Canon RE-350 manual Control Command and Packet Tables, Camera Control Commands Table

Page 19

2.0 Control Command and Packet Tables

2.1 Camera Control Commands Table

 

 

 

Maximum

1 byte

2 byte

3 byte

4 byte

5 byte

#

Name

Description

operation

Header

ID number

Command

Param(H)

Param(L)

time(ms)

 

 

 

 

 

 

 

 

 

Zoom

 

 

 

 

 

 

 

1

Cons-Spd wide Zoom

High speed Wide zoom

500

$10

$8*

$00

$01

$00

2

Step wide Zooming

Step feed wide zooming

2000

$10

$8*

$00

$03

$00

 

 

 

 

 

 

 

 

 

3

Cons-Spd Tele Zoom

High speed Tele zoom

500

$10

$8*

$01

$01

$00

4

Step Tele Zooming

Step feed tele zooming

2000

$10

$8*

$01

$03

$00

5

Stop Zooming

Stop zooming motor

500

$10

$8*

$02

$00

$00

6

Access-to-Zoom

Access to a Zoom Position

9000

$10

$8*

$03

$00

$**

7

Request Zoom

Request Zoom position

100

$10

$8*

$04

$00

$00

8

Wide Zoom w/ AF

High spd Wide zoom w/AF

500

$10

$8*

$05

$00

$00

9

Tele Zoom w/ AF

High spd Tele zoom w/AF

500

$10

$8*

$06

$00

$00

 

Focus

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

OP AF

Operate auto focus

20000

$10

$8*

$10

$00

$00

 

 

 

 

 

 

 

 

 

11

Cons-Spd focus near

High speed focus near

500

$10

$8*

$12

$01

$00

 

 

 

 

 

 

 

 

 

12

Step focus near

Step feed focus near

2000

$10

$8*

$12

$03

$00

 

 

 

 

 

 

 

 

 

13

Cons-Spd focus far

High speed focus far

500

$10

$8*

$13

$01

$00

 

 

 

 

 

 

 

 

 

14

Step focus far

Step feed focus far

2000

$10

$8*

$13

$03

$00

 

 

 

 

 

 

 

 

 

15

Stop focusing

Stop the auto focus

500

$10

$8*

$14

$00

$00

 

 

 

 

 

 

 

 

 

 

Color

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

OP AWB

Operate Auto White Bal.

7000

$10

$8*

$20

$00

$00

 

 

 

 

 

 

 

 

 

17

Access to WB

Access to a WB position

500

$10

$8*

$22

$00

$**

 

 

 

 

 

 

 

 

 

18

Access to EXP

Access to a EXP position

500

$10

$8*

$2A

$00

$**

 

 

 

 

 

 

 

 

 

19

Access to Detail

Access to a Detail position

500

$10

$8*

$30

$00

$**

 

 

 

 

 

 

 

 

 

20

Set Positive mode ††

Set positive image mode

500

$10

$8*

$38

$00

$00

21

Set Negative mode ††

Set negative image mode

500

$10

$8*

$38

$01

$00

 

 

 

 

 

 

 

 

 

22

Set Color mode

Set Color output mode

500

$10

$8*

$40

$00

$00

 

 

 

 

 

 

 

 

 

23

Set B/W mode

Set B/W output mode

500

$10

$8*

$40

$01

$00

 

 

 

 

 

 

 

 

 

The RE-350responds with a C-response data packet immediately after the reception of this command, but it is still working on the Zoom control and AF adjustment.

††The RE-350responds with a C-response data packet immediately after the reception of this command, but it is still working on the AWB adjustment.

19

Image 19
Contents RE-350 Control Interface Command Index Operations and Functions Panel DiagramsKey Function Description of the Front and Rear Panel FunctionsButton Detail Button Main power is turned on Control Knob Digital SwitchesPower supply SCp180 Operations RE-350s Condition and LED Status Operational Procedures OverviewOperations RS-232 LED remains on RE-350will operate according to the givenAvailable Front panel PC and the RS-232 LED will blinkAdjusting the value of each control knob Mode MeaningSetting the center target value for Auto-White Balance LineRequest on Line Function of RS-232 buttonLineRequest OFF Line Status Default Setting of Each Function After Power-OnAuto-white balance was adjusted successfully Meaning of Each LED StatusParameter Control ProtocolPacket Discrimination Code Assignment ID numberEvent Data Packet Format PC RE-350 Data Packet ConfigurationControl Command Packet Format PC RE-350 Response Data Packet Format PC RE-350Response Flow Pattern 2 Event Packet Flow Pattern Operational Flow ChartFlow Pattern 1 Command Communication Flow Pattern CommandFP Data Packet Flow Pattern 3 Notification Mode Flow PatternResponse data Camera Control Commands Table Control Command and Packet TablesLED System Control Commands TableResponse Data Packet Table System error responseMode error response Time out error responseRequest on line Event Data Packet TableEvent Description Byte Header ID # ParaLDenied AcceptedFP data description Byte FP Data Packet TableParaH ParaL $10 $ 0 Description Command Data PacketZoom Commands Wide Zoom Constant SpeedTele Zoom Step Tele Zoom Constant SpeedZoom Stop Zoom Access To PositionZoom Request Position Zoom Tele Constant Speed w/ AF † Zoom Wide Constant Speed w/ AF †Focus Near Constant Speed Focus CommandsOP AF Operate Auto Focus $10 $ 1 $ 0Focus Far Constant Speed Focus Near StepFunction Focus Stop Focus Far Step$10 $ 2 $ 0 White Balance CommandsWhite Balance Manual Access To OP AWB Operate Auto-White BalanceExposure Manual Access To Exposure Commands$10 $ 2A $ 0 Detail Manual Access To Detail Commands$10 $ 3 $ 0 Positive/Negative CommandsSet Positive Mode † Set Negative Mode †$10 $ 4 $ 0 Color/B&W CommandsSet Color Mode Set B/W Mode$10 $ 5 $ 0 System Control CommandsDetailed System Control Commands Select Document VideoDocument Lights Off † Document Lights On †Backlight Off † Backlight On †$10 $ 6 $ 0 LED NormalLED On $10 $ 6 a $ 0 LED Off$10 $ 6 B $ 0 LED BlinkON-LINE Mode OFF-LINE Mode$10 $ 7 $ 0 Notification Mode $10 $ 8 $ 0 Maximum operation time msec 100 millisecond Command formatStatus of Group a Video C/M= on Status of Group BInput Function To get the status data of Group B from the RE-350Backlight Status of the ButtonsFocus Input RS-232 AutoStatus of EXP control knob Status of WB control knobParameter of the C-response Packet MSH $00 fixed Status of AWB result Status of Detail control knobFunction Gets the position data of the Detail control knob Version of ROM Name of the EquipmentParameter of the C-response Packet $10 $F F $ 0 Set to Special Mode$10 $F F $ F F Set to Service ModeRS-232C Control Cable Pin Assignment Control Cable Pin AssignmentsRE-350 RE-350 Control Cable Pin Assignments Pin Dsub RS-232CPage Mark Duration period Min Max 300ms 200ms 10ms T4-T2 Timing ChartsRTS/CTS Flow Control Timing Chart Command58ms 300ms 1000ms 200ms RTS flow control timing chartMark Duration period Min Max 44ms 300msAppendix a Disk Information RE-350 Software Developers Disk InstallationRE-350 SDK File Definitions RE-350 Demo Application \APPClose communications with the RE-350 Execute an RE-350commandRE-350 16bit Sample Code \16BITSDK Initialize communications with the RE-350RE-350 32bit Sample Code \32BITSDK Execute an RE-350 command
Related manuals