Canon RE-350 manual Response Data Packet Table, Response Description Byte, System error response

Page 21

2.3 C-response Data Packet Table

 

C-response Description

1 byte

2 byte

3 byte

4 byte

5 byte

 

 

 

 

Header

ID #

Response

Para(H)

Para(L)

 

 

 

 

 

 

 

 

 

 

 

 

Response without parameter

$A0

$8*

$00

$00

$00

 

 

 

 

 

 

 

 

 

 

 

 

Read Zoom position

$A0

$8*

$10

$00

$**

 

 

 

 

 

 

 

 

 

 

 

 

Status of Group A

$A0

$8*

$20

$**

$**

 

 

 

 

 

 

 

 

 

 

 

 

Status of Group B

$A0

$8*

$21

$**

$00

 

 

 

 

 

 

 

 

 

Normal

Response

Status of Button

$A0

$8*

$30

$**

$**

 

 

 

 

 

 

Status of WB control knob

$A0

$8*

$40

$00

$**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Status of EXP control knob

$A0

$8*

$41

$00

$**

 

 

 

 

 

 

 

 

 

 

 

 

Status of Detail control knob

$A0

$8*

$42

$00

$**

 

 

 

 

 

 

 

 

 

 

 

 

Status of AWB result

$A0

$8*

$43

$00

$**

 

 

 

 

 

 

 

 

 

 

 

 

Name of the Equipment

$A0

$8*

$48

$**

$**

 

 

 

 

 

 

 

 

 

 

 

 

Version of ROM

$A0

$8*

$49

$**

$**

 

 

 

 

 

 

 

 

 

 

Response

System Error

$A0

$8*

$F0

$00

$00

Error

 

 

 

 

 

 

Mode Error

$A0

$8*

$F0

$00

$01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Time out error

$A0

$8*

$F0

$00

$02

 

 

 

 

 

 

 

 

 

System error response

If the RE-350has a fatal error which it cannot recover from while performing a command from the PC, the RE-350will send this response and stop the current operation.

Mode error response

Depending on the mode, [ON-LINE] or [OFF-LINE], the RE-350 may not be able to execute some commands. In this case, the Mode error response will be sent to the PC.

For Example: If the RE-350is in the [OFF-LINE] Mode and the <Zoom Wide> command is issued, the RE-350will give a Mode error response because in this mode such a command cannot be executed.

Time out error response

When the RE-350is given the command <OP AF> or <OP AWB> from the PC and it tries to perform the command but cannot finish the operation successfully in an expected period, this error is given.

21

Image 21
Contents RE-350 Control Interface Command Index Operations and Functions Panel DiagramsDescription of the Front and Rear Panel Functions Key FunctionButton Detail Button Control Knob Digital Switches Main power is turned onPower supply SCp180 Operations RE-350s Condition and LED Status Operational Procedures OverviewOperations Available RE-350will operate according to the givenFront panel PC and the RS-232 LED will blink RS-232 LED remains onMode Meaning Adjusting the value of each control knobSetting the center target value for Auto-White Balance Function of RS-232 button LineRequest on LineLineRequest OFF Line Auto-white balance was adjusted successfully Default Setting of Each Function After Power-OnMeaning of Each LED Status StatusPacket Discrimination Code Assignment Control ProtocolID number ParameterControl Command Packet Format PC RE-350 Data Packet ConfigurationResponse Data Packet Format PC RE-350 Event Data Packet Format PC RE-350Flow Pattern 1 Command Communication Flow Pattern Operational Flow ChartCommand Response Flow Pattern 2 Event Packet Flow PatternFlow Pattern 3 Notification Mode Flow Pattern FP Data PacketResponse data Camera Control Commands Table Control Command and Packet TablesLED System Control Commands TableMode error response System error responseTime out error response Response Data Packet TableEvent Description Byte Header ID # Event Data Packet TableParaL Request on lineDenied AcceptedFP Data Packet Table FP data description ByteParaH ParaL Zoom Commands Description Command Data PacketWide Zoom Constant Speed $10 $ 0Tele Zoom Step Tele Zoom Constant SpeedZoom Stop Zoom Access To PositionZoom Request Position Zoom Tele Constant Speed w/ AF † Zoom Wide Constant Speed w/ AF †OP AF Operate Auto Focus Focus Commands$10 $ 1 $ 0 Focus Near Constant SpeedFocus Near Step Focus Far Constant SpeedFunction Focus Stop Focus Far StepWhite Balance Manual Access To White Balance CommandsOP AWB Operate Auto-White Balance $10 $ 2 $ 0Exposure Commands Exposure Manual Access To$10 $ 2A $ 0 Detail Manual Access To Detail CommandsSet Positive Mode † Positive/Negative CommandsSet Negative Mode † $10 $ 3 $ 0Set Color Mode Color/B&W CommandsSet B/W Mode $10 $ 4 $ 0Detailed System Control Commands System Control CommandsSelect Document Video $10 $ 5 $ 0Document Lights Off † Document Lights On †Backlight Off † Backlight On †$10 $ 6 $ 0 LED NormalLED On $10 $ 6 a $ 0 LED Off$10 $ 6 B $ 0 LED BlinkOFF-LINE Mode ON-LINE Mode$10 $ 7 $ 0 Notification Mode Status of Group a Maximum operation time msec 100 millisecond Command formatVideo C/M $10 $ 8 $ 0Input Status of Group BFunction To get the status data of Group B from the RE-350 = onFocus Status of the ButtonsInput RS-232 Auto BacklightStatus of WB control knob Status of EXP control knobParameter of the C-response Packet MSH $00 fixed Status of Detail control knob Status of AWB resultFunction Gets the position data of the Detail control knob Name of the Equipment Version of ROMParameter of the C-response Packet $10 $F F $ 0 Set to Special Mode$10 $F F $ F F Set to Service ModeRS-232C Control Cable Pin Assignment Control Cable Pin AssignmentsRE-350 RE-350 Control Cable Pin Assignments Pin Dsub RS-232CPage RTS/CTS Flow Control Timing Chart Timing ChartsCommand Mark Duration period Min Max 300ms 200ms 10ms T4-T2Mark Duration period Min Max RTS flow control timing chart44ms 300ms 58ms 300ms 1000ms 200msAppendix a Disk Information RE-350 Software Developers Disk InstallationRE-350 SDK File Definitions RE-350 Demo Application \APPRE-350 16bit Sample Code \16BITSDK Execute an RE-350commandInitialize communications with the RE-350 Close communications with the RE-350RE-350 32bit Sample Code \32BITSDK Execute an RE-350 command