Runco LS-3, LS-5 operation manual Serial Communications, Key Commands

Page 87

Serial Communications

6. Serial Communications

To interface the LS-3/LS-5 with a home theater automation/control system or a PC running terminal emulation software:

1.Connect it to your control system or PC as shown in Figure 3-12.

2.Start a terminal session on your PC using a terminal-emulation program, such as HyperTerminal.

3.Configure the RS-232 controller or PC serial port as follows: 38400 bps, no parity, 8 data bits, 1 stop bit and no flow control.

4.Type ky or op followed by a command from among those listed in Table 6-1or Table 6-2and press <Enter>. For example, to change the aspect ratio to Letterbox, type op aspect = 1<Enter>.

Serial commands to the LS-3/LS-5 take the following form:

Commands are in ASCII format.

Spaces and tabs can be used to improve readability and are ignored by the projector.

All commands must end with a carriage return (ASCII hex 0D) to signify that the projector can now read and execute the command.

Commands are not case-sensitive.

The LS-3/LS-5 supports two types of commands: key commands and operation commands. Key commands mimic pressing a button on the remote control. Operation commands tell the projector exactly what to do.

All commands start with 2 letters: ky for key commands.

op for operations commands.

The syntax for key commands is simple:

 

ky <keyname>[CR]

 

Some key command examples:

 

ky menu[CR]

Bring up or cancel menu display.

ky mem.sw[CR]

Switch to next user memory.

ky asp.16.9[CR]

Apply 16:9 aspect ratio.

The response from the projector for key commands will be the same command in

UPPERCASE.

Input: ky mem.sw[CR]

Response: KY MEM.SW [CR]

6.1

RS-232 Connection and Port Configuration

6.2

Serial Command Syntax

Key Commands

Runco LS-3/LS-5 Installation/Operation Manual

71

Image 87
Contents LS-3 LS-3/CineWide LS-5 LS-5/CineWide LS-3 Series LS-5 SeriesPage RuncoCare Standard Features RuncoCare Standard Two Year Limited WarrantyRuncoCare Claim Procedure Page Copyright and Trademarks Important Safety Instructions Declaration of Conformity Compliance InformationFCC Part Page Table of Contents Operation Maintenance and TroubleshootingSerial Communications SpecificationsTable of Contents Xiv List of Figures List of Figures Xvi About This Manual IntroductionIf you need Turn to Using This ManualDescription, Features and Benefits Additional Features of the LS-5 LS-3/LS-5 at a Glance Controls and FunctionsSource LS-3/LS-5 Rear/Bottom/Top View Runco Logo Badge Page Page Projector on LS-3/LS-5 Remote ControlPIP Installation Remote ControlOperation IR Reception Angles For Details, Refer Quick SetupInstallation Overview Step ProcedureConsiderations InstallationProjector Installation Options Installation TypeThrow Distance Ambient LightThrow Ratios for the LS-3/LS-5 Series Vertical and HorizontalPosition Lens Shift Horizontal Lens Shift Example Only Installing the Optional CineWide Lens Mount Folded OpticsOther Considerations Installing the Fixed CineWide Base PlateDo not use the mounting screws provided with the ceiling Mounting the LS-3/LS-5 Connector Panel Access Connections toLS-3/LS-5 HDMI/DVI Connections See Figure Connecting Source Components to the LS-3/LS-5RGB Connections Page 11. Composite and S-Video Connections Connection RS-232 ControllerTheater Equipment Connecting 12-VoltConnecting an External IR Trigger Output to ExternalZoom Out Focus Zoom Turning on the Power Lens AdjustmentsConnecting to AC Power Focus and Zoom Lens ShiftInstallation Rear Projection Ceiling Mode Changing the OSD Language Adjusting the Picture OrientationIt is extremely important that the primary lens is properly Installing and Adjusting the CineWide Anamorphic LensAdjusting the Lens Height and Angle Correct Lens Angle Incorrect Lens Angle Selecting An Input Source OperationSelecting Video Memory Selecting an Aspect RatioMain Using Picture-In-Picture PIPAvailable Main and PIP Source Combinations PIP Input SourceUsing the On-Screen Menus LS-3/LS-5 OSD Menu Structure LS-3/LS-5 Main Menu Main169 Aspect Ratio SettingsNarrow 169Native You must enter a passcode to access the Save ISF Typical Pluge Pattern for Adjusting Brightness Typical Test Pattern for Adjusting Sharpness Operation Overscan Examples Source Select Sub-Menu LS-3/LS-5 Advanced Menu AdvancedOperation Color X/y Color Gamut ValuesRGB Adjust Sub-Menu 10. Fine Sync Sub-Menu Operation 11. LS-3/LS-5 System Menu System12. Source Enable Sub-Menu PBP1 PBP2 14. PIP Split-Screen Mode Control Page Language 15. LS-3/LS-5 Service Menu OSD menus are not available when in test pattern mode Operation Lamp Replacement Maintenance and TroubleshootingTroubleshooting Tips Troubleshooting ChartSymptom Possible Causes Solution Troubleshooting Chart Maintenance and Troubleshooting Serial Communications Key CommandsRS232 Remote Button IR Code Description Keyname Set Serial Command Key Names and IR CodesGam.crt Lit.tog Operations Control Commands Function Action on unitOperation Commands Values Serial CommandsSave.mem Source.sel = ? Satco = ? Auto.pow.off = ? Act.source Status Error Code LED Indication Description RS-232 Error CodesPage LS-3/LS-5 Specifications Universal Power Supply DimensionsWeight without lens Operating Temperature1shows the LS-3/LS-5 dimensions, in millimeters LS-3/LS-5 DimensionsSupported Timings Supported Signal Timings by InputPAL-B/G