Troubleshooting Checklist
Table
Problem | Possible Cause | Recommended Action | |
|
|
| |
Cannot contact | IP address not assigned. | Refer to the MATRIX E5 Series Modules | |
the module |
| Local Management User’s Guide for the IP | |
through |
| address assignment procedure. | |
management. |
|
| |
Port is disabled. | Enable port. Refer to the MATRIX E5 Series | ||
| |||
|
| Modules Local Management User’s Guide | |
|
| for instructions to enable/disable ports. | |
|
|
| |
| No link to device. | 1. Verify that all network connections | |
|
| between the network management station | |
|
| and the module are valid and operating. | |
|
| 2. If the problem continues, contact Enterasys | |
|
| Networks for technical support. | |
|
|
| |
Port(s) goes into | Loop condition detected. | 1. Verify that Spanning Tree is enabled. | |
standby for no |
| Refer to the MATRIX E5 Series Modules | |
apparent reason. |
| Local Management User’s Guide for the | |
|
| instructions to set the type of STA. | |
|
| 2. Review the network design and delete | |
|
| unnecessary loops. | |
|
| 3. If the problem continues, contact Enterasys | |
|
| Networks for technical support. | |
|
|
| |
User parameters | 1. Position of Mode switch | 1. Reenter the lost parameters as necessary. | |
(IP address, | (7), NVRAM Reset, was | Refer to the MATRIX E5 Series Modules | |
Device and | changed sometime | Local Management User’s Guide for the | |
Module name, | before either cycling | instructions to configure the device | |
etc.) were lost | power or pressing the | through Local Management. | |
when the module | RESET button, causing | 2. If the problem continues, contact Enterasys | |
power was cycled | the | Networks for technical support. | |
or the front panel | parameters to reset to |
| |
RESET button | factory default settings. |
| |
was pressed. | 2. Clear NVRAM was set |
| |
| through Local |
| |
| Management. |
| |
|
|
|