Zebra Technologies SL5000r/T5000r ~PP / PP Programmable Pause, ~PR / PP Print Rate, RS Rfid Setup

Models: SL5000r/T5000r

1 50
Download 50 pages 1.71 Kb
Page 35
Image 35

~PP / ^PP - Programmable Pause

The ~PP command takes the printer offline as soon as the current label being printed is completed. The exact moment at which this occurs in the label stream may not match exactly. The ^PP command takes the printer offline after the label definition in which the command appears is finished printing.

^PQ - Print Quantity

The ^PQ command controls printing operations such as the number of labels to print, labels printed before the printer pauses, and replications of each serial number.

~PR / ^PP - Print Rate

This command sets the print speed of the printer in inches per second. The exact set of available speed settings provided by the PPI is printer dependent and may not match those available through ZPL.

^RB - Define EPC Data Structure

This command defines the structure of EPC data, which can be read from or written to an RFID tag.

^RF - Read or Write RFID Format

This command allows you to read or write to an RFID tag. For PTX, the starting block number is one, since we only have one block of tag data. Zebra provides additional blocks but they are not being used.

^RM - Enable RFID Motion

This command enables or disables RFID motion. When disabled, Zebra does not move the label. PTX moves the label if there is data to print on the label. When enabled, both Zebra and PTX moves the label.

^RR - Specify RFID Retries for Read/Write

This command changes the number of times that the printer attempts to read or write to a tag. By default, Zebra attempts six retries. PTX attemps two retries. The command value ranges from 0 to 10 for Zebra and 1 to 9 for PTX.

NOTE: However, zero is not an available option for the SL5000r/T5000r printer.

^RS - RFID Setup

This command sets up parameters including tag type, read/write position of the transponder, and error handling. Currently, only the read/write position of the transponder and label retry are supported by PTX.

^RT - Read RFID Tag

This command tells the printer to read the current RFID tag data. For PTX, the starting block number is one, since we only have one block of tag data. Zebra provides additional blocks but they are not being used.