Acnodes RMC 7132 Appendix B Installing the Windows OS, B-1 Installing Windows on RAID Systems

Page 95
Appendix B Installing the Windows OS

RMC 7132

1U Rackmount System

Appendix B Installing the Windows OS

After all hardware components have been installed, you must first configure Intel South Bridge RAID Settings before you install the Windows OS and other software drivers. To configure RAID settings, please refer to RAID Configuration User Guides posted on our website at www.supermicro.com/ support/manuals.

Please note that the Intel ICH10R South Bridge used on this motherboard does not support HostRAID settings.

B-1 Installing Windows on RAID Systems

1.Insert Microsoft's Windows XP/2003 Setup CD in the CD drive and the sys- tem will start booting up from CD.

2.Press the <F6> key when the message "Press F6 if you need to install a third party SCSI or RAID driver" displays.

3.When the Windows XP/2003 Setup screen appears, press "S" to specify ad- ditional device(s).

4.Insert the driver diskette "Intel AA RAID XP/2003 Driver for ICH10R" into

Drive A: and press the <Enter> key.

5.Choose the Intel(R) ICH10R SATA RAID Controller from the list indicated in the XP/2003 Setup Screen and press the <Enter> key.

6.Press the <Enter> key to continue the installation process. (If you need to specify any additional devices to be installed, do it at this time.) Once all devices are specified, press the <Enter> key to continue with the installation.

7.From the Windows XP/2003 Setup screen, press the <Enter> key. The XP/2003 Setup will auto- matically load all device files and then continue installing Windows.

8.After the Windows XP/2003 OS installation is complete, the system will auto- matically reboot.

 

© Copyright 2009 Acnodes, Inc.

661 Brea Canyon Rd., Suite 3

All rights reserved. Product description and product specifications

Walnut, CA 91789

are subject to change without notice. For latest product information,

tel: 909.598.7388, fax: 909.598.0218

please visit Acnodes’ web site at www.acnodes.com.

Image 95
Contents RMC7132 1U Rackmount Computer comes with 1U Rackmount SystemAll rights reserved. Product description and product specifications User ManualManual Revision Release Date April 26 Manual Organization Chapter 2 Server InstallationChapter 4 System Safety PrefaceAppendix A POST Error Beep Codes Appendix B Installing the Windows OS Chapter 5 Advanced Motherboard SetupChapter 6 Advanced Chassis Setup Chapter 7 BIOS1-3 Server Chassis Features CHAPTER 2 INSTALLATIONCHAPTER 1 INTRODUCTION Table of Contents2-6 Checking the Drive Bay Setup CHAPTER 4 SYSTEM SAFETYCHAPTER 5 ADVANCED MOTHERBOARD SETUP CHAPTER 3 System Interface5-7 Adding PCI Expansion Cards 5-5 Installing the Processor and Heatsink5-6 Installing Memory Modules Serial Ports CHAPTER 7 BIOS CHAPTER 6 ADVANCED CHASSIS SETUPAppendix C System Specifications Appendix A POST Error Beep Codes Appendix B Installing the Windows OS1.1 Overview CHAPTER 1 INTRODUCTIONMemory 1-2 Motherboard FeaturesOther Features Processor661 Brea Canyon Rd., Suite Control Panel 1-3 Server Chassis FeaturesSystem Power SATA Subsystem2-1 Overview CHAPTER 2 INSTALLATIONChoosing a Setup Location 2-3 Preparing for SetupServer Precautions Rack PrecautionsMechanical Loading Rack Mounting ConsiderationsAmbient Operating Temperature Reduced AirflowIdentifying the Sections of the Rack Rails 2-4 Installing the System into a RackInstalling the Rack Rails Installing the Chassis RailsInstalling the Server into the Rack Installing the Server into a Telco Rack Checking the Components 2-5 Checking the Motherboard Setup661 Brea Canyon Rd., Suite Checking the Airflow 2-6 Checking the Drive Bay SetupProviding Power Checking the Drives3-1 Overview Reset ButtonPower CHAPTER 3 SYSTEM INTERFACEOverheat 3-4 Serial ATA Drive Carrier LEDs 4-1 Electrical Safety Precautions CHAPTER 4 SYSTEM SAFETY4-2 General Safety Precautions 4-3 ESD Precautions 4-4 Operating Precautions 5-1 Handling the Motherboard CHAPTER ADVANCED MOTHERBOARD SETUPPrecautions Unpacking 5-2 Serverboard InstallationInstalling to the Chassis Connecting the Control Panel 5-3 Connecting CablesConnecting Data Cables Connecting Power Cables5-4 I/O Ports Installing an LGA1366 Processor 5-5 Installing the Processor and Heatsink6. Use your thumb to gently push the socket clip down to the clip lock Installing a Passive CPU Heatsink Removing the Heatsink To Remove 5-6 Installing Memory ModulesInstalling & Removing DIMMs To InstallMaximum Memory Possible Memory Support5-7 PCI Expansion Cards Installing a PCI Expansion Card5-8 Serverboard Details 661 Brea Canyon Rd., Suite Power Button 5-9 Connector DefinitionsMain ATX Power Supply Connector Processor Power ConnectorNIC2 LAN2 LED HDD LED/UID SwitchPower On LED Overheat/Fan Fail/UID LEDSerial Ports NMI ButtonFan Headers ATX PS/2 Keyboard and PS/2 Mouse PortsExternal Speaker/Internal Buzzer Onboard Power LEDChassis Intrusion Wake-On-LANLAN1/2 Ethernet Ports Power Supply SMBus HeaderUniversal Serial Bus USB SGPIO HeadersUnit Identifier Button Power Supply Fail LED HeaderAlarm Reset I-ButtonCMOS Clear 5-10 Jumper SettingsVGA Enable/Disable Explanation of JumpersUSB Wake-Up LAN1/2 Enable/DisableWatch Dog Enable/Disable LAN1/2 LEDs 5-11 Onboard IndicatorsBMC Enable/Disable SMBus to PCI Slots661 Brea Canyon Rd., Suite All rights reserved. Product description and product specifications1U Rackmount System Copyright 2005 Acnodes, Inc661 Brea Canyon Rd., Suite Driver/Tool Installation Display Screen 5-13 Installing SoftwareDoctor 661 Brea Canyon Rd., Suite Tools Required CHAPTER 6 ADVANCED CHASSIS SETUP6-1 Static-Sensitive Devices 6-2 Control Panel Replacing System Cooling Fans 6-3 System FansSystem Fan Failure SATA Drive Installation 6-4 Drive Bay Installation/RemovalAccessing the Drive Bays Mounting a SATA Drive in a Drive Carrier Installing/Removing SATA DrivesInstalling a DVD-ROM Drive SATA Power CablesDVD-ROM Drive Installation Replacing the Power Supply 6-5 Power SupplyPower Supply Failure 7-1 Introduction CHAPTER 7 BIOSStarting BIOS Setup Utility How To Change the Configuration DataStarting the Setup Utility 7-2 Main SetupSystem Overview The following BIOS information will be displayed System Time/System DateSystem Memory Bootup Num-Lock 7-3 Advanced Setup ConfigurationsXBIOS Features Quick Boot Quiet BootPS/2 Mouse Support Wait For F1 If ErrorPower Button Function Restore on AC Power LossXProcessor & Clock Options Ratio CMOS SettingHardware Prefetcher Available when supported by the CPU Adjacent Cache Line Prefetch Available when supported by the CPUIntel EIST Technology Intel Virtualization Technology Available when supported by the CPUSimultaneous Multi-Threading Available when supported by the CPU Intel TurboMode Tech Available if Intel EIST technology is EnabledTDC Limit Override Intel Turbo Boost Configuration Turbo Ratio Limit Program1 - Core Ratio Limit 2 ~ 3 - Core Ratio LimitC1 Auto Demotion C-State package limit settingXAdvanced Chipset Control C-STATE TechDemand Scrubbing QPI L0s and L1Memory Frequency Memory ModeAir Flow High Performance Event TimerInlet Temperature Temperature RiseUSB Functions Active State Power ManagementIntel VT-d Intel I/OATIDE Detect Timeout sec XIDE / Floppy ConfigurationSATA#1 Configuration Configure SATA#1 asPIO Mode TypeLBA/Large Mode Block Multi-Sector Transfer32Bit Data Transfer DMA ModeS.M.A.R.T. For Hard disk drives Plug & Play OS XPCI/PnP ConfigurationPCI Latency Timer Clear NVRAMSerial Port1 Address/ Serial Port2 Address XSuper IO Device ConfigurationXRemote Access Configuration Remote AccessTerminal Type XHardware Health ConfigurationRedirection After BIOS POST CPU Overheat AlarmThe item displays the absolute temperature as detected by the BIOS CPU TemperatureSystem Temperature Fan1 ~ Fan 5 Reading XACPI ConfigurationACPI Version Features Fan Speed Control ModesXTrusted Computing XIPMI ConfigurationExecute TPM Command TPM Enable/Disable StatusClear BMC System Event Log Set LAN ConfigurationSet PEF Configuration View Event Log XEvent Log ConfigurationBMC Watch Dog Timer Action BMC WatchDog TimeOut MinSecChange Supervisor Password 7-4 Security SettingsSupervisor Password User PasswordBoot Sector Virus Protection Change User PasswordXHard Disk Drives 7-5 Boot SettingsXBoot Device Priority Save Changes and Exit 7-6 Exit OptionsXRemovable Drives XCD/DVD DrivesDiscard Changes Load Optimal DefaultsLoad Fail-Safe Defaults Discard Changes and ExitRecoverable POST Error Beep Codes Appendix A POST Error Beep CodesB-1 Installing Windows on RAID Systems Appendix B Installing the Windows OSB-2 Installing Windows on Non-RAID Systems Chipset Appendix C SpecificationsBIOS ProcessorsOperating Environment WeightPower Supply System Input Requirements