Barco R9840171, R9840170, R9840176 manual Configuration Setup

Page 21

Configuration Setup

Software download

The RS232/422 port is always enabled, this makes software upgrading always possible.

For software download follow next procedure:

1 Turn OFF the Remote Control with the main switch

2 Open the battery compartiment (see procedure page 14 )

3 Put switch C (image 2) located in the battery compartiment in the 'DOWNLOAD' position (right position) to enable downloading via the RS232 port

4 Connect the Remote with your PC using a standard serial cable 5 Turn the Remote on (main switch) and perfom the download

6 Put switch C back in the 'Normal' position and close the battery compartiment 7 Reset (OFF - ON with main switch) the remote control

image 2

C

21

Image 21
Contents R9840170 R9840171 R9840176 Rugged Remote Control for ELM/SLM ProjectorsPage Contents Safety Instructions Safety InstructionsInstallation Instructions Owners RecordSafety Warning On Safety100-240VAC 0.4A 47-63 Hz On installation Safety indication on the productOn servicing On cleaning On repackingDefinition Upgrade Kits Rugged Remote ControlAccessories General InformationContents Description SpecificationsSerial interface RS 232/422 Description & Specififcations ChargerExit Enter Description & Specififcations KeypadDescription & Specififcations Wireless Base Installation setup Installation SetupPower Connections Supplying the Wireless Base Installation Setup Power on switchNo Update No Communication ADDR=1 BAT=LOW Press Adjust to EnterInstallation Setup Charging the batteries Press ANY KEY to ExitInstallation Setup Changing the batteries Configuration Setup Configuration SetupRemote Mode Configuration Setup Lamp Read Mode ASLQ*1DVVDGDSWHU*1$ Configuration Setup RS232/422 CommunicationConfiguration Setup Configuration Setup RF Mode Download is performed through the RS232 communication port ADDR=1 No CommunicationInstallation Settings Identification menu Communication Menu COMM.PORT Auto Baudrate XLR Baudrate No Communication COM.PORT AutoNo Communication Setting UP Communication RF Options Press EnterPress Enter to browse Select Synchronize base No Update Base Synchronised Press Exit to ContinueHow to change the address Select Change address Installation settings menuNo Communication Change Address Operation Mode OPER. Mode Remote OPER. Mode Lamp Read BAT=ACT Press Adjust to EnterNo Communication Lamp Menu Setup Remote Mode Menu No Communication Operation Mode OPER. Mode RemoteSelect Operation Mode by pressing Enter Communication COM.PORT XLRAdditionnal Information Additionnal InformationMessages Dimensions Mechanical InformationMechanical Information Mechanical Information Barco NV / Projection Systems