3Com EISA 10/100BASE-T manual Running the Group 3 Test, Mbps or 100 Mbps

Page 50

Starting the Diagnostic Program

5-5

To run the tests continuously, go to the Repetitions box on the Test Setup screen, and select Continuous (and deselect Halt on Error in the Errors box).

The Group 1 tests include:

Register Access Test

EEPROM Test

FIFO Loopback Test

Ethernet Core Loopback Test

Encoder/Decoder Loopback Test

Interrupt Test

For a description of each Group 1 test, access help by pressing [F1].

Running the Group 3 Test

The Group 3 test is called the Echo Exchange Test. It tests the adapter’s ability to transmit and receive data while on the network.

CAUTION: Running the Group 3 test while connected to an active network can cause intermittent failures. To avoid this, connect to an inactive network on which only the computer being tested and the echo server are operating.

To run the Group 3 test on the network, you need a second computer set up as an echo server. The echo server receives packets from the adapter being tested and echoes them back to the adapter.

The second computer must contain a 3Com adapter running at the same speed as the Fast EtherLink EISA adapter

(10 Mbps or 100 Mbps).

Image 50
Contents User Guide Fast Etherlink Parallel TaskingNetwork Adapter Adapters3Com Corporation 5400 Bayfront Plaza Santa Clara, California Lifetime Warranty France, Israel Contents Loading Network Drivers Cispr B Compliance Figures Tables Introduction How to Use This GuideAbout this Guide Conventions Print Autolink.logSingle-slot, 32-bit half-card Adapter FeaturesIntroduction Procedures described in this guide are shown in Figure Procedure OverviewInstalling the Hardware Hardware Installation OverviewInserting the Fast EtherLink Eisa Adapter Installing the Boot PromInspecting the Adapter Computer with PCI and Eisa Slots List of devices appears, arranged by type Confirming Adapter InstallationName of the installed 3Com adapter appears, as shown below Connecting to the Network Installing the Hardware Auto Select Media Type Configuring the Adapter Adapter Configuration OverviewUsing a NOS Other Than Windows Configuring the AdapterUsing Windows Software Option Settings Complete one of the following instructionsFull Duplex Media TypeNetwork Driver Optimization Multitasking environments, choosingChanging the Settings At the prompt, typeI N N U Press Tab to highlight OK. Press Enter Continue this procedure with any of the other optionsSecond dialog box appears Select Adapter Installed Adapters Loading Network DriversAccessing DOS Locating the Network DriversOne Eisa Adapter in a Client Describes how to access DOS from various operating systemsLoading NetWare ODI Drivers Loading Network Drivers Alternatively, at the prompt, type To view the full text of the license agreement, press F1Have only one 3Com Bus Master adapter installed Multiple Eisa Adapters in a Client To print the file, typeWhen the program has finished a Save the configuration Main menu appears Reboot the computer Finding the Adapter’s Slot NumberRepeat a for the second adapter One Eisa Adapter in a Server Multiple Eisa Adapters in a Server Loading NetWare ODI DriversFinding the Adapter’s Port Address for Multiple Adapters For NetWare 3.12, 4.0, or For the latest NLMs, contact NovellTo load other types of network drivers, follow these steps Loading Windows 95 DriversLoading Non-NetWare Drivers Windows NT, version Ndis DriversNdis Windows for Workgroups WindowsAdditional Drivers Transcend PC Link SmartAgent Driver AgentsDesktop Management Interface Performing Troubleshooting Diagnostic Tests Illustrates how the procedures in this chapter might be usedDiagnostic Tests Overview Before Running the TestsStarting the Diagnostic Program Types of TestsTo run the Group 1 tests, follow these steps Command Line AccessRunning the Group 1 Tests Press Enter to start the testsRunning the Group 3 Test Mbps or 100 MbpsSetting Up an Echo Server Enable the Group 3 test by selecting the Enable Group button Getting Help If a Test Fails Changing the Test Setup To change the test parameters, follow these stepsMiscellaneous Checks LEDs LEDPerforming Troubleshooting and Diagnostic Tests CSMA/CD local area network SpecificationsAdapter Card Specifications Local area networkCabling Requirements RJ-45 Connector Pin AssignmentsWhen properly connected to a 10BASE-T network, Maximum UTP cable distance is 100 meters at either speedAccess by Modem On-line Technical Services3Com Bulletin Board Service Technical SupportThreeComForum on CompuServe 3ComFacts Automated Fax ServiceWorld Wide Web Site To use ThreeComForum Log on to CompuServeDetails about recent configuration changes, if applicable Support from Your Network SupplierLocal numbers are available within the following countries Returning Products for Repair To obtain an RMA number, call or faxGlossary AUI cableBus BackboneBackplane DriverEthernet Echo serverEMM386 Transceiver Parallel TaskingServer Twisted-pairNumerics SymbolsIndex Diagnostic tests NLMs 4-10, 4-12 NETWARE\SERVER subdirectory 4-11 network Limited Warranty 3Com Corporation Bayfront Plaza Interference Handbook Cispr B Compliance