Canon RE-350 manual Mode Meaning, Adjusting the value of each control knob

Page 12

1.3.3 Procedure for Using the Control Knobs

 

Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Meaning

 

 

[OFF-LINE] Mode

Adjusting the value of each control knob.

 

 

 

 

The physical position of each control knob on the front panel is used to measure and

 

 

 

 

adjust it's respective value.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting the center target value for Auto-White Balance.

 

 

 

 

The physical position of the white balance control knob will be used as the center

 

 

 

 

value to measure and adjust the white balance.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[ON-LINE] Mode

Adjusting the value of each control knob.

 

 

 

 

The physical position of each control knob on the front panel will be disregarded

 

 

 

 

and the value of the “command data packet” from the PC will be used to measure

 

 

 

 

and adjust the control knob's respective value.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting the center target value for Auto-White Balance.

 

 

 

 

The control knob's physical position will be saved into the Auto-White Balance

 

 

 

 

position buffer when the RE-350shifts to [ON-LINE] Mode. If the PC gives the

 

 

 

 

proper command data to set the Auto-White Balance control knob's position, the

 

 

 

 

buffer data will be updated.

 

 

 

 

 

 

[NOTIFICATION] Mode

Adjusting the value of each control knob..

 

 

 

 

The physical position of each control knob on the front panel will be disregarded

 

 

 

 

and the value of the “command data packet” from the PC will be used to adjust the

 

 

 

 

control's respective value.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting the center target value for Auto-White Balance

 

 

 

 

The control knob's physical position will be saved into the Auto-White Balance

 

 

 

 

position buffer when the RE-350shifts to [ON-LINE] Mode. If the PC gives the

 

 

 

 

proper command data to set the Auto-White Balance control knob's position into

 

 

 

 

the buffer, the given data will be updated.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note:

When the mode of the RE-350shifts from [ON-LINE] Mode or [NOTIFICATION] Mode to [OFF-LINE] Mode, the center target value for Auto-White Balance will be changed from the value in the Auto-White Balance control knob position buffer to the physical position of the Auto-White Balance control knob automatically. The manual white balance data given from the PC will be disregarded.

12

Image 12
Contents RE-350 Control Interface Command Index Panel Diagrams Operations and FunctionsDescription of the Front and Rear Panel Functions Key FunctionButton Detail Button Control Knob Digital Switches Main power is turned onPower supply SCp180 Operational Procedures Overview Operations RE-350s Condition and LED StatusOperations RE-350will operate according to the given AvailableFront panel PC and the RS-232 LED will blink RS-232 LED remains onMode Meaning Adjusting the value of each control knobSetting the center target value for Auto-White Balance Function of RS-232 button LineRequest on LineLineRequest OFF Line Default Setting of Each Function After Power-On Auto-white balance was adjusted successfullyMeaning of Each LED Status StatusControl Protocol Packet Discrimination Code AssignmentID number ParameterData Packet Configuration Control Command Packet Format PC RE-350Response Data Packet Format PC RE-350 Event Data Packet Format PC RE-350Operational Flow Chart Flow Pattern 1 Command Communication Flow PatternCommand Response Flow Pattern 2 Event Packet Flow PatternFlow Pattern 3 Notification Mode Flow Pattern FP Data PacketResponse data Control Command and Packet Tables Camera Control Commands TableSystem Control Commands Table LEDSystem error response Mode error responseTime out error response Response Data Packet TableEvent Data Packet Table Event Description Byte Header ID #ParaL Request on lineAccepted DeniedFP Data Packet Table FP data description ByteParaH ParaL Description Command Data Packet Zoom CommandsWide Zoom Constant Speed $10 $ 0Tele Zoom Constant Speed Tele Zoom StepZoom Access To Position Zoom StopZoom Request Position Zoom Wide Constant Speed w/ AF † Zoom Tele Constant Speed w/ AF †Focus Commands OP AF Operate Auto Focus$10 $ 1 $ 0 Focus Near Constant SpeedFocus Near Step Focus Far Constant SpeedFunction Focus Far Step Focus StopWhite Balance Commands White Balance Manual Access ToOP AWB Operate Auto-White Balance $10 $ 2 $ 0Exposure Commands Exposure Manual Access To$10 $ 2A $ 0 Detail Commands Detail Manual Access ToPositive/Negative Commands Set Positive Mode †Set Negative Mode † $10 $ 3 $ 0Color/B&W Commands Set Color ModeSet B/W Mode $10 $ 4 $ 0System Control Commands Detailed System Control CommandsSelect Document Video $10 $ 5 $ 0Document Lights On † Document Lights Off †Backlight On † Backlight Off †LED Normal $10 $ 6 $ 0LED On LED Off $10 $ 6 a $ 0LED Blink $10 $ 6 B $ 0OFF-LINE Mode ON-LINE Mode$10 $ 7 $ 0 Notification Mode Maximum operation time msec 100 millisecond Command format Status of Group aVideo C/M $10 $ 8 $ 0Status of Group B InputFunction To get the status data of Group B from the RE-350 = onStatus of the Buttons FocusInput RS-232 Auto BacklightStatus of WB control knob Status of EXP control knobParameter of the C-response Packet MSH $00 fixed Status of Detail control knob Status of AWB resultFunction Gets the position data of the Detail control knob Name of the Equipment Version of ROMParameter of the C-response Packet Set to Special Mode $10 $F F $ 0Set to Service Mode $10 $F F $ F FControl Cable Pin Assignments RS-232C Control Cable Pin AssignmentRE-350 Control Cable Pin Assignments Pin Dsub RS-232C RE-350Page Timing Charts RTS/CTS Flow Control Timing ChartCommand Mark Duration period Min Max 300ms 200ms 10ms T4-T2RTS flow control timing chart Mark Duration period Min Max44ms 300ms 58ms 300ms 1000ms 200msRE-350 Software Developers Disk Installation Appendix a Disk InformationRE-350 Demo Application \APP RE-350 SDK File DefinitionsExecute an RE-350command RE-350 16bit Sample Code \16BITSDKInitialize communications with the RE-350 Close communications with the RE-350Execute an RE-350 command RE-350 32bit Sample Code \32BITSDK