Runco LS-3, LS-5 operation manual Serial Commands, Operation Commands Values

Page 91

Serial Communications

Decrement

-

Subtracts 1 from the current value.

 

 

 

Execute

(none)

Performs an action such as a reset.

 

 

 

Table 6-2lists the valid operations commands. For all but Execute functions, the response from the projector is the command and “= <value>” where <value> is the current value or “NA” if the value is not available. For Execute functions the response is the same command. All responses are in UPPERCASE.

Some operations command examples:

Input: op bright ? [CR]

 

Response: OP BRIGHT = 100

[CR]

Input: op bright + [CR]

 

Response: OP BRIGHT = 101

[CR]

Input: op bright = 127 [CR]

Response: OP BRIGHT = 127

[CR]

Input: op bright - [CR]

 

Response: OP BRIGHT = 126

[CR]

Input: op resync [CR]

 

Response: OP RESYNC [CR]

 

Input: op sharp.mode = 1 [CR]

Response: OP SHARP.MODE =

1 [CR]

Input: op sharp.simple = 50 [CR]

Response: OP SHARP.SIMPLE

= NA [CR]

Input: op sharp.simple ? [CR]

Response: OP SHARP.SIMPLE

= NA [CR]

The last three commands show what happens when a control is grayed out. In this case, the sharpness mode was set to advanced (value = 1) and then the simple sharpness slider was attempted to be adjusted and queried. The response was “NA” or not available.

Table 6-2. Serial Commands

Operation

Commands

Values

Notes

aspect

= ?

0 = 16:9

 

 

 

1

= Letterbox

 

 

 

2

= 4:3

 

 

 

3

= 4:3 Narrow

 

 

 

4

= Native

 

 

 

 

 

memory

= ?

0 = User Memory 1

? only returns a value if

 

 

1

= User Memory 2

ISF Day or ISF Night is

 

 

2

= ISF Day

active, otherwise it returns

 

 

3

= ISF Night

NA

 

 

4

= Default

 

Runco LS-3/LS-5 Installation/Operation Manual

75

Image 91
Contents LS-3 LS-3/CineWide LS-5 LS-5/CineWide LS-3 Series LS-5 SeriesPage RuncoCare Standard Features RuncoCare Standard Two Year Limited WarrantyRuncoCare Claim Procedure Page Copyright and Trademarks Important Safety Instructions Declaration of Conformity Compliance InformationFCC Part Page Table of Contents Operation Maintenance and TroubleshootingSerial Communications SpecificationsTable of Contents Xiv List of Figures List of Figures Xvi About This Manual IntroductionIf you need Turn to Using This ManualDescription, Features and Benefits Additional Features of the LS-5 LS-3/LS-5 at a Glance Controls and FunctionsSource LS-3/LS-5 Rear/Bottom/Top View Runco Logo Badge Page Page Projector on LS-3/LS-5 Remote ControlPIP Remote Control InstallationOperation IR Reception Angles For Details, Refer Quick SetupInstallation Overview Step ProcedureConsiderations InstallationProjector Installation Options Installation TypeThrow Distance Ambient LightVertical and Horizontal Throw Ratios for the LS-3/LS-5 SeriesPosition Lens Shift Horizontal Lens Shift Example Only Folded Optics Installing the Optional CineWide Lens MountOther Considerations CineWide Base Plate Installing the FixedDo not use the mounting screws provided with the ceiling Mounting the LS-3/LS-5 Connections to Connector Panel AccessLS-3/LS-5 HDMI/DVI Connections See Figure Connecting Source Components to the LS-3/LS-5RGB Connections Page 11. Composite and S-Video Connections Connection RS-232 ControllerTheater Equipment Connecting 12-VoltConnecting an External IR Trigger Output to ExternalZoom Out Focus Zoom Turning on the Power Lens AdjustmentsConnecting to AC Power Focus and Zoom Lens ShiftInstallation Rear Projection Ceiling Mode Changing the OSD Language Adjusting the Picture OrientationIt is extremely important that the primary lens is properly Installing and Adjusting the CineWide Anamorphic LensAdjusting the Lens Height and Angle Correct Lens Angle Incorrect Lens Angle Selecting An Input Source OperationSelecting Video Memory Selecting an Aspect RatioMain Using Picture-In-Picture PIPAvailable Main and PIP Source Combinations PIP Input SourceUsing the On-Screen Menus LS-3/LS-5 OSD Menu Structure LS-3/LS-5 Main Menu Main169 Aspect Ratio SettingsNarrow 169Native You must enter a passcode to access the Save ISF Typical Pluge Pattern for Adjusting Brightness Typical Test Pattern for Adjusting Sharpness Operation Overscan Examples Source Select Sub-Menu LS-3/LS-5 Advanced Menu AdvancedOperation Color X/y Color Gamut ValuesRGB Adjust Sub-Menu 10. Fine Sync Sub-Menu Operation 11. LS-3/LS-5 System Menu System12. Source Enable Sub-Menu PBP1 PBP2 14. PIP Split-Screen Mode Control Page Language 15. LS-3/LS-5 Service Menu OSD menus are not available when in test pattern mode Operation Lamp Replacement Maintenance and TroubleshootingTroubleshooting Chart Troubleshooting TipsSymptom Possible Causes Solution Troubleshooting Chart Maintenance and Troubleshooting Serial Communications Key CommandsRS232 Remote Button IR Code Description Keyname Set Serial Command Key Names and IR CodesGam.crt Lit.tog Operations Control Commands Function Action on unitOperation Commands Values Serial CommandsSave.mem Source.sel = ? Satco = ? Auto.pow.off = ? Act.source Status Error Code LED Indication Description RS-232 Error CodesPage LS-3/LS-5 Specifications Universal Power Supply DimensionsWeight without lens Operating Temperature1shows the LS-3/LS-5 dimensions, in millimeters LS-3/LS-5 DimensionsSupported Timings Supported Signal Timings by InputPAL-B/G