Acnodes RMC 7132 Type, LBA/Large Mode, Block Multi-Sector Transfer, PIO Mode, 1U Rackmount System

Page 79
Type

RMC 7132

1U Rackmount System

activate the following submenu screen for detailed options of these items. Set the correct configura- tions accordingly. The items included in the submenu are:

Type

Select the type of device connected to the system. The options are Not Installed,

Auto, CD/DVD and ARMD.

LBA/Large Mode

LBA (Logical Block Addressing) is a method of addressing data on a disk drive. In the LBA mode, the maximum drive capacity is 137 GB. For drive capacities over 137 GB, your system must be equipped with a 48-bit LBA mode addressing. If not, contact your manufacturer or install an ATA/133 IDE controller card that supports 48-bit LBA mode. The options are Disabled and Auto.

Block (Multi-Sector Transfer)

Block Mode boosts the IDE drive performance by increasing the amount of data transferred. Only 512 bytes of data can be transferred per interrupt if Block Mode is not used. Block Mode allows transfers of up to 64 KB per interrupt. Select Disabled to allow data to be transferred from and to the device one sector at a time. Select Auto to allow data transfer from and to the device occur multiple sectors at a time if the device supports it. The options are Auto and Disabled.

PIO Mode

The IDE PIO (Programmable I/O) Mode programs timing cycles between the IDE drive and the programmable IDE controller. As the PIO mode increases, the cycle time decreases. The options are Auto, 0, 1, 2, 3, and 4.

Select Auto to allow the AMI BIOS to automatically detect the PIO mode. Use this value if the IDE disk drive support cannot be determined.

Select 0 to allow the AMI BIOS to use PIO mode 0. It has a data transfer rate of 3.3 MBs.

Select 1 to allow the AMI BIOS to use PIO mode 1. It has a data transfer rate of 5.2 MBs.

Select 2 to allow the AMI BIOS to use PIO mode 2. It has a data transfer rate of 8.3 MBs. Select 3 to allow the AMI BIOS to use PIO mode 3. It has a data transfer rate of 11.1 MBs.

Select 4 to allow the AMI BIOS to use PIO mode 4. It has a data transfer band- width of 32-Bits. Select Enabled to enable 32-Bit data transfer.

 

© Copyright 2009 Acnodes, Inc.

661 Brea Canyon Rd., Suite 3

All rights reserved. Product description and product specifications

Walnut, CA 91789

are subject to change without notice. For latest product information,

tel: 909.598.7388, fax: 909.598.0218

please visit Acnodes’ web site at www.acnodes.com.

Image 79
Contents RMC7132 1U Rackmount Computer comes with 1U Rackmount SystemAll rights reserved. Product description and product specifications User ManualManual Revision Release Date April 26 Manual Organization Chapter 2 Server InstallationChapter 4 System Safety PrefaceAppendix A POST Error Beep Codes Appendix B Installing the Windows OS Chapter 5 Advanced Motherboard SetupChapter 6 Advanced Chassis Setup Chapter 7 BIOS1-3 Server Chassis Features CHAPTER 2 INSTALLATIONCHAPTER 1 INTRODUCTION Table of Contents2-6 Checking the Drive Bay Setup CHAPTER 4 SYSTEM SAFETYCHAPTER 5 ADVANCED MOTHERBOARD SETUP CHAPTER 3 System Interface5-6 Installing Memory Modules 5-5 Installing the Processor and Heatsink5-7 Adding PCI Expansion Cards Serial Ports CHAPTER 7 BIOS CHAPTER 6 ADVANCED CHASSIS SETUPAppendix C System Specifications Appendix A POST Error Beep Codes Appendix B Installing the Windows OS1.1 Overview CHAPTER 1 INTRODUCTIONMemory 1-2 Motherboard FeaturesOther Features Processor661 Brea Canyon Rd., Suite Control Panel 1-3 Server Chassis FeaturesSystem Power SATA Subsystem2-1 Overview CHAPTER 2 INSTALLATIONChoosing a Setup Location 2-3 Preparing for SetupServer Precautions Rack PrecautionsMechanical Loading Rack Mounting ConsiderationsAmbient Operating Temperature Reduced AirflowIdentifying the Sections of the Rack Rails 2-4 Installing the System into a RackInstalling the Rack Rails Installing the Chassis RailsInstalling the Server into the Rack Installing the Server into a Telco Rack Checking the Components 2-5 Checking the Motherboard Setup661 Brea Canyon Rd., Suite Checking the Airflow 2-6 Checking the Drive Bay SetupProviding Power Checking the Drives3-1 Overview Reset ButtonPower CHAPTER 3 SYSTEM INTERFACEOverheat 3-4 Serial ATA Drive Carrier LEDs 4-1 Electrical Safety Precautions CHAPTER 4 SYSTEM SAFETY4-2 General Safety Precautions 4-3 ESD Precautions 4-4 Operating Precautions Precautions CHAPTER ADVANCED MOTHERBOARD SETUP5-1 Handling the Motherboard Installing to the Chassis 5-2 Serverboard InstallationUnpacking Connecting the Control Panel 5-3 Connecting CablesConnecting Data Cables Connecting Power Cables5-4 I/O Ports Installing an LGA1366 Processor 5-5 Installing the Processor and Heatsink6. Use your thumb to gently push the socket clip down to the clip lock Installing a Passive CPU Heatsink Removing the Heatsink To Remove 5-6 Installing Memory ModulesInstalling & Removing DIMMs To InstallMaximum Memory Possible Memory Support5-7 PCI Expansion Cards Installing a PCI Expansion Card5-8 Serverboard Details 661 Brea Canyon Rd., Suite Power Button 5-9 Connector DefinitionsMain ATX Power Supply Connector Processor Power ConnectorNIC2 LAN2 LED HDD LED/UID SwitchPower On LED Overheat/Fan Fail/UID LEDSerial Ports NMI ButtonFan Headers ATX PS/2 Keyboard and PS/2 Mouse PortsExternal Speaker/Internal Buzzer Onboard Power LEDChassis Intrusion Wake-On-LANLAN1/2 Ethernet Ports Power Supply SMBus HeaderUniversal Serial Bus USB SGPIO HeadersUnit Identifier Button Power Supply Fail LED HeaderAlarm Reset I-ButtonCMOS Clear 5-10 Jumper SettingsVGA Enable/Disable Explanation of JumpersWatch Dog Enable/Disable LAN1/2 Enable/DisableUSB Wake-Up LAN1/2 LEDs 5-11 Onboard IndicatorsBMC Enable/Disable SMBus to PCI Slots661 Brea Canyon Rd., Suite All rights reserved. Product description and product specifications1U Rackmount System Copyright 2005 Acnodes, Inc661 Brea Canyon Rd., Suite Driver/Tool Installation Display Screen 5-13 Installing SoftwareDoctor 661 Brea Canyon Rd., Suite 6-1 Static-Sensitive Devices CHAPTER 6 ADVANCED CHASSIS SETUPTools Required 6-2 Control Panel System Fan Failure 6-3 System FansReplacing System Cooling Fans Accessing the Drive Bays 6-4 Drive Bay Installation/RemovalSATA Drive Installation Mounting a SATA Drive in a Drive Carrier Installing/Removing SATA DrivesDVD-ROM Drive Installation SATA Power CablesInstalling a DVD-ROM Drive Power Supply Failure 6-5 Power SupplyReplacing the Power Supply 7-1 Introduction CHAPTER 7 BIOSStarting BIOS Setup Utility How To Change the Configuration DataStarting the Setup Utility 7-2 Main SetupSystem Memory System Time/System DateSystem Overview The following BIOS information will be displayed Bootup Num-Lock 7-3 Advanced Setup ConfigurationsXBIOS Features Quick Boot Quiet BootPS/2 Mouse Support Wait For F1 If ErrorPower Button Function Restore on AC Power LossXProcessor & Clock Options Ratio CMOS SettingHardware Prefetcher Available when supported by the CPU Adjacent Cache Line Prefetch Available when supported by the CPUIntel EIST Technology Intel Virtualization Technology Available when supported by the CPUSimultaneous Multi-Threading Available when supported by the CPU Intel TurboMode Tech Available if Intel EIST technology is EnabledTDC Limit Override Intel Turbo Boost Configuration Turbo Ratio Limit Program1 - Core Ratio Limit 2 ~ 3 - Core Ratio LimitC1 Auto Demotion C-State package limit settingXAdvanced Chipset Control C-STATE TechDemand Scrubbing QPI L0s and L1Memory Frequency Memory ModeAir Flow High Performance Event TimerInlet Temperature Temperature RiseUSB Functions Active State Power ManagementIntel VT-d Intel I/OATIDE Detect Timeout sec XIDE / Floppy ConfigurationSATA#1 Configuration Configure SATA#1 asPIO Mode TypeLBA/Large Mode Block Multi-Sector TransferS.M.A.R.T. For Hard disk drives DMA Mode32Bit Data Transfer Plug & Play OS XPCI/PnP ConfigurationPCI Latency Timer Clear NVRAMSerial Port1 Address/ Serial Port2 Address XSuper IO Device ConfigurationXRemote Access Configuration Remote AccessTerminal Type XHardware Health ConfigurationRedirection After BIOS POST CPU Overheat AlarmSystem Temperature CPU TemperatureThe item displays the absolute temperature as detected by the BIOS Fan1 ~ Fan 5 Reading XACPI ConfigurationACPI Version Features Fan Speed Control ModesXTrusted Computing XIPMI ConfigurationExecute TPM Command TPM Enable/Disable StatusSet PEF Configuration Set LAN ConfigurationClear BMC System Event Log View Event Log XEvent Log ConfigurationBMC Watch Dog Timer Action BMC WatchDog TimeOut MinSecChange Supervisor Password 7-4 Security SettingsSupervisor Password User PasswordBoot Sector Virus Protection Change User PasswordXBoot Device Priority 7-5 Boot SettingsXHard Disk Drives Save Changes and Exit 7-6 Exit OptionsXRemovable Drives XCD/DVD DrivesDiscard Changes Load Optimal DefaultsLoad Fail-Safe Defaults Discard Changes and ExitRecoverable POST Error Beep Codes Appendix A POST Error Beep CodesB-1 Installing Windows on RAID Systems Appendix B Installing the Windows OSB-2 Installing Windows on Non-RAID Systems Chipset Appendix C SpecificationsBIOS ProcessorsOperating Environment WeightPower Supply System Input Requirements