the CPUIntel TurboMode Tech Available if Intel EIST technology is Enabled Intel EIST TechnologyIntel Turbo Boost Configuration Turbo Ratio Limit Program 1 - Core Ratio Limit2 ~ 3 - Core Ratio Limit TDC Limit OverrideC-State package limit setting XAdvanced Chipset ControlC-STATE Tech C1 Auto DemotionQPI L0s and L1 Memory FrequencyMemory Mode Demand ScrubbingHigh Performance Event Timer Inlet TemperatureTemperature Rise Air FlowActive State Power Management Intel VT-dIntel I/OAT USB FunctionsXIDE / Floppy Configuration SATA#1 ConfigurationConfigure SATA#1 as IDE Detect Timeout secType LBA/Large ModeBlock Multi-Sector Transfer PIO Mode32Bit Data Transfer DMA ModeS.M.A.R.T. For Hard disk drives XPCI/PnP Configuration PCI Latency TimerClear NVRAM Plug & Play OSXSuper IO Device Configuration XRemote Access ConfigurationRemote Access Serial Port1 Address/ Serial Port2 AddressXHardware Health Configuration Redirection After BIOS POSTCPU Overheat Alarm Terminal TypeThe item displays the absolute temperature as detected by the BIOS CPU TemperatureSystem Temperature XACPI Configuration ACPI Version FeaturesFan Speed Control Modes Fan1 ~ Fan 5 ReadingXIPMI Configuration Execute TPM CommandTPM Enable/Disable Status XTrusted ComputingClear BMC System Event Log Set LAN ConfigurationSet PEF Configuration XEvent Log Configuration BMC Watch Dog Timer ActionBMC WatchDog TimeOut MinSec View Event Log7-4 Security Settings Supervisor PasswordUser Password Change Supervisor PasswordChange User Password Boot Sector Virus ProtectionXHard Disk Drives 7-5 Boot SettingsXBoot Device Priority 7-6 Exit Options XRemovable DrivesXCD/DVD Drives Save Changes and ExitLoad Optimal Defaults Load Fail-Safe DefaultsDiscard Changes and Exit Discard ChangesAppendix A POST Error Beep Codes Recoverable POST Error Beep CodesAppendix B Installing the Windows OS B-1 Installing Windows on RAID SystemsB-2 Installing Windows on Non-RAID Systems Appendix C Specifications BIOSProcessors ChipsetWeight Power SupplySystem Input Requirements Operating Environment