Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.Changes or modifications not expressly approved by Emerson could void the user's authority to operate the equipment. Board products are tested in a representative system to show compliance with the above mentioned requirements. A proper installation in a compliant system will maintain the required performance.Use only shielded cables when connecting peripherals to assure that appropriate radio frequency emissions compliance is maintained.

Operation

Damage of the RTM

High humidity and condensation on the RTM surface causes short circuits.

Do not operate the RTM outside the specified environmental limits. Make sure the RTM is completely dry and there is no moisture on any surface before applying power.

Do not operate the RTM below -5°C.

Installation

Damage of the RTM and Additional Devices and Modules

Incorrect installation or removal of additional devices or modules may damage the RTM or the additional devices or modules.

Before installing or removing additional devices or modules, read the respective documentation.

Damage of Circuits

Electrostatic discharge and incorrect installation and removal of the RTM can damage circuits or shorten their life.

Before touching the RTM or electronic components, make sure that your are working in an ESD-safe environment.

Damage of the RTM

Incorrect installation of the RTM can cause damage of the RTM.

Only use handles when installing/removing the RTM to avoid damage/deformation to the face plate and/or PCB.

14

RTM-ATCA-F120-OPT Installation and Use (6806800G29C)

Image 14
Contents RTM-ATCA-F120-OPT Contact Address Contents Contents RTM-ATCA-F120-OPT Installation and Use 6806800G29C List of TablesList of Tables List of Figures List of Figures Abbreviations Overview of ContentsAbout this Manual Notation Description ConventionsAbout this Manual BoldSummary of Changes Part Number Publication Date DescriptionAbout this Manual Safety Notes Electrical InterferenceOperation InstallationSafety Notes SFP/SFP+ Modules Environment Sicherheitshinweise EMV SicherheitshinweiseBeschädigung von Schaltkreisen Umweltschutz VerletzungsgefahrFeatures IntroductionIntroduction Standard Compliances Standard DescriptionOrdering Information Feature ValueMechanical Data Unpacking and Inspecting the RTM Hardware Preparation and InstallationOverview Environmental Requirements Environmental and Power RequirementsHardware Preparation and Installation Power Requirements Requirement Operating Non-OperatingInstalling and Removing the RTM Installing the RTMHardware Preparation and Installation Hardware Preparation and Installation Installation Procedure without Installed Front Blade Close the handles of the front blade Removal Procedure Removing the RTMHardware Preparation and Installation Installing and Removing SFP/ SFP+ Modules Hardware Preparation and Installation Installing an SFP/SFP+ Module ProcedureConnect the network cable to the SFP/SFP+ module Removing an SFP/SFP+ Module Remove any connected cable from the SFP moduleHardware Preparation and Installation Controls, LEDs and Connectors LEDs and Interface Connectors Controls, LEDs and ConnectorsLEDs Interface ConnectorsDuring RTM installation During RTM removalFabric Channel Uplinks Location of Ethernet Fabric Channel Uplink Interfaces Face Plate Label Ethernet TypeBase Channel Interface Connectors 2.1.2 1 GBit Fabric Interface UplinksLocation of Base Interface Uplink Interface Connectors 2.2.1 10 GBit Base Interface Uplinks 2.3 SFP/SFP+ Module Hot Swap Controls, LEDs and Connectors Telecom Clocking Connectors Location of Clock Extension ConnectorsSerial Interface Connector Location of Serial Interface Connectors Pin Signal Functional Description Block Diagram Functional DescriptionMezzanine Management Controller Sensor Name Sensor Type Sensor NumberRTM-F120-OPT MMC Functional Description Location of Ipmi Temperature Sensors Functional Description RTM-ATCA-F120-OPT Installation and Use 6806800G29C Document Title and Source Publication Number Emerson Network Power Embedded Computing DocumentsARelated Documentation Related Documentation Index Index Page HOW to Reach Literature and Technical Support Embedded Computing