Runco LS-5, LS-3 operation manual Lit.tog, Operations Control Commands Function Action on unit

Page 90

Serial Communications

Table 6-1. Serial Command Key Names and IR Codes (continued)

RS232

Remote Button

IR Code

Description

 

 

Keyname

 

 

 

Set 1

Set 2

 

 

 

 

 

 

 

 

 

asp.16.9

(none)

0x9E

0xDE

Apply 16:9 aspect ratio to the active

 

 

 

 

source.

 

 

 

 

 

asp.4.3

(none)

0x9F

0xDF

Apply 4:3 aspect ratio to the active source.

 

 

 

 

 

asp.lett

(none)

0xA0

0xE0

Apply Letterbox aspect ratio to the active

 

 

 

 

source.

 

 

 

 

 

asp.narr

(none)

0xA1

0xE1

Apply 4:3 Narrow aspect ratio to the active

 

 

 

 

source.

 

 

 

 

 

pip.sw

 

0xA3

0xE3

Switch to next “PIP Select” state.

 

PIP

 

 

 

 

 

 

 

 

pip.1

(none)

0xA4

0xE4

Change “PIP Select” to source 1.

 

 

 

 

 

pip.2

(none)

0xA5

0xE5

Change “PIP Select” to source 2.

 

 

 

 

 

pip.3

(none)

0xA6

0xE6

Change “PIP Select” to source 3.

 

 

 

 

 

pip.4

(none)

0xA7

0xE7

Change “PIP Select” to source 4.

 

 

 

 

 

pip.5

(none)

0xA8

0xE8

Change “PIP Select” to source 5.

 

 

 

 

 

pip.off

(none)

0xA9

0xE9

Change “PIP Select” to off.

 

 

 

 

 

pip.swap

SWAP

0xAA

0xEA

Swap the PIP image with the active source

 

 

 

 

image.

 

 

 

 

 

pow.tog

(none)

0xAC

0xEC

Toggles between power on and power off.

 

 

 

 

 

lit.tog

LIGHT

0xAD

0xED

Activates remote backlighting only when

 

 

 

 

pressed momentarily. When held for five

 

 

 

 

seconds or more, the IR code for toggling

 

 

 

 

the projector I/O panel light is transmitted.

 

 

 

 

 

Operations Commands Operations commands allow more flexible and direct control of the projector. The syntax for operations commands is as follows:

op <operation> <command>[CR]

(Precede <operation> and <command> with a space.)

The command type can be one of 5 functions:

Operations Control Commands

Function

Command

Action on unit

 

 

 

Set

= <value>

Makes the unit take that value.

 

 

 

Get

?

Asks what the current value is.

 

 

 

Increment

+

Adds 1 to the current value.

 

 

 

74

Runco LS-3/LS-5 Installation/Operation Manual

Image 90
Contents LS-3 Series LS-5 Series LS-3 LS-3/CineWide LS-5 LS-5/CineWidePage RuncoCare Standard Two Year Limited Warranty RuncoCare Standard FeaturesRuncoCare Claim Procedure Page Copyright and Trademarks Important Safety Instructions Compliance Information Declaration of ConformityFCC Part Page Table of Contents Maintenance and Troubleshooting OperationSpecifications Serial CommunicationsTable of Contents Xiv List of Figures List of Figures Xvi Introduction About This ManualUsing This Manual If you need Turn toDescription, Features and Benefits Additional Features of the LS-5 Controls and Functions LS-3/LS-5 at a GlanceSource LS-3/LS-5 Rear/Bottom/Top View Runco Logo Badge Page Page LS-3/LS-5 Remote Control Projector onPIP Installation Remote ControlOperation IR Reception Angles Step Procedure Quick SetupInstallation Overview For Details, ReferInstallation Type InstallationProjector Installation Options ConsiderationsAmbient Light Throw DistanceThrow Ratios for the LS-3/LS-5 Series Vertical and HorizontalPosition Lens Shift Horizontal Lens Shift Example Only Installing the Optional CineWide Lens Mount Folded OpticsOther Considerations Installing the Fixed CineWide Base PlateDo not use the mounting screws provided with the ceiling Mounting the LS-3/LS-5 Connector Panel Access Connections toLS-3/LS-5 Connecting Source Components to the LS-3/LS-5 HDMI/DVI Connections See FigureRGB Connections Page 11. Composite and S-Video Connections RS-232 Controller ConnectionTrigger Output to External Connecting 12-VoltConnecting an External IR Theater EquipmentFocus and Zoom Lens Shift Turning on the Power Lens AdjustmentsConnecting to AC Power Zoom Out Focus ZoomInstallation Changing the OSD Language Adjusting the Picture Orientation Rear Projection Ceiling ModeInstalling and Adjusting the CineWide Anamorphic Lens It is extremely important that the primary lens is properlyAdjusting the Lens Height and Angle Correct Lens Angle Incorrect Lens Angle Selecting an Aspect Ratio OperationSelecting Video Memory Selecting An Input SourcePIP Input Source Using Picture-In-Picture PIPAvailable Main and PIP Source Combinations MainUsing the On-Screen Menus LS-3/LS-5 OSD Menu Structure Main LS-3/LS-5 Main MenuAspect Ratio Settings 169169 NarrowNative You must enter a passcode to access the Save ISF Typical Pluge Pattern for Adjusting Brightness Typical Test Pattern for Adjusting Sharpness Operation Overscan Examples Source Select Sub-Menu Advanced LS-3/LS-5 Advanced MenuOperation X/y Color Gamut Values ColorRGB Adjust Sub-Menu 10. Fine Sync Sub-Menu Operation System 11. LS-3/LS-5 System Menu12. Source Enable Sub-Menu PBP1 PBP2 14. PIP Split-Screen Mode Control Page Language 15. LS-3/LS-5 Service Menu OSD menus are not available when in test pattern mode Operation Maintenance and Troubleshooting Lamp ReplacementTroubleshooting Tips Troubleshooting ChartSymptom Possible Causes Solution Troubleshooting Chart Maintenance and Troubleshooting Key Commands Serial CommunicationsSerial Command Key Names and IR Codes RS232 Remote Button IR Code Description Keyname SetGam.crt Operations Control Commands Function Action on unit Lit.togSerial Commands Operation Commands ValuesSave.mem Source.sel = ? Satco = ? Auto.pow.off = ? Act.source Status RS-232 Error Codes Error Code LED Indication DescriptionPage LS-3/LS-5 Specifications Operating Temperature DimensionsWeight without lens Universal Power SupplyLS-3/LS-5 Dimensions 1shows the LS-3/LS-5 dimensions, in millimetersSupported Signal Timings by Input Supported TimingsPAL-B/G