Adder Technology 2XPRO manual Logging access activity requires firmware v1.12 or above

Page 65

The pinout for a “daisy chain” RS232 cable for more than 2 units is shown below:

5.2 Logging access activity (requires firmware v1.12 or above)

By connecting the SmartView’s serial port to a computer, a time stamped log of the SmartView’s activity can be generated. This is useful for applications where it is necessary to keep track of which users have accessed which computers. A simple data logging program may be downloaded from the Adder Technology website (XPLOG.EXE). This enables the activity log to be saved to a file or printed to a printer. This logging program uses the Excel-compatible file XPRODATA.CSV (that may be downloaded from the SmartView – see section 4.2) to cross reference the port and user information to computer and user names in order to generate an informative activity log.

To make use of the activity logging features:

1.Download the program XPLOG.EXE from the support section of the Adder Technology website (www.adder.com).

2.Follow the instructions in section 4.2 to create the Excel compatible file XPRODATA.CSV that contains a list of user and computer names and port numbers.

3.Copy the XPRODATA.CSV file into the same directory as the XPLOG.EXE file.

4.Run the XPLOG file using the following command format:

XPLOG {activity_log_destination} {com_port}

SmartView XPro

Installation and Use

Page 64

Image 65
Contents SMARTView Xpro Warranty Safety informationSmartView XPro Installation and Use About this manualEuropean EMC directive 89/336/EEC Radio Frequency EnergyContents Appendices Using the SmartView XProWhat does KVM stand for? IntroductionAdder explains Key features and benefits SmartView XPro Installation and Use AdderLink Gold XR receiver package contents part code Algrx SmartView XPro package contentsAdderLink XR receiver package contents part code Alrx Product information Page Page Page Flexible configuration InstallationWhat you will need For the computer connections you will needFor the integrated AdderLink extender ports you will need For the local user port connections you will needImportant Warning Connecting your devicesMounting the SmartView SmartView XPro Installation and Use Structuring your SmartView XPro installation Configuring your PCsSmartView XPro Installation and Use SmartView XPro Installation and Use Page Page Page Maximising the video quality Re-enabling a disconnected PS/2 mouse Other useful installation informationSmartView XPro Installation and Use AdderLink requirements Connecting the AdderLink ExtenderConnecting an external AdderLink extender Configuration summary Configuring the SmartView XProDecide if you are going to use password security Create an Admin administration account passwordSet the required Setup Options and Global Preferences Enabling password securityCreate user accounts Add / edit names to identify your computersSetting an Admin password Creating and editing computer names Creating and editing user accountsTo create user accounts Follow a similar process to edit usersFollow a similar process to edit computer names To create computer namesSmartView XPro Installation and Use Page Possible cascade groups and their associated names Setting the Setup Options and Global PreferencesHotkeys SecurityLanguage Exclusive USE Keypad ControlsScreen Saver Mouse SwitchingAutomatic Logout To define the autoscan list Autoscan ModeAutoscan Time User TimeoutOSD Dwell Time 13 RS232 Mouse TypeRear panel special function switches Using the SmartView XProPower supply connections and indicators User display and key switchComputer display and key switch Selecting a computer using the front panel controls Activity indicatorsLogging on to the SmartView XPro Keyboard hotkeys ‘HOTKEYs’ and ‘1 then 1’ selects channel ‘HOTKEYs’ and ‘1 then 0’ selects channel‘HOTKEYs’ and ‘1 then 2’ selects channel ‘HOTKEYs’ and ‘1 then 3’ selects channelPress bavrelease vpress Release vpress vrelease vba Press ba2 release 2baSelecting computers using the mouse Press baM release Mba Selecting computers using the on-screen menuSmartView XPro Installation and Use Je or jf SmartView XPro Installation and Use Reminder banner BawReminder Banner Setting the User PreferencesOSD Colour Restore Standard Mouse Using the Functions menuRestore Intellimouse Reminder ColourQuerying the routing status Using the dual access ports 1Cascading SmartViews Press ba0release Press 1release Press 4release 4ba Resetting user port keyboards and miceWhat to do if you forget your Admin password Using the AdderLink extenderTo save the menu names and configuration settings To edit the menu names and configuration settings Baud 19200, bits 8, stopbits 1, paritynone Switching channels by sending RS232 dataSpecial features of the SmartView XPro SmartView XPro Installation and Use Logging access activity requires firmware v1.12 or above More information Xplog datalog.txtXplog Print Upgrading the SmartViews firmware Connect your computer to the SmartView XPro Prepare your computersPower on the SmartView with the Upgrade switch on Power off the SmartView XProRun the upgrade program SVXPRO.EXESvxpro 4X16V129.DAT Important Note 4X16V129.DATSvxpro Datfilename.DAT SmartView XPro Installation and Use Cable specification Appendix A. Cable and connector specificationsA1. Keyboard, monitor and mouse to SmartView XPro A2. AdderLink to SmartView XProA3. SmartView XPro to PCs 1 to Cable specificationsPart Code Description Recommended cablesAction Appendix B. Problem SolvingProblem SmartView XPro Installation and Use SmartView XPro Installation and Use S TA L L AT I O N & U S E