Range: 0-127

Default: 8

S6

Wait Before Blind Dialing

The value of S6 specifies the amount of time that must elapse after the modem goes off-hook before the modem starts dialing the telephone number. The modem waits for at least 2 seconds before dialing even if the register is set for a value less than two.

Range: 2-255

Default: 2

S7

Wait for Carrier/Dial Tone

S7 specifies the length of time the modem waits to detect the remote modem car- rier after dialing. If the remote modem is not detected within that time, the modem hangs up and sends the “NO CARRIER” response.

Range: 1-255 seconds

Default: 60 seconds

S10

Lost Carrier Hang Up Delay

S10 is used to specify the length of time the modem waits before hanging up if the remote modem carrier signal is lost. When set to 255, the modem does not hang up when it loses the remote modem.

Range: 1-255 (1/10 of a second)

Default: 14 (1.4 seconds)

S11

DTMF Dialing Speed

S11 specifies the duration of DTMF (tone) dialing. This register is not used for pulse dialing.

Range: 50-255 ms.

Default: 70 ms.

S12

Guard Time

S12 is used to specify guard and detect times used for the escape sequence.

Range: 1-255 (1/50 of a second)

29

Image 29
Contents Page Table of Contents Do This First For Windows 3.1 InstallationWin95 Modems Properties Panel For Windows 95/98 InstallationPage Page Jumper Settings Installing The ModemJP2 IRQ interrupt request Options Hardware InstallationPage Configuring Windows Connecting Devices to the ModemConfiguring Windows 95 OEM SR2 Diskette or CD-ROM into the appropriate drive. Click Next Configuring Windows NTPage Full-Duplex Speakerphone Installing and Configuring Communications SoftwareData TIA/EIA-602 Fax TIA/EIA-578 for Class 1 Fax Voice Check Modem Properties TroubleshootingModem Diagnostics Page Common Problems No Dialtone Error Page +++ATCR Appendix a AT Command SetRegisters To display the value of an S-registerRepeat Last Command Enables echo to the computer default Disables echo to the computerOn-line Data Character Echo Command On-line character echo disabled. defaultThis command turns the speaker on or off Speaker is off Monitor Speaker ModeSpeaker is always on when modem is off-hook Return On-line to Data ModeResult Code Option Displays result codes as text defaultConnect result code reports DTE modem to computer speed Connect result code reports DTE speedQ0 Modem only supports asynchronous mode M0 Modem only supports asynchronous mode.defaultThis command selects DSR action S0 DSR always on default Data Set Ready DSR OptionSelect Stored Profile On Power-UP Modulation Selections Escape Character Page Default 50 1 second S25 Detect DTR Change FCC Part 68 Requirements Appendix B Communications RegulationsFCC Regulations Declaration of Conformity Requirements for End Users Canadian Department of Communications Cdoc