RMC 7132
1U Rackmount System
6-3 System Fans
Two
The fans can adjust their speed according to the heat level sensed in the system, which results in more efficient and quieter fan operation. Fan speed is controlled by a setting in BIOS (see Chapter 7).
System Fan Failure
If a fan fails, the ambient air temperature in the chassis will rise and activate the overheat LED on the control panel. You will need to power down the system to replace this fan with one of the same type (p/n
Replacing System Cooling Fans
1.Turn off the power to the system and remove the AC power cord.
2.Remove the chassis cover and unplug the fan cable from the serverboard
3.Unscrew the failed blower fan from the chassis and pull it completely out from the serverboard.
4.Replace the failed fan with an identical
5.After the new fan has been installed, plug the fan cable back into the same chassis fan header on the serverboard you removed it from.
6.Reconnect the AC power cord and power up the system.
7.Check that the fan is working properly and that the overheat LED on the control panel has turned
off.
8.Finish by replacing the top panel of the chassis.
| © Copyright 2009 Acnodes, Inc. |
661 Brea Canyon Rd., Suite 3 | All rights reserved. Product description and product specifications |
Walnut, CA 91789 | are subject to change without notice. For latest product information, |
tel: 909.598.7388, fax: 909.598.0218 | please visit Acnodes’ web site at www.acnodes.com. |