Status of WB control knob
•Function:
Gets the position data of the White Balance Manual control knob.
•Timing of the
•The parameter of the “C-response Packet”:
MSH: $00 fixed | LSH: $00 ~ $FF |
•The maximum operation time (msec): 100 millisecond
•Command format:
Header | ID number | Command | Parameter MSH Parameter LSH |
$10
$ 8 *
$ 82
$ 0 0
$ 0 0
Status of EXP control knob
•Function:
Gets the position data of the EXP control knob. (EXP = exposure)
•Timing of the
•The parameter of the
MSH: $00 fixed | LSH: $00 ~ $FF |
•The maximum operation time (msec): 100 millisecond
•Command format:
Header | ID number | Command | Parameter MSH Parameter LSH |
$10
$ 8 *
$ 82
$ 0 1
$ 0 0