Acnodes RMC 7132 Advanced Chassis Setup, Static-Sensitive Devices, Tools Required, Precautions

Page 59
CHAPTER 6 ADVANCED CHASSIS SETUP

RMC 7132

1U Rackmount System

CHAPTER 6 ADVANCED CHASSIS SETUP

This chapter covers the steps required to install components and perform main- tenance on the SC512C-250 chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If a step is unnecessary, skip ahead to the step that follows.

Tools Required

The only tool you will need to install components and perform maintenance is a Philips screwdriver.

6-1 Static-Sensitive Devices

Electrostatic Discharge (ESD) can damage electronic components. To prevent damage to any printed circuit boards (PCBs), it is important to handle them very carefully. The following measures are generally sufficient to protect your equipment from ESD discharge.

Precautions

o Use a grounded wrist strap designed to prevent static discharge.

o Touch a grounded metal object before removing any board from its antistatic bag.

o Handle a board by its edges only; do not touch its components, peripheral chips, memory modules or gold contacts.

o When handling chips or modules, avoid touching their pins.

o Put the serverboard, add-on cards and peripherals back into their antistatic bags when not in use.

o For grounding purposes, make sure your computer chassis provides excellent conductivity between the power supply, the case, the mounting fasteners and the serverboard.

 

© Copyright 2009 Acnodes, Inc.

661 Brea Canyon Rd., Suite 3

All rights reserved. Product description and product specifications

Walnut, CA 91789

are subject to change without notice. For latest product information,

tel: 909.598.7388, fax: 909.598.0218

please visit Acnodes’ web site at www.acnodes.com.

Image 59
Contents RMC7132 1U Rackmount Computer comes with 1U Rackmount SystemAll rights reserved. Product description and product specifications User ManualManual Revision Release Date April 26 Manual Organization Chapter 2 Server InstallationChapter 4 System Safety PrefaceAppendix A POST Error Beep Codes Appendix B Installing the Windows OS Chapter 5 Advanced Motherboard SetupChapter 6 Advanced Chassis Setup Chapter 7 BIOS1-3 Server Chassis Features CHAPTER 2 INSTALLATIONCHAPTER 1 INTRODUCTION Table of Contents2-6 Checking the Drive Bay Setup CHAPTER 4 SYSTEM SAFETYCHAPTER 5 ADVANCED MOTHERBOARD SETUP CHAPTER 3 System Interface5-7 Adding PCI Expansion Cards 5-5 Installing the Processor and Heatsink5-6 Installing Memory Modules Serial Ports CHAPTER 7 BIOS CHAPTER 6 ADVANCED CHASSIS SETUPAppendix C System Specifications Appendix A POST Error Beep Codes Appendix B Installing the Windows OS1.1 Overview CHAPTER 1 INTRODUCTIONMemory 1-2 Motherboard FeaturesOther Features Processor661 Brea Canyon Rd., Suite Control Panel 1-3 Server Chassis FeaturesSystem Power SATA Subsystem2-1 Overview CHAPTER 2 INSTALLATIONChoosing a Setup Location 2-3 Preparing for SetupServer Precautions Rack PrecautionsMechanical Loading Rack Mounting ConsiderationsAmbient Operating Temperature Reduced AirflowIdentifying the Sections of the Rack Rails 2-4 Installing the System into a RackInstalling the Rack Rails Installing the Chassis RailsInstalling the Server into the Rack Installing the Server into a Telco Rack Checking the Components 2-5 Checking the Motherboard Setup661 Brea Canyon Rd., Suite Checking the Airflow 2-6 Checking the Drive Bay SetupProviding Power Checking the Drives3-1 Overview Reset ButtonPower CHAPTER 3 SYSTEM INTERFACEOverheat 3-4 Serial ATA Drive Carrier LEDs 4-1 Electrical Safety Precautions CHAPTER 4 SYSTEM SAFETY4-2 General Safety Precautions 4-3 ESD Precautions 4-4 Operating Precautions 5-1 Handling the Motherboard CHAPTER ADVANCED MOTHERBOARD SETUPPrecautions Unpacking 5-2 Serverboard InstallationInstalling to the Chassis Connecting the Control Panel 5-3 Connecting CablesConnecting Data Cables Connecting Power Cables5-4 I/O Ports Installing an LGA1366 Processor 5-5 Installing the Processor and Heatsink6. Use your thumb to gently push the socket clip down to the clip lock Installing a Passive CPU Heatsink Removing the Heatsink To Remove 5-6 Installing Memory ModulesInstalling & Removing DIMMs To InstallMaximum Memory Possible Memory Support5-7 PCI Expansion Cards Installing a PCI Expansion Card5-8 Serverboard Details 661 Brea Canyon Rd., Suite Power Button 5-9 Connector DefinitionsMain ATX Power Supply Connector Processor Power ConnectorNIC2 LAN2 LED HDD LED/UID SwitchPower On LED Overheat/Fan Fail/UID LEDSerial Ports NMI ButtonFan Headers ATX PS/2 Keyboard and PS/2 Mouse PortsExternal Speaker/Internal Buzzer Onboard Power LEDChassis Intrusion Wake-On-LANLAN1/2 Ethernet Ports Power Supply SMBus HeaderUniversal Serial Bus USB SGPIO HeadersUnit Identifier Button Power Supply Fail LED HeaderAlarm Reset I-ButtonCMOS Clear 5-10 Jumper SettingsVGA Enable/Disable Explanation of JumpersUSB Wake-Up LAN1/2 Enable/DisableWatch Dog Enable/Disable LAN1/2 LEDs 5-11 Onboard IndicatorsBMC Enable/Disable SMBus to PCI Slots661 Brea Canyon Rd., Suite All rights reserved. Product description and product specifications1U Rackmount System Copyright 2005 Acnodes, Inc661 Brea Canyon Rd., Suite Driver/Tool Installation Display Screen 5-13 Installing SoftwareDoctor 661 Brea Canyon Rd., Suite Tools Required CHAPTER 6 ADVANCED CHASSIS SETUP6-1 Static-Sensitive Devices 6-2 Control Panel Replacing System Cooling Fans 6-3 System FansSystem Fan Failure SATA Drive Installation 6-4 Drive Bay Installation/RemovalAccessing the Drive Bays Mounting a SATA Drive in a Drive Carrier Installing/Removing SATA DrivesInstalling a DVD-ROM Drive SATA Power CablesDVD-ROM Drive Installation Replacing the Power Supply 6-5 Power SupplyPower Supply Failure 7-1 Introduction CHAPTER 7 BIOSStarting BIOS Setup Utility How To Change the Configuration DataStarting the Setup Utility 7-2 Main SetupSystem Overview The following BIOS information will be displayed System Time/System DateSystem Memory Bootup Num-Lock 7-3 Advanced Setup ConfigurationsXBIOS Features Quick Boot Quiet BootPS/2 Mouse Support Wait For F1 If ErrorPower Button Function Restore on AC Power LossXProcessor & Clock Options Ratio CMOS SettingHardware Prefetcher Available when supported by the CPU Adjacent Cache Line Prefetch Available when supported by the CPUIntel EIST Technology Intel Virtualization Technology Available when supported by the CPUSimultaneous Multi-Threading Available when supported by the CPU Intel TurboMode Tech Available if Intel EIST technology is EnabledTDC Limit Override Intel Turbo Boost Configuration Turbo Ratio Limit Program1 - Core Ratio Limit 2 ~ 3 - Core Ratio LimitC1 Auto Demotion C-State package limit settingXAdvanced Chipset Control C-STATE TechDemand Scrubbing QPI L0s and L1Memory Frequency Memory ModeAir Flow High Performance Event TimerInlet Temperature Temperature RiseUSB Functions Active State Power ManagementIntel VT-d Intel I/OATIDE Detect Timeout sec XIDE / Floppy ConfigurationSATA#1 Configuration Configure SATA#1 asPIO Mode TypeLBA/Large Mode Block Multi-Sector Transfer32Bit Data Transfer DMA ModeS.M.A.R.T. For Hard disk drives Plug & Play OS XPCI/PnP ConfigurationPCI Latency Timer Clear NVRAMSerial Port1 Address/ Serial Port2 Address XSuper IO Device ConfigurationXRemote Access Configuration Remote AccessTerminal Type XHardware Health ConfigurationRedirection After BIOS POST CPU Overheat AlarmThe item displays the absolute temperature as detected by the BIOS CPU TemperatureSystem Temperature Fan1 ~ Fan 5 Reading XACPI ConfigurationACPI Version Features Fan Speed Control ModesXTrusted Computing XIPMI ConfigurationExecute TPM Command TPM Enable/Disable StatusClear BMC System Event Log Set LAN ConfigurationSet PEF Configuration View Event Log XEvent Log ConfigurationBMC Watch Dog Timer Action BMC WatchDog TimeOut MinSecChange Supervisor Password 7-4 Security SettingsSupervisor Password User PasswordBoot Sector Virus Protection Change User PasswordXHard Disk Drives 7-5 Boot SettingsXBoot Device Priority Save Changes and Exit 7-6 Exit OptionsXRemovable Drives XCD/DVD DrivesDiscard Changes Load Optimal DefaultsLoad Fail-Safe Defaults Discard Changes and ExitRecoverable POST Error Beep Codes Appendix A POST Error Beep CodesB-1 Installing Windows on RAID Systems Appendix B Installing the Windows OSB-2 Installing Windows on Non-RAID Systems Chipset Appendix C SpecificationsBIOS ProcessorsOperating Environment WeightPower Supply System Input Requirements