Canon RE-350 manual Control Protocol, Packet Discrimination Code Assignment, ID number, Parameter

Page 15

1.6 Control Protocol

RS-232C Interface Connection

 

Transmission Mode

Full Duplex

Transfer Speed

9600 bps or 2400 bps

Start Bit

1 bit

Data Bit

8 bit

Parity

0 bit

Stop Bit

2 bit

Handshake

RTS/CTS flow control

Others

One response per Command

Note:RS-232Chand shake control signals originate from the PC side (DTE) in this document. In this docu- ment, hexadecimal data will be defined with “$” in front of a number or “h” in back of a number.

1.7 Packet Discrimination Code Assignment

Hexadecimal

Function

10h

“Command Data Packet”

A0h

“C-response Data Packet”

20h

“Event Data Packet”

B0h

“E-response Data Packet”

30Fh

“FP Data Packet”

Every data packet consists of 5 bytes of data.

 

If the RE-350receives another kind of data packet which will be described below, the RE-350will disregard the data packet and while the RE-350recognizes the data packet is incorrect, the RE-350will inactivate the CTS signal line to the PC.

ID number

Each RE-350can have an individual ID number, (0,1,2 or 3), which will be set by digital switches 3 and 4 on the rear panel. The RE-350will neglect the command data packet which has a different ID number. The PC can recognize which RE-350responds.

Parameter

Each data packet has this parameter. If the data packet does not need the parameter, the content should be set by $0000.

15

Image 15
Contents RE-350 Control Interface Command Index Operations and Functions Panel DiagramsDescription of the Front and Rear Panel Functions Key FunctionButton Detail Button Control Knob Digital Switches Main power is turned onPower supply SCp180 Operations RE-350s Condition and LED Status Operational Procedures OverviewOperations RS-232 LED remains on RE-350will operate according to the givenAvailable Front panel PC and the RS-232 LED will blinkMode Meaning Adjusting the value of each control knobSetting the center target value for Auto-White Balance Function of RS-232 button LineRequest on LineLineRequest OFF Line Status Default Setting of Each Function After Power-OnAuto-white balance was adjusted successfully Meaning of Each LED StatusParameter Control ProtocolPacket Discrimination Code Assignment ID numberEvent Data Packet Format PC RE-350 Data Packet ConfigurationControl Command Packet Format PC RE-350 Response Data Packet Format PC RE-350Response Flow Pattern 2 Event Packet Flow Pattern Operational Flow ChartFlow Pattern 1 Command Communication Flow Pattern CommandFlow Pattern 3 Notification Mode Flow Pattern FP Data PacketResponse data Camera Control Commands Table Control Command and Packet TablesLED System Control Commands TableResponse Data Packet Table System error responseMode error response Time out error responseRequest on line Event Data Packet TableEvent Description Byte Header ID # ParaLDenied AcceptedFP Data Packet Table FP data description ByteParaH ParaL $10 $ 0 Description Command Data PacketZoom Commands Wide Zoom Constant SpeedTele Zoom Step Tele Zoom Constant SpeedZoom Stop Zoom Access To PositionZoom Request Position Zoom Tele Constant Speed w/ AF † Zoom Wide Constant Speed w/ AF †Focus Near Constant Speed Focus CommandsOP AF Operate Auto Focus $10 $ 1 $ 0Focus Near Step Focus Far Constant SpeedFunction Focus Stop Focus Far Step$10 $ 2 $ 0 White Balance CommandsWhite Balance Manual Access To OP AWB Operate Auto-White BalanceExposure Commands Exposure Manual Access To$10 $ 2A $ 0 Detail Manual Access To Detail Commands$10 $ 3 $ 0 Positive/Negative CommandsSet Positive Mode † Set Negative Mode †$10 $ 4 $ 0 Color/B&W CommandsSet Color Mode Set B/W Mode$10 $ 5 $ 0 System Control CommandsDetailed System Control Commands Select Document VideoDocument Lights Off † Document Lights On †Backlight Off † Backlight On †$10 $ 6 $ 0 LED NormalLED On $10 $ 6 a $ 0 LED Off$10 $ 6 B $ 0 LED BlinkOFF-LINE Mode ON-LINE Mode$10 $ 7 $ 0 Notification Mode $10 $ 8 $ 0 Maximum operation time msec 100 millisecond Command formatStatus of Group a Video C/M= on Status of Group BInput Function To get the status data of Group B from the RE-350Backlight Status of the ButtonsFocus Input RS-232 AutoStatus of WB control knob Status of EXP control knobParameter of the C-response Packet MSH $00 fixed Status of Detail control knob Status of AWB resultFunction Gets the position data of the Detail control knob Name of the Equipment Version of ROMParameter of the C-response Packet $10 $F F $ 0 Set to Special Mode$10 $F F $ F F Set to Service ModeRS-232C Control Cable Pin Assignment Control Cable Pin AssignmentsRE-350 RE-350 Control Cable Pin Assignments Pin Dsub RS-232CPage Mark Duration period Min Max 300ms 200ms 10ms T4-T2 Timing ChartsRTS/CTS Flow Control Timing Chart Command58ms 300ms 1000ms 200ms RTS flow control timing chartMark Duration period Min Max 44ms 300msAppendix a Disk Information RE-350 Software Developers Disk InstallationRE-350 SDK File Definitions RE-350 Demo Application \APPClose communications with the RE-350 Execute an RE-350commandRE-350 16bit Sample Code \16BITSDK Initialize communications with the RE-350RE-350 32bit Sample Code \32BITSDK Execute an RE-350 command