2.2 System Control Commands Table

 

 

 

Maximum

1 byte

2 byte

3 byte

4 byte

5 byte

#

Name

Description

operation

Header

ID number

Command

Param(H)

Param(L)

time(ms)

 

 

 

 

 

 

 

 

 

Select Input Signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Select Document Video

Output Camera signal

500

$10

$8*

$50

$00

$00

 

 

 

 

 

 

 

 

 

2

Select External video

Output External signal

500

$10

$8*

$50

$01

$00

 

 

 

 

 

 

 

 

 

 

Light on/off Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Lights On ††

Turn Light On

500

$10

$8*

$58

$00

$00

4

Lights Off ††

Turn Light Off

500

$10

$8*

$58

$01

$00

5

Backlight On ††

Turn Backlight On

500

$10

$8*

$59

$00

$00

6

Backlight Off ††

Turn Backlight Off

500

$10

$8*

$59

$01

$00

 

LED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

LED Normal

Set LED Condition Normal

500

$10

$8*

$68

$**

$00

 

 

 

 

 

 

 

 

 

8

LED On

Turn LED On

500

$10

$8*

$69

$**

$00

 

 

 

 

 

 

 

 

 

9

LED Off

Turn LED Off

500

$10

$8*

$6A

$**

$00

 

 

 

 

 

 

 

 

 

10

LED Blink

Blink LED

500

$10

$8*

$6B

$**

$00

 

 

 

 

 

 

 

 

 

 

Communication Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

OFF Line

Set to [OFF LINE] Mode

500

$10

$8*

$70

$00

$00

 

 

 

 

 

 

 

 

 

12

ON Line

Set to [ON LINE] Mode

500

$10

$8*

$70

$01

$00

 

 

 

 

 

 

 

 

 

13

Notification

Set to [Notification] Mode

500

$10

$8*

$70

$02

$00

 

 

 

 

 

 

 

 

 

 

Status Request

 

 

 

 

 

 

 

14

Status of Group A

Request Status Group A

100

$10

$8*

$80

$00

$00

 

 

 

 

 

 

 

 

 

15

Status of Group B

Request Status Group B

100

$10

$8*

$80

$01

$00

 

 

 

 

 

 

 

 

 

16

Status of Button

Request Button condition

100

$10

$8*

$81

$00

$00

 

 

 

 

 

 

 

 

 

17

Status of WB Control

Request WB vol. position

100

$10

$8*

$82

$00

$00

 

 

 

 

 

 

 

 

 

18

Status of EXP Control

Request EXP vol. position

100

$10

$8*

$82

$01

$00

 

 

 

 

 

 

 

 

 

19

Status of Detail Vol.

Request Detail vol. position

100

$10

$8*

$82

$02

$00

 

 

 

 

 

 

 

 

 

20

Status of AWB Result

Request AWB result data

100

$10

$8*

$83

$00

$00

 

 

 

 

 

 

 

 

 

21

Name of Equipment

Request Name of equip.

100

$10

$8*

$88

$00

$00

 

 

 

 

 

 

 

 

 

22

Version of ROM

Request ROM version

100

$10

$8*

$88

$01

$00

 

 

 

 

 

 

 

 

 

 

Set to Special Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23

Set to Temporary Mode

Set to temp. mode

100

$10

$8*

$F0

$00

$00

 

 

 

 

 

 

 

 

 

24

Set to Service Mode

Set to service mode

100

$10

$8*

$F1

$FF

$FF

 

 

 

 

 

 

 

 

 

25

Set to Data Read Out

Set to data read mode

100

$10

$8*

$F1

$FF

$00

 

 

 

 

 

 

 

 

 

††The RE-350responds with a C-response data packet immediately after the reception of this command, but it is still working on the AWB adjustment.

20

Image 20
Contents RE-350 Control Interface Command Index Panel Diagrams Operations and FunctionsButton Description of the Front and Rear Panel FunctionsKey Function Detail Button Power supply Control Knob Digital SwitchesMain power is turned on SCp180 Operational Procedures Overview Operations RE-350s Condition and LED StatusOperations RE-350will operate according to the given AvailableFront panel PC and the RS-232 LED will blink RS-232 LED remains onSetting the center target value for Auto-White Balance Mode MeaningAdjusting the value of each control knob LineRequest OFF Line Function of RS-232 buttonLineRequest on Line Default Setting of Each Function After Power-On Auto-white balance was adjusted successfullyMeaning of Each LED Status StatusControl Protocol Packet Discrimination Code AssignmentID number ParameterData Packet Configuration Control Command Packet Format PC RE-350Response Data Packet Format PC RE-350 Event Data Packet Format PC RE-350Operational Flow Chart Flow Pattern 1 Command Communication Flow PatternCommand Response Flow Pattern 2 Event Packet Flow PatternResponse data Flow Pattern 3 Notification Mode Flow PatternFP Data Packet Control Command and Packet Tables Camera Control Commands TableSystem Control Commands Table LEDSystem error response Mode error responseTime out error response Response Data Packet TableEvent Data Packet Table Event Description Byte Header ID #ParaL Request on lineAccepted DeniedParaH ParaL FP Data Packet TableFP data description Byte Description Command Data Packet Zoom CommandsWide Zoom Constant Speed $10 $ 0Tele Zoom Constant Speed Tele Zoom StepZoom Access To Position Zoom StopZoom Request Position Zoom Wide Constant Speed w/ AF † Zoom Tele Constant Speed w/ AF †Focus Commands OP AF Operate Auto Focus$10 $ 1 $ 0 Focus Near Constant SpeedFunction Focus Near StepFocus Far Constant Speed Focus Far Step Focus StopWhite Balance Commands White Balance Manual Access ToOP AWB Operate Auto-White Balance $10 $ 2 $ 0$10 $ 2A $ 0 Exposure CommandsExposure Manual Access To Detail Commands Detail Manual Access ToPositive/Negative Commands Set Positive Mode †Set Negative Mode † $10 $ 3 $ 0Color/B&W Commands Set Color ModeSet B/W Mode $10 $ 4 $ 0System Control Commands Detailed System Control CommandsSelect Document Video $10 $ 5 $ 0Document Lights On † Document Lights Off †Backlight On † Backlight Off †LED Normal $10 $ 6 $ 0LED On LED Off $10 $ 6 a $ 0LED Blink $10 $ 6 B $ 0$10 $ 7 $ 0 OFF-LINE ModeON-LINE Mode Notification Mode Maximum operation time msec 100 millisecond Command format Status of Group aVideo C/M $10 $ 8 $ 0Status of Group B InputFunction To get the status data of Group B from the RE-350 = onStatus of the Buttons FocusInput RS-232 Auto BacklightParameter of the C-response Packet MSH $00 fixed Status of WB control knobStatus of EXP control knob Function Gets the position data of the Detail control knob Status of Detail control knobStatus of AWB result Parameter of the C-response Packet Name of the EquipmentVersion of ROM Set to Special Mode $10 $F F $ 0Set to Service Mode $10 $F F $ F FControl Cable Pin Assignments RS-232C Control Cable Pin AssignmentRE-350 Control Cable Pin Assignments Pin Dsub RS-232C RE-350Page Timing Charts RTS/CTS Flow Control Timing ChartCommand Mark Duration period Min Max 300ms 200ms 10ms T4-T2RTS flow control timing chart Mark Duration period Min Max44ms 300ms 58ms 300ms 1000ms 200msRE-350 Software Developers Disk Installation Appendix a Disk InformationRE-350 Demo Application \APP RE-350 SDK File DefinitionsExecute an RE-350command RE-350 16bit Sample Code \16BITSDKInitialize communications with the RE-350 Close communications with the RE-350Execute an RE-350 command RE-350 32bit Sample Code \32BITSDK