^JE - Disable Diagnostics

This command disables Hex Dump mode.

~JP - Pause & Cancel

The PPI ONLINE light is illuminated when the printer is online.

^JU - Configuration Update

This command controls whether the printer reprints a label after a fault condition clears.

^JU op, num

op = Configuration update operation to perform. F: Load factory configuration

R:Load saved configuration number num

S:Save current configuration as power-up configuration number num

num = Configuration number to load, used only when op = R or S

^JV - Configuration Update

This command saves/loads the configuration ^JVa[,m]

a = F: Load factory emulation

S:Save configuration and as power-up configuration

R:Load saved configuration

m = 1 ... 8 (config number)

^JZ - Reprint After Error

The current setting is reflected in the corresponding front panel value. The conditions which generate a fault are determined by, and may be unique to, PSA.

~Lx - Base Emulation Support

PPI supports text printing using the LP+ emulation.

In addition to the three front panel LP+ Text Mode selections, there are three PPI commands which allow you to select the LP+ Text Mode through the data stream:

~L0 - LP+ Text Mode = Absorb (ZPL compatibility) ~L1 - LP+ Text Mode = Auto Pass-thru

~L2 - LP+ Text Mode = ZGL Quiet

With LP+ Text Mode set to “Absorb,” all non-PPI data is absorbed including any system-generated line terminators.