Canon RE-350 manual Function of RS-232 button, LineRequest on Line, LineRequest OFF Line

Page 13

1.3.4 Procedure for Using the {RS-232} Button

Function of {RS-232} button

By pressing this button, toggles the RE-350's RS232C I/F from active to inactive for communication with the PC or another controller device.

Once the RE-350detects that the {RS-232} button was pressed, the RE-350will send an Event data packet to the PC through the RS232C I/F to tell the PC that the operator is trying to change the mode.

The Event data packet will differ according to the RE-350's current mode.

Current Mode

The Kind of Event-data-packet

 

 

OFF

LineRequest ON Line

 

 

ON

LineRequest OFF Line

Notification

Request OFF Line

 

 

Note:

1.The RE-350will shift its mode after the RE-350receives an <Accepted> E-response data from the PC.

The RE-350can not shift its mode to [NOTIFICATION] Mode directly. In order to set RE-350to [NOTIFICATION] Mode, the PC has to give the <Notification> command to the RE-350while in [ON LINE] Mode.

2.After the {RS-232} button is pressed and before the mode of the RE-350is determined, the RE-350will be in a mode transition. To tell this transition status to the operator, the RE-350's RS-232 LED will blink. While the RE-350is in this transition, every button, control knob or command from the PC, will be disregarded.

13

Image 13
Contents RE-350 Control Interface Command Index Operations and Functions Panel DiagramsKey Function Description of the Front and Rear Panel FunctionsButton Detail Button Main power is turned on Control Knob Digital SwitchesPower supply SCp180 Operations RE-350s Condition and LED Status Operational Procedures OverviewOperations Available RE-350will operate according to the givenFront panel PC and the RS-232 LED will blink RS-232 LED remains onAdjusting the value of each control knob Mode MeaningSetting the center target value for Auto-White Balance LineRequest on Line Function of RS-232 buttonLineRequest OFF Line Auto-white balance was adjusted successfully Default Setting of Each Function After Power-OnMeaning of Each LED Status StatusPacket Discrimination Code Assignment Control ProtocolID number ParameterControl Command Packet Format PC RE-350 Data Packet ConfigurationResponse Data Packet Format PC RE-350 Event Data Packet Format PC RE-350Flow Pattern 1 Command Communication Flow Pattern Operational Flow ChartCommand Response Flow Pattern 2 Event Packet Flow PatternFP Data Packet Flow Pattern 3 Notification Mode Flow PatternResponse data Camera Control Commands Table Control Command and Packet TablesLED System Control Commands TableMode error response System error responseTime out error response Response Data Packet TableEvent Description Byte Header ID # Event Data Packet TableParaL Request on lineDenied AcceptedFP data description Byte FP Data Packet TableParaH ParaL Zoom Commands Description Command Data PacketWide Zoom Constant Speed $10 $ 0Tele Zoom Step Tele Zoom Constant SpeedZoom Stop Zoom Access To PositionZoom Request Position Zoom Tele Constant Speed w/ AF † Zoom Wide Constant Speed w/ AF †OP AF Operate Auto Focus Focus Commands$10 $ 1 $ 0 Focus Near Constant SpeedFocus Far Constant Speed Focus Near StepFunction Focus Stop Focus Far StepWhite Balance Manual Access To White Balance CommandsOP AWB Operate Auto-White Balance $10 $ 2 $ 0Exposure Manual Access To Exposure Commands$10 $ 2A $ 0 Detail Manual Access To Detail CommandsSet Positive Mode † Positive/Negative CommandsSet Negative Mode † $10 $ 3 $ 0Set Color Mode Color/B&W CommandsSet B/W Mode $10 $ 4 $ 0Detailed System Control Commands System Control CommandsSelect Document Video $10 $ 5 $ 0Document Lights Off † Document Lights On †Backlight Off † Backlight On †$10 $ 6 $ 0 LED NormalLED On $10 $ 6 a $ 0 LED Off$10 $ 6 B $ 0 LED BlinkON-LINE Mode OFF-LINE Mode$10 $ 7 $ 0 Notification Mode Status of Group a Maximum operation time msec 100 millisecond Command formatVideo C/M $10 $ 8 $ 0Input Status of Group BFunction To get the status data of Group B from the RE-350 = onFocus Status of the ButtonsInput RS-232 Auto BacklightStatus of EXP control knob Status of WB control knobParameter of the C-response Packet MSH $00 fixed Status of AWB result Status of Detail control knobFunction Gets the position data of the Detail control knob Version of ROM Name of the EquipmentParameter of the C-response Packet $10 $F F $ 0 Set to Special Mode$10 $F F $ F F Set to Service ModeRS-232C Control Cable Pin Assignment Control Cable Pin AssignmentsRE-350 RE-350 Control Cable Pin Assignments Pin Dsub RS-232CPage RTS/CTS Flow Control Timing Chart Timing ChartsCommand Mark Duration period Min Max 300ms 200ms 10ms T4-T2Mark Duration period Min Max RTS flow control timing chart44ms 300ms 58ms 300ms 1000ms 200msAppendix a Disk Information RE-350 Software Developers Disk InstallationRE-350 SDK File Definitions RE-350 Demo Application \APPRE-350 16bit Sample Code \16BITSDK Execute an RE-350commandInitialize communications with the RE-350 Close communications with the RE-350RE-350 32bit Sample Code \32BITSDK Execute an RE-350 command