Acnodes RMC 7132 XIDE / Floppy Configuration, Floppy A, SATA#1 Configuration, Configure SATA#1 as

Page 78
XIDE / Floppy Configuration

RMC 7132

1U Rackmount System

XIDE / Floppy Configuration

When this submenu is selected, the AMI BIOS automatically detects the presence of the IDE Devices and displays the following items:

Floppy A

This feature allows the user to select the type of floppy drive connected to the sys- tem. The options are Disabled, 360KB 5 1/4", 1.2MB 5 1/4", 720KB 3 1/2", 1.44MB

3 1/2" and 2.88MB 3 1/2".

SATA#1 Configuration

If Compatible is selected, it sets SATA#1 to legacy compatibility mode, while se- lecting Enhanced sets SATA#1 to native SATA mode. The options are Disabled, Compatible, Enhanced.

Configure SATA#1 as

This feature allows the user to select the drive type for SATA#1. The options are IDE, RAID and AHCI.

ICH RAID CodeBase (Available if RAID is selected above)

Select Intel to enable the Intel SATA Host RAID Utility. Select Adaptec to use the Adaptec Host RAID Utility. The options are Intel and Adaptec.

Max Ports on SATA#1 (Available if either RAID or AHCI is enabled under "Configure SATA#1 as" above)

This feature specifies how many ports are active on SATA #1. The options are 4 Ports and 6 Ports. SATA#2 Configuration (Available if IDE is enabled under "Configure SATA#1 as" above) Selecting Enhanced will set SATA#2 to native SATA mode. The options are

Disabled, Enhanced

IDE Detect Timeout (sec)

Use this feature to set the time-out value for the BIOS to detect the ATA, ATAPI

devices installed in the system. The options are 0 (sec), 5, 10, 15, 20, 25, 30, and 35.

Primary IDE Master/Slave, Secondary IDE Master/Slave, Third IDE Master, and Fourth IDE Master

These settings allow the user to set the parameters of Primary IDE Master/Slave, Secondary IDE Master/Slave, Third and Fourth IDE Master slots. Hit <Enter> to

 

© Copyright 2005 Acnodes, Inc.

661 Brea Canyon Rd., Suite 3

All rights reserved. Product description and product specifications

Walnut, CA 91789

are subject to change without notice. For latest product information,

tel: 909.598.7388, fax: 909.598.0218

please visit Acnodes’ web site at www.acnodes.com.

Image 78
Contents User Manual 1U Rackmount SystemAll rights reserved. Product description and product specifications RMC7132 1U Rackmount Computer comes withManual Revision Release Date April 26 Preface Chapter 2 Server InstallationChapter 4 System Safety Manual OrganizationChapter 7 BIOS Chapter 5 Advanced Motherboard SetupChapter 6 Advanced Chassis Setup Appendix A POST Error Beep Codes Appendix B Installing the Windows OSTable of Contents CHAPTER 2 INSTALLATIONCHAPTER 1 INTRODUCTION 1-3 Server Chassis FeaturesCHAPTER 3 System Interface CHAPTER 4 SYSTEM SAFETYCHAPTER 5 ADVANCED MOTHERBOARD SETUP 2-6 Checking the Drive Bay Setup5-5 Installing the Processor and Heatsink 5-6 Installing Memory Modules5-7 Adding PCI Expansion Cards Serial Ports CHAPTER 6 ADVANCED CHASSIS SETUP CHAPTER 7 BIOSAppendix A POST Error Beep Codes Appendix B Installing the Windows OS Appendix C System SpecificationsCHAPTER 1 INTRODUCTION 1.1 OverviewProcessor 1-2 Motherboard FeaturesOther Features MemoryCopyright 2009 Acnodes, Inc SATA Subsystem 1-3 Server Chassis FeaturesSystem Power Control Panel2-3 Preparing for Setup CHAPTER 2 INSTALLATIONChoosing a Setup Location 2-1 OverviewRack Precautions Server PrecautionsReduced Airflow Rack Mounting ConsiderationsAmbient Operating Temperature Mechanical Loading2-4 Installing the System into a Rack Identifying the Sections of the Rack RailsInstalling the Chassis Rails Installing the Rack RailsInstalling the Server into the Rack Installing the Server into a Telco Rack 2-5 Checking the Motherboard Setup Checking the ComponentsCopyright 2009 Acnodes, Inc Checking the Drives 2-6 Checking the Drive Bay SetupProviding Power Checking the AirflowCHAPTER 3 SYSTEM INTERFACE Reset ButtonPower 3-1 OverviewOverheat 3-4 Serial ATA Drive Carrier LEDs CHAPTER 4 SYSTEM SAFETY 4-1 Electrical Safety Precautions4-2 General Safety Precautions 4-3 ESD Precautions 4-4 Operating Precautions CHAPTER ADVANCED MOTHERBOARD SETUP Precautions5-1 Handling the Motherboard 5-2 Serverboard Installation Installing to the ChassisUnpacking Connecting Power Cables 5-3 Connecting CablesConnecting Data Cables Connecting the Control Panel5-4 I/O Ports 5-5 Installing the Processor and Heatsink Installing an LGA1366 Processor6. Use your thumb to gently push the socket clip down to the clip lock Installing a Passive CPU Heatsink Removing the Heatsink To Install 5-6 Installing Memory ModulesInstalling & Removing DIMMs To RemoveMemory Support Maximum Memory PossibleInstalling a PCI Expansion Card 5-7 PCI Expansion Cards5-8 Serverboard Details Copyright 2005 Acnodes, Inc Processor Power Connector 5-9 Connector DefinitionsMain ATX Power Supply Connector Power ButtonOverheat/Fan Fail/UID LED HDD LED/UID SwitchPower On LED NIC2 LAN2 LEDATX PS/2 Keyboard and PS/2 Mouse Ports NMI ButtonFan Headers Serial PortsWake-On-LAN Onboard Power LEDChassis Intrusion External Speaker/Internal BuzzerSGPIO Headers Power Supply SMBus HeaderUniversal Serial Bus USB LAN1/2 Ethernet PortsI-Button Power Supply Fail LED HeaderAlarm Reset Unit Identifier ButtonExplanation of Jumpers 5-10 Jumper SettingsVGA Enable/Disable CMOS ClearLAN1/2 Enable/Disable Watch Dog Enable/DisableUSB Wake-Up SMBus to PCI Slots 5-11 Onboard IndicatorsBMC Enable/Disable LAN1/2 LEDsCopyright 2005 Acnodes, Inc All rights reserved. Product description and product specifications1U Rackmount System 661 Brea Canyon Rd., SuiteCopyright 2009 Acnodes, Inc 5-13 Installing Software Driver/Tool Installation Display ScreenDoctor Copyright 2005 Acnodes, Inc CHAPTER 6 ADVANCED CHASSIS SETUP 6-1 Static-Sensitive DevicesTools Required 6-2 Control Panel 6-3 System Fans System Fan FailureReplacing System Cooling Fans 6-4 Drive Bay Installation/Removal Accessing the Drive BaysSATA Drive Installation Installing/Removing SATA Drives Mounting a SATA Drive in a Drive CarrierSATA Power Cables DVD-ROM Drive InstallationInstalling a DVD-ROM Drive 6-5 Power Supply Power Supply FailureReplacing the Power Supply How To Change the Configuration Data CHAPTER 7 BIOSStarting BIOS Setup Utility 7-1 Introduction7-2 Main Setup Starting the Setup UtilitySystem Time/System Date System MemorySystem Overview The following BIOS information will be displayed Quiet Boot 7-3 Advanced Setup ConfigurationsXBIOS Features Quick Boot Bootup Num-LockRestore on AC Power Loss Wait For F1 If ErrorPower Button Function PS/2 Mouse SupportAdjacent Cache Line Prefetch Available when supported by the CPU Ratio CMOS SettingHardware Prefetcher Available when supported by the CPU XProcessor & Clock OptionsIntel TurboMode Tech Available if Intel EIST technology is Enabled Intel Virtualization Technology Available when supported by the CPUSimultaneous Multi-Threading Available when supported by the CPU Intel EIST Technology2 ~ 3 - Core Ratio Limit Intel Turbo Boost Configuration Turbo Ratio Limit Program1 - Core Ratio Limit TDC Limit OverrideC-STATE Tech C-State package limit settingXAdvanced Chipset Control C1 Auto DemotionMemory Mode QPI L0s and L1Memory Frequency Demand ScrubbingTemperature Rise High Performance Event TimerInlet Temperature Air FlowIntel I/OAT Active State Power ManagementIntel VT-d USB FunctionsConfigure SATA#1 as XIDE / Floppy ConfigurationSATA#1 Configuration IDE Detect Timeout secBlock Multi-Sector Transfer TypeLBA/Large Mode PIO ModeDMA Mode S.M.A.R.T. For Hard disk drives32Bit Data Transfer Clear NVRAM XPCI/PnP ConfigurationPCI Latency Timer Plug & Play OSRemote Access XSuper IO Device ConfigurationXRemote Access Configuration Serial Port1 Address/ Serial Port2 AddressCPU Overheat Alarm XHardware Health ConfigurationRedirection After BIOS POST Terminal TypeCPU Temperature System TemperatureThe item displays the absolute temperature as detected by the BIOS Fan Speed Control Modes XACPI ConfigurationACPI Version Features Fan1 ~ Fan 5 ReadingTPM Enable/Disable Status XIPMI ConfigurationExecute TPM Command XTrusted ComputingSet LAN Configuration Set PEF ConfigurationClear BMC System Event Log BMC WatchDog TimeOut MinSec XEvent Log ConfigurationBMC Watch Dog Timer Action View Event LogUser Password 7-4 Security SettingsSupervisor Password Change Supervisor PasswordChange User Password Boot Sector Virus Protection7-5 Boot Settings XBoot Device PriorityXHard Disk Drives XCD/DVD Drives 7-6 Exit OptionsXRemovable Drives Save Changes and ExitDiscard Changes and Exit Load Optimal DefaultsLoad Fail-Safe Defaults Discard ChangesAppendix A POST Error Beep Codes Recoverable POST Error Beep CodesAppendix B Installing the Windows OS B-1 Installing Windows on RAID SystemsB-2 Installing Windows on Non-RAID Systems Processors Appendix C SpecificationsBIOS ChipsetSystem Input Requirements WeightPower Supply Operating Environment