RMC 7132
1U Rackmount System
Inlet Temperature
This is the temperature detected at the chassis inlet. Each step is in 0.5oC increment. The default is [070]. Press "+" or
Temperature Rise
This item allows the user to define the temperature rise parameter of a memory module to be used to improve memory power management. Each setting is in
0.5oC increments. The default setting is [020]. Press "+" or
to change this value.
Air Flow
This item allows the user to set the desired speed of air flow to the DIMM mod- ules. Each increment is one mm/sec. The default is [1500]. Press "+" or
Altitude
This item allows the user to specify the altitude of the location where the com- puter is used. For
901~1200
DIMM Pitch
Use this feature to specify the distance of physical space between each DIMM module. Each step is in 1/1000 of an inch. The default is [400]. Press "+" or
High Performance Event Timer
Select Enabled to activate the High Performance Event Timer (HPET) that produces periodic inter- rupts at a much higher frequency than a