Chapter 1 PPI/ZGL SETUP Menu

Command Prefix

This item allows you to select the prefix for the control instructions command.

The range is 1-255, and the default is 126.

Label Prefix

This item allows you to select the prefix for the format instructions command.

The range is 1-255, and the default is 94.

Delimiter

This item allows you to select the delimiter used to separate the parameter of a command.

The range is 1-255, and the default is 44.

LP+ Text Mode

PPI supports text printing using the LP+ emulation.

Absorb (default). Use this setting for ZPL compatibility. This setting absorbs non-PPI data.

Auto Pass-thru. Use this setting for text printing. Non-PPI data is passed to the LP+ emulation.

ZGL Quiet. All data and PPI commands are passed to the LP+ emulation.

Preparser Command

The incoming data will be checked for the string “HS” or “JA” prior to entering the ZGL emulation parser based on the HS Command or the JA Command. Once the string is detected, the command will take effect immediately.

The default is HS Command.

Preparser Port

Disable (default). Disables the Preparser Command feature.

Parallel. Select Parallel if the data is coming to the printer through the parallel port.

Serial. Select Serial if the data is coming to the printer through the serial port.

12

Page 12
Image 12
Zebra Technologies SL5000r/T5000r manual Command Prefix, Label Prefix, Delimiter, LP+ Text Mode, Preparser Command