Runco LS-5, LS-3 Using Picture-In-Picture PIP, Available Main and PIP Source Combinations

Page 54

Operation

4.4 Using

Picture-In-Picture (PIP)

For PIP purposes, there are three groups of inputs

 

 

 

separated by their display modes:

PIP

SWAP

LIGHT

 

Video (SD) group: Video, S-Video and SCART inputs.

Graphic (HD) group: Component 1, Component 2 and RGB inputs.

Digital Video group: HDMI 1 and HDMI 2 inputs.

PIP shows one input from any of these groups within or beside one input from either of the other two groups.

Press PIP to enable the PIP function. Once enabled, press PIP repeatedly to select the desired PIP source or turn PIP off.

Press SWAP to swap the main and PIP images.

For more information, refer to PIP Position on page 59.

For each source, Table 4-1shows which of the other sources are available as a PIP source.

Table 4-1. Available Main and PIP Source Combinations

 

 

 

 

PIP Input Source

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VIDEO

S-VIDEO

SCART

COMP 1

COMP 2

RGB

HDMI

HDMI

 

 

2

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VIDEO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S-VIDEO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

InputSource

COMPSCART1

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

Main

COMP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RGB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

HDMI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

HDMI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

1. “” means that that source is available as a PIP source with a given main source; “–” means that it is not.

2. Disabled sources (refer to Source Enable on page 58) are not available as PIP sources.

38

Runco LS-3/LS-5 Installation/Operation Manual

Image 54
Contents LS-3 Series LS-5 Series LS-3 LS-3/CineWide LS-5 LS-5/CineWidePage RuncoCare Standard Two Year Limited Warranty RuncoCare Standard FeaturesRuncoCare Claim Procedure Page Copyright and Trademarks Important Safety Instructions Compliance Information Declaration of ConformityFCC Part Page Table of Contents Maintenance and Troubleshooting OperationSpecifications Serial CommunicationsTable of Contents Xiv List of Figures List of Figures Xvi Introduction About This ManualUsing This Manual If you need Turn toDescription, Features and Benefits Additional Features of the LS-5 Controls and Functions LS-3/LS-5 at a GlanceSource LS-3/LS-5 Rear/Bottom/Top View Runco Logo Badge Page Page LS-3/LS-5 Remote Control Projector onPIP Installation Remote ControlOperation IR Reception Angles Step Procedure Quick SetupInstallation Overview For Details, ReferInstallation Type InstallationProjector Installation Options ConsiderationsAmbient Light Throw DistanceThrow Ratios for the LS-3/LS-5 Series Vertical and HorizontalPosition Lens Shift Horizontal Lens Shift Example Only Installing the Optional CineWide Lens Mount Folded OpticsOther Considerations Installing the Fixed CineWide Base PlateDo not use the mounting screws provided with the ceiling Mounting the LS-3/LS-5 Connector Panel Access Connections toLS-3/LS-5 Connecting Source Components to the LS-3/LS-5 HDMI/DVI Connections See FigureRGB Connections Page 11. Composite and S-Video Connections RS-232 Controller ConnectionTrigger Output to External Connecting 12-VoltConnecting an External IR Theater EquipmentFocus and Zoom Lens Shift Turning on the Power Lens AdjustmentsConnecting to AC Power Zoom Out Focus ZoomInstallation Changing the OSD Language Adjusting the Picture Orientation Rear Projection Ceiling ModeInstalling and Adjusting the CineWide Anamorphic Lens It is extremely important that the primary lens is properlyAdjusting the Lens Height and Angle Correct Lens Angle Incorrect Lens Angle Selecting an Aspect Ratio OperationSelecting Video Memory Selecting An Input SourcePIP Input Source Using Picture-In-Picture PIPAvailable Main and PIP Source Combinations MainUsing the On-Screen Menus LS-3/LS-5 OSD Menu Structure Main LS-3/LS-5 Main MenuAspect Ratio Settings 169169 NarrowNative You must enter a passcode to access the Save ISF Typical Pluge Pattern for Adjusting Brightness Typical Test Pattern for Adjusting Sharpness Operation Overscan Examples Source Select Sub-Menu Advanced LS-3/LS-5 Advanced MenuOperation X/y Color Gamut Values ColorRGB Adjust Sub-Menu 10. Fine Sync Sub-Menu Operation System 11. LS-3/LS-5 System Menu12. Source Enable Sub-Menu PBP1 PBP2 14. PIP Split-Screen Mode Control Page Language 15. LS-3/LS-5 Service Menu OSD menus are not available when in test pattern mode Operation Maintenance and Troubleshooting Lamp ReplacementTroubleshooting Tips Troubleshooting ChartSymptom Possible Causes Solution Troubleshooting Chart Maintenance and Troubleshooting Key Commands Serial CommunicationsSerial Command Key Names and IR Codes RS232 Remote Button IR Code Description Keyname SetGam.crt Operations Control Commands Function Action on unit Lit.togSerial Commands Operation Commands ValuesSave.mem Source.sel = ? Satco = ? Auto.pow.off = ? Act.source Status RS-232 Error Codes Error Code LED Indication DescriptionPage LS-3/LS-5 Specifications Operating Temperature DimensionsWeight without lens Universal Power SupplyLS-3/LS-5 Dimensions 1shows the LS-3/LS-5 dimensions, in millimetersSupported Signal Timings by Input Supported TimingsPAL-B/G