Brightness and Contrast controls are interactive. A change to one

Note may require a subtle change to the other in order to achieve the optimum setting.

Color: To adjust the overall color intensity, select Color from the Main menu. Decrease this setting if colors are overly saturated; increase it if colors appear muted or washed out.

Color Tint: Tint or “hue” is the ratio of red to green in the color portion of the image. To adjust the tint, select Color Tint from the Main menu. Decrease this setting to shift the hue toward red; increase it to shift the hue toward green.

Like the Brightness and Contrast controls, the color and tint controls

Note are interactive. A change to one may require a subtle change to the other in order to achieve the optimum setting.

Sharpness: “Sharpness” is the amount of high-frequency detail in the image. To adjust this, select Sharpness from the Main menu and press ENTER. On your external test pattern source, select a pattern like the one shown in Figure 4-5.

Figure 4-5. Typical Test Pattern for Adjusting Sharpness

Sharpness (Simple Mode): Adjust as needed, looking for white edges around the transitions from black to gray and differently-sized lines in the “sweep” patterns at the top and bottom. Lower the sharpness setting to eliminate them.

Runco LS-3/LS-5 Installation/Operation Manual

47

Image 63
Contents LS-3 LS-3/CineWide LS-5 LS-5/CineWide LS-3 Series LS-5 SeriesPage RuncoCare Standard Features RuncoCare Standard Two Year Limited WarrantyRuncoCare Claim Procedure Page Copyright and Trademarks Important Safety Instructions Declaration of Conformity Compliance InformationFCC Part Page Table of Contents Operation Maintenance and TroubleshootingSerial Communications SpecificationsTable of Contents Xiv List of Figures List of Figures Xvi About This Manual IntroductionIf you need Turn to Using This ManualDescription, Features and Benefits Additional Features of the LS-5 LS-3/LS-5 at a Glance Controls and FunctionsSource LS-3/LS-5 Rear/Bottom/Top View Runco Logo Badge Page Page Projector on LS-3/LS-5 Remote ControlPIP Installation Remote ControlOperation IR Reception Angles For Details, Refer Quick SetupInstallation Overview Step ProcedureConsiderations InstallationProjector Installation Options Installation TypeThrow Distance Ambient LightThrow Ratios for the LS-3/LS-5 Series Vertical and HorizontalPosition Lens Shift Horizontal Lens Shift Example Only Installing the Optional CineWide Lens Mount Folded OpticsOther Considerations Installing the Fixed CineWide Base PlateDo not use the mounting screws provided with the ceiling Mounting the LS-3/LS-5 Connector Panel Access Connections toLS-3/LS-5 HDMI/DVI Connections See Figure Connecting Source Components to the LS-3/LS-5RGB Connections Page 11. Composite and S-Video Connections Connection RS-232 ControllerTheater Equipment Connecting 12-VoltConnecting an External IR Trigger Output to ExternalZoom Out Focus Zoom Turning on the Power Lens AdjustmentsConnecting to AC Power Focus and Zoom Lens ShiftInstallation Rear Projection Ceiling Mode Changing the OSD Language Adjusting the Picture OrientationIt is extremely important that the primary lens is properly Installing and Adjusting the CineWide Anamorphic LensAdjusting the Lens Height and Angle Correct Lens Angle Incorrect Lens Angle Selecting An Input Source OperationSelecting Video Memory Selecting an Aspect RatioMain Using Picture-In-Picture PIPAvailable Main and PIP Source Combinations PIP Input SourceUsing the On-Screen Menus LS-3/LS-5 OSD Menu Structure LS-3/LS-5 Main Menu Main169 Aspect Ratio SettingsNarrow 169Native You must enter a passcode to access the Save ISF Typical Pluge Pattern for Adjusting Brightness Typical Test Pattern for Adjusting Sharpness Operation Overscan Examples Source Select Sub-Menu LS-3/LS-5 Advanced Menu AdvancedOperation Color X/y Color Gamut ValuesRGB Adjust Sub-Menu 10. Fine Sync Sub-Menu Operation 11. LS-3/LS-5 System Menu System12. Source Enable Sub-Menu PBP1 PBP2 14. PIP Split-Screen Mode Control Page Language 15. LS-3/LS-5 Service Menu OSD menus are not available when in test pattern mode Operation Lamp Replacement Maintenance and TroubleshootingTroubleshooting Tips Troubleshooting ChartSymptom Possible Causes Solution Troubleshooting Chart Maintenance and Troubleshooting Serial Communications Key CommandsRS232 Remote Button IR Code Description Keyname Set Serial Command Key Names and IR CodesGam.crt Lit.tog Operations Control Commands Function Action on unitOperation Commands Values Serial CommandsSave.mem Source.sel = ? Satco = ? Auto.pow.off = ? Act.source Status Error Code LED Indication Description RS-232 Error CodesPage LS-3/LS-5 Specifications Universal Power Supply DimensionsWeight without lens Operating Temperature1shows the LS-3/LS-5 dimensions, in millimeters LS-3/LS-5 DimensionsSupported Timings Supported Signal Timings by InputPAL-B/G