49. Audio Select Request
Function
The external control equipment inquires the current combinations of audio and video inputs for the plasma monitor.
Transmission Data
1FH 80H 60H 6FH 00H CKS
ACK
The plasma monitor returns the following ACK:
7FH 60H 80H 6FH 03H DATA00 DATA01 DATA02 CKS
DATA00: | AUDIO 1 |
|
| 01H – 0CH: VISUAL INPUT DATA | |
DATA01: | AUDIO 2 |
|
| 01H – 0CH: VISUAL INPUT DATA | |
DATA02: | AUDIO 3 |
|
| 01H – 0CH: VISUAL INPUT DATA | |
| VISUAL INPUT DATA | |
| 01H: | Video 1 |
| 02H: | Video 2 |
| 03H: | Video 3 |
| 05H: | HD (HD1 or DTV or DTV 1) |
| 06H: | HD2 (DTV2) |
| 07H: | RGB 1 /PC 1 |
| 08H: | RGB 2 /PC 2 |
50. Failure Mode Request
Function
The external control equipment inquires the detection of failures of the plasma monitor.
Transmission Data
1FH 80H 60H 3FH 00H CKS
ACK
The plasma monitor returns the following ACK:
7FH 60H 80H 3FH 02H DATA00 DATA01 CKS
DATA00: FAILURE MODE 1
Bit 0 : PDP MODULE
0:Abnormal
1:Normal
Bit 1 : 1: fixed (backup)
Bit 2 : TEMPERATURE
0:Abnormal
1:Normal
Bit 3 : FAN
0:Abnormal
1:Normal
Bit 4 : 1: fixed (backup)
Bit 5 : 1: fixed (backup)
Bit 6 : 1: fixed (backup)
Bit 7 : 1: fixed (backup)
DATA01: FAILURE MODE 2
Bit
51. MODEL NAME Request
Function
The external control equipment inquires the product code of the plasma monitor.
Transmission Data
1FH 80H 60H 17H 00H CKS
ACK
The plasma monitor returns the following ACK:
| 7FH 60H 80H 17H | 0CH DATA00 to | DATA11 CKS | |||||
DATA00 : 1st character of the product code |
|
| ||||||
DATA01 : 2nd character of the product code |
|
| ||||||
DATA11 : 12th character of the product code |
|
| ||||||
|
|
|
|
|
|
|
|
|
NOTE: |
|
|
|
|
| |||
|
|
|
|
|
|
|
| |
| Received data (Hex) |
| Corresponding character | |||||
|
|
|
|
|
|
|
|
|
| 00H |
| 0 |
|
| |||
| 01H |
| 1 |
|
| |||
|
|
|
|
|
|
|
|
|
| 08H |
| 8 |
|
| |||
| 09H |
| 9 |
|
| |||
| 10H |
| A |
|
| |||
| 11H |
| B |
|
| |||
| 12H |
| C |
|
| |||
|
|
|
|
|
|
|
|
|
| 28H |
| Y |
|
| |||
| 29H |
| Z |
|
| |||
| 80H |
| - (Hyphen) |
| ||||
| 96H |
| (Blank) |
|
| |||
|
|
|
|
|
|
|
|
|
If there are fewer than 12 characters in the product code, product code would be padded right with blanks.
Example: If the product code of your plasma monitor is
DATA00: 1FH
DATA01: 27H
DATA02: 80H
DATA03: 05H
DATA04: 00H
DATA05: 27H
DATA06: 1CH
DATA07: 02H
DATA08: 10H
DATA09: 96H
DATA10: 96H
DATA11: 96H