Hardware Preparation and Installation
Table 2-1 Environmental Requirements
Requirement | Operating |
|
|
|
|
Temperature | 0ºC to +40ºC (normal operation) according | |
| to NEBS Standard |
|
| 0ºC to +55ºC (exceptional operation) |
|
| according to NEBS Standard |
|
|
|
|
Temp. Change | +/- 0.25ºC/min according to NEBS | +/- 0.25ºC/min |
| Standard |
|
|
|
|
Rel. Humidity | 5% to 95% | 5% to 95% |
| according to | |
| requirements | environmental requirements |
|
|
|
Vibration | 0.1g from 5 to 100 Hz and back to 5 Hz at | |
| a rate of 0.1 octave/minute | |
|
| |
|
| Random |
|
| Random |
Shock | Blade level packaging | |
|
| |
Free Fall |
| 1,200 mm/all edges and corners |
|
| 1.0m (Packaged) per ETSI 300 |
|
| |
|
| 100mm (unpackaged) per |
|
| CORE |
|
|
|
2.3.2Power Requirements
The RTM has a typical power dissipation of 22W, and a maximum power dissipation of 30W.
| 27 |