Emerson RTM-ATCA-F120-OPT manual Face Plate Label, Ethernet Type

Page 46

Controls, LEDs and Connectors

3.2.2.1.110 GBit Fabric Interface Channel Uplinks

The four cages for the 10 GBit uplinks can be equipped with standard optical SFP+ connectors and support Ethernet connections in compliance with the IEEEE 802.3ak standard. Alternatively, you may populate the SFP+ connectors with SFP connectors for copper and optical Ethernet connections. In this case, only 1 GBit connections are supported.

During the qualification testing of the RTM, the following SFP+ models were used:

z 10Gb/s 850nm Multimode Datacom SFP+ Transceiver (FTLX8571D3BCL). Orderable via Emerson P/N: 5806802A01

z RoHS-6 Compliant 10Gb/s 10km Single Mode Datacom SFP+ Transceiver (FTLX1471D3BCL). Orderable via Emerson P/N: 5806803A01

These modules passed all tests sucessfully without incidents. They are also listed in the Emerson Network Power sales configurator. When using SFP+ modules, we recommend to use these models.

The SFP/SFP+ modules can be installed/removed both while the RTM is powered and non- powered. The presence and also the type of SFP/SFP+ modules is automatically detected.

When using 1 GBit copper SFP modules, the speed is determined through auto-negotiation per the 802.11 Ethernet specification. Optical modules do not support auto-negotiation. The SFP cable should be appropriately matched to the SFP module type per the manufacturer’s recommendations.

The following table shows which switch MIB OID each cage corresponds to.

Table 3-2 Fabric Channel 10 GBit Uplink Connectors - Port - MIB OID Assignment

Face Plate Label

MIB OID

Ethernet Type

 

 

 

FIX XG1

<shelf>.<slot>.2.17

10 GBit

 

 

 

FIX XG2

<shelf>.<slot>.2.16

10 GBit

 

 

 

FIX XG3

<shelf>.<slot>.2.19

10 GBit

 

 

 

FIX XG4

<shelf>.<slot>.2.18

10 GBit

 

 

 

46

RTM-ATCA-F120-OPT Installation and Use (6806800G29C)

Image 46
Contents RTM-ATCA-F120-OPT Contact Address Contents Contents RTM-ATCA-F120-OPT Installation and Use 6806800G29C List of TablesList of Tables List of Figures List of Figures About this Manual Overview of ContentsAbbreviations Notation Description ConventionsAbout this Manual BoldSummary of Changes Part Number Publication Date DescriptionAbout this Manual Safety Notes Electrical InterferenceSafety Notes InstallationOperation SFP/SFP+ Modules Environment Sicherheitshinweise EMV SicherheitshinweiseBeschädigung von Schaltkreisen Umweltschutz VerletzungsgefahrFeatures IntroductionIntroduction Standard Compliances Standard DescriptionMechanical Data Feature ValueOrdering Information Overview Hardware Preparation and InstallationUnpacking and Inspecting the RTM Hardware Preparation and Installation Environmental and Power RequirementsEnvironmental Requirements Power Requirements Requirement Operating Non-OperatingInstalling and Removing the RTM Installing the RTMHardware Preparation and Installation Hardware Preparation and Installation Installation Procedure without Installed Front Blade Close the handles of the front blade Removal Procedure Removing the RTMHardware Preparation and Installation Installing and Removing SFP/ SFP+ Modules Hardware Preparation and Installation Installing an SFP/SFP+ Module ProcedureConnect the network cable to the SFP/SFP+ module Removing an SFP/SFP+ Module Remove any connected cable from the SFP moduleHardware Preparation and Installation Controls, LEDs and Connectors LEDs and Interface Connectors Controls, LEDs and ConnectorsLEDs Interface ConnectorsDuring RTM installation During RTM removalFabric Channel Uplinks Location of Ethernet Fabric Channel Uplink Interfaces Face Plate Label Ethernet TypeBase Channel Interface Connectors 2.1.2 1 GBit Fabric Interface UplinksLocation of Base Interface Uplink Interface Connectors 2.2.1 10 GBit Base Interface Uplinks 2.3 SFP/SFP+ Module Hot Swap Controls, LEDs and Connectors Telecom Clocking Connectors Location of Clock Extension ConnectorsSerial Interface Connector Location of Serial Interface Connectors Pin Signal Functional Description Block Diagram Functional DescriptionMezzanine Management Controller Sensor Name Sensor Type Sensor NumberRTM-F120-OPT MMC Functional Description Location of Ipmi Temperature Sensors Functional Description RTM-ATCA-F120-OPT Installation and Use 6806800G29C ARelated Documentation Emerson Network Power Embedded Computing DocumentsDocument Title and Source Publication Number Related Documentation Index Index Page HOW to Reach Literature and Technical Support Embedded Computing