Runco LS-10I operation manual OSD menus are not available when in test pattern mode

Page 85

Operation

Lamp Hour Reset: When you replace the projector lamp (refer to Lamp Replacement on page 71), you should also reset the lamp hour counter. To do this, select Lamp Hour Reset from the Service menu, then press ENTER. Press ENTER again to confirm the reset. Or, to cancel the operation, press on the remote to highlight No, then press

ENTER.

Note

WARNING

Reset the Lamp Hour counter ONLY after you replace the lamp. Otherwise, the reported “Lamp Hours” will be inaccurate.

Do not exceed the recommended lamp life. An old lamp becomes increasingly fragile and prone to sudden failure.

Factory Reset: Select Factory Reset from the Service menu to restore all projector settings – except those listed below – to their factory-default values:

Lamp Hours

Custom 1 / Custom 2

ISF Day

ISF Night

Model Name / Serial Number

Language

Blue Only: This feature removes all red and green color information from the image, and is useful for color-calibrating the projector or other video components.

Test Patterns: The LS-10i has numerous internal test patterns that are useful to technicians for advanced calibration, measurement and fault isolation purposes. To access them, select Test Patterns from the Service menu and set it to On.

The available test patterns are:

White

Black

Red

Green

Blue

Cyan

Magenta

Yellow

ANSI Checkerboard

Horizontal Gray Ramp

Focus Grid

Press or on the remote control unit or built-in keypad to cycle through the test patterns.

The OSD menus are not available when in “test pattern” mode.

Note

Runco LS-10i Installation/Operation Manual

69

Image 85
Contents LS-10i Page RuncoCare Standard Features RuncoCare Standard Two Year Limited WarrantyRuncoCare Claim Procedure Extended Service Options Copyright and Trademarks Important Safety Instructions Declaration of Conformity Compliance InformationFCC Part Page Table of Contents Operation Specifications Maintenance and TroubleshootingExternal Control Table of Contents Xiv List of Figures List of Figures About This Manual IntroductionIf you need Turn to Using This ManualFormat screen Description, Features and BenefitsOptional Accessories LS-10i at a Glance Controls and FunctionsCursor Keys Press this button to show or hide the OSD menusExhaust Vent Runco Logo Badge Rear Cover RGB LS-10i Rear PanelLS-10i Remote Control Memory Preset Buttons Picture Adjustment Buttons BRT BrightnessContrast COL Color169 Aspect Ratio Selection ButtonsLbox Letterbox Vwide VirtualWideControls and Functions Remote Control InstallationIR Reception Angles Installation Overview Quick SetupStep Procedure For Details, ReferProjector Installation Options InstallationInstallation Type ConsiderationsThrow Distance Ambient LightEstimating Throw Distance Throw Range Throw Ratio Inches, with LS-10i Lens Options and Throw Ratios NoteLens Option LensFloor Installation Ceiling InstallationVertical and Horizontal PositionHorizontal Lens Shift Example Only Package Contents Installing the Optional Anamorphic Lens MountFolded Optics Other Considerations Attaching the Transport Assembly Attachment Plate Position the attachment plate as shown here Ceiling Mount Plate Attachment Plate Projector bottom Do not OVER-TIGHTEN the ScrewsPlate Installation Mounting the LS-10i Angle Adjusting the ProjectionConnections to the LS-10i Connector Panel AccessComponents to the LS-10i Connecting SourceHDMI/DVI Connections See Figure HDMI/DVI sources BD, DVD DTV Set-Top Box, Game Console etcComputer RGB Camcorder Gaming Console 10. Scart Source ConnectionsDTV-Set-Top Box 11. Component Video Connections12. Composite and S-Video Connections Camcorder Gaming ConsoleConnection RS-232 ControllerTrigger Output to External Connecting 12-VoltTheater Equipment +12V Trigger InputConnecting to AC Power Connecting an External IRReceiver Appropriate to your localeFocus Zoom Lens Shift Turning on the Power Primary Lens AdjustmentsRear Projection Ceiling Mode Changing the OSD Language Adjusting the Picture OrientationInstallation See Figure Adjustment Installing and Adjusting the Anamorphic LensAdjusting the Lens Position Installation Selecting An Input OperationSource Selecting An Aspect Ratio Selecting Video MemoryAvailable Main and PIP Source Combinations Using Picture-In-Picture PIPPIP Input Source MainUsing the On-Screen Menus LS-10i Main Menu 169 Aspect Ratio SettingsLetterbox Virtual Cinema You must enter a passcode to access the Save ISF Typical Pluge Pattern for Adjusting Brightness Typical Test Pattern for Adjusting Sharpness Overscan Examples Input Select Sub-Menu LS-10i Advanced Menu AdvancedPCE Color Gamut setting refer to Color Gamut, below Color X/y Color Gamut ValuesRGB Adjust Sub-Menu 10. Fine Sync Sub-Menu 11. PCE Sub-Menu Red Gre en Yellow Cy anMagenta Blue 13. LS-10i System Menu 14. Input Enable Sub-Menu Top right 921x51816. PIP Split-Screen Mode 17. LS-10i Control Menu Language 18. LS-10i Service Menu OSD menus are not available when in test pattern mode Operation Lamp Replacement Maintenance and TroubleshootingTroubleshooting Chart Troubleshooting TipsSymptom Possible Causes Solution Troubleshooting Chart Maintenance and Troubleshooting External Control RS-232 Connection Port Configuration Serial Command SyntaxSerial Communications Some key command examples Serial Command Key Names and IR CodesSwitch to next user memory Apply 169 aspect ratioRemote Button IR Code RS232 Keyname0x08 = value Operations Control Commands Function Action on unitOperation Commands Values Serial CommandsColor.space = ? Vert.pos = ? + Key = ? Cinewide = ? Cal.text1 Error Code LED Indication Description RS-232 Error CodesCEC Commands Supported by the LS-10i Using Hdmi CEC MessagesCEC Command List Opcode ValueInactive Source 0x9D CEC Version LS-10i Specifications SpecificationsLS-10i Specifications Proteus 1 None Proteus 2, 3, 4, 5HDTV, EDTV, Sdtv Industry-Standard Specifications Home Theater Calibration SpecificationsSpecifications are subject to change without notice LS-10i Dimensions LS-10i DimensionsSupported Timings Supported Signal Timings by InputPAL-B/G Page 020-1075-00 Rev. a September