Network Requirements

Before installing the module, review the requirements and specifications referred to in this chapter concerning the following:

Port Trunking (Section 2.1)

10BASE-T Twisted Pair Network (Section 2.2)

100BASE-T Twisted Pair Network (Section 2.3)

The network installation must meet the requirements to ensure satisfactory performance of this equipment. Failure to do so will produce poor network performance.

NOTE: The MATRIX E5 Series Modules Local Management User’s Guide and Cabling Guide referred to in the following sections can be found on the Enterasys Networks World Wide Web site: http://www.enterasys.com/

2.1PORT TRUNKING FEATURE

Before connecting the module to a network so it can take advantage of the Port Trunking feature, there are certain rules concerning port connections and configurations that must be followed for proper operation. Refer to the MATRIX E5 Series Modules Local Management User’s Guide for additional information.

2.210BASE-T NETWORK

When connecting a 10BASE-T segment to any of the module ports (1 through 48), ensure that the network meets the Ethernet network requirements of the IEEE 802.3 standard for 10BASE-T. Refer to the Cabling Guide for details.

NOTE: If a port is to operate at 100 Mbps, Category 5 cabling must be used. Category 3 cabling does not meet 100 Mbps specifications. For 10 Mbps operation only, Category 3 or Category 5 cabling can be used. Refer to Section 2.3 for information about 100BASE-TX networks and cabling.

Network Requirements

2-1

Image 23
Contents 5H102-48 and 5H103-48 Fast Ethernet Installation Guide Page Page Vcci Notice FCC NoticeIndustry Canada Notice Iii Enterasys NETWORKS, INC Program License AgreementPage Declaration of Conformity Page Contents Troubleshooting Figures Tables Structure of this Guide Using this GuideAbout This Guide Related Documents Guide uses the following conventions Document ConventionsYour email address Getting HelpIntroduction Introduction5H102-48 and 5H103-48 Modules Remote Monitoring Rmon ConnectivityHALF-DUPLEX/FULL-DUPLEX AUTO-NEGOTIATION Port TrunkingManagement PORT/VLAN Redirect FunctionFlow Control 802.1 Port PriorityStandards Compatibility Switching OptionsPage 10BASE-T Network Port Trunking FeatureNetwork Requirements 100BASE-TX Network Unpacking the Module InstallationQuantity Installing the Module Into the 5C105 Chassis Installing a Module into the 5C105 Chassis Connecting UTP Cables to the 5H102-48 Connecting to the NetworkConnecting a Twisted Pair Segment to the 5H102-48 Crossover Cable RJ45 Pinouts Connecting UTP Cables to the 5H103-48 Connection Using the RJ21 Angle Adapter Completing the Installation Using Lanview TroubleshootingLanview LEDs both modules CPU Is enabled and there is a OFF Troubleshooting ChecklistLocal Management User’s Guide for the IP Reset Button both modules Using the Reset ButtonPage Environmental Requirements SpecificationsModule Specifications Physical PropertiesCOM Port Pinout Assignments INPUT/OUTPUT PortsRegulatory Compliance Page Required Tools Mode Switch Bank Settings and OptionsFigure B-1 Mode Switch Location Setting the Mode SwitchesSetting the Mode Switches Page Numerics IndexIndex-2