Runco SP-42DHD, SP-60DHD, SP-50DHD manual Using This Manual, If you need Turn to

Page 12

Introduction

Graphic Conventions: These symbols appear in numerous places throughout the manual, to emphasize points that you must keep in mind to avoid problems with your equipment or injury:

Tip

TIPS highlight time-saving short cuts and helpful guidelines for using

certain features.

Note

NOTES emphasize text with unusual importance or special

significance. They also provide supplemental information.

Caution

CAUTIONS alert users that a given action or omitted action can

degrade performance or cause a malfunction.

 

WARNING

WARNINGS appear when a given action or omitted action can result

in damage to the equipment, or possible non-fatal injury to the user.

DANGER!

DANGER appears when a given action can cause severe injury or

death.

 

1.2

Using This Manual

Use the following table to locate the specific information you need in this manual.

If you need...

... Turn to page:

 

 

Information about obtaining service

iv

 

 

General information about the PlasmaWall

3

Flat-Panel Plasma Display Monitor and DHD Con-

 

troller

 

 

 

Installation instructions

17

 

 

First-time configuration instructions

31

 

 

Advanced configuration instructions

43

 

 

Troubleshooting tips

50

 

 

Specifications for the PlasmaWall Flat-Panel

59

Plasma Display Monitor and DHD Controller

 

 

 

2

PlasmaWall SP Series Owner’s Operating Manual

Image 12
Contents SP-42DHD SP-50DHD SP-60DHD Page Three Year Limited Warranty For Plasma DisplaysRIGHTS, Limits and Exclusions Runco INTERNATIONAL, INC Safety Precautions Table of Contents Maintenance and Troubleshooting SpecificationsAppendix A. PlasmaWall Service Remote Control OperationList of Figures List of Figures Introduction About This ManualUsing This Manual If you need Turn toDescription, Features and Benefits Key Features and BenefitsOptional Accessories Controls and Indicators Controls and FunctionsPlasmaWall at a Glance PlasmaWall Model SP-42DHD Rear Panel PlasmaWall Model SP-50DHD Rear Panel PlasmaWall Model SP-60DHD Rear Panel Main Power Switch Digital RGB Input 2 DVI-DExternal Speaker Output Right External Speaker Output LeftPower Button DHD Controller Front PanelRunco Icon IR SensorUP Button Left ButtonEnter Button Down ButtonComponent Video RCA connectors DHD Controller Rear PanelDVI OUT Inputs 3. DVI 1 / DVI 2 DigitalComposite Video Input RS-232 Control PortMain AC Fuse DHD Controller Remote Control DHD Controller Remote ControlIR Output Indicator EnterLight MenuCinema SVCISF Night ISF DAYInstallation Remote ControlOther surfaces Quick Setup Step Procedure For Details, refer toInstallation ConsiderationsHigh-Altitude Operation Mounting the PlasmaWallAmbient Light VentilationInstallation Connecting PlasmaWall to the DHD Controller Connections to the PlasmaWall and DHD ControllerRS-232 Connection from the DHD Controller to the PlasmaWall Connecting Source Components to the DHDDVI Connections See Figure DVI Source DVD Player or HD Tuner with Hdmi or DVI outDigital DTV RGB Connections See Digital DTV RGB ConnectionsRefer to Computer/Video Signal Compatibility on page 64 for Analog Computer RGB Connections See FigurePersonal Computer Composite/S-Video/Component Video Connections See Figure DVD Player, VCR Satellite Receiver Laser Disc etcConnecting 12-Volt Trigger Outputs to External Equipment RS-232 ControllerConnection 11. Installing the Cable Ties Turning on the Power OperationYou must enter a passcode to access the Service menu Operation Using the On-Screen Menus ISF Presets ServiceInput Source Aspect RatioMain Menu Input SourceAspect Ratio HD Pass Thru 1 HD Pass ThruAspect Ratio Settings Remote Aspect Ratio Control Description KeyPicture Picture Brightness Contrast Color Tint SharpnessTypical Gray Bar Pattern for Adjusting Contrast Gray Yellow Cyan Green Magenta Red Blue Input Position Input Position Left/Right Up/Down Width Height OverscanISF Presets ISF Presets ISF Night ISF Day Custom Save Factory DefaultInformation Serial Number Hardware Firmware 0002.034B Date Nov 25Gain/Offset Refer to ISF Night Display Color, above CalibrationService Should be used by ISF-certified technicians onlyInput Names Restore Composite Video Component SD HD/RGB 1 and HD/RGB 2 Color Space Select Auto, RGB or YUV Operation Operation Maintenance and Troubleshooting CleaningCleaning the Display Panel Body and Remote Control Cleaning the ScreenTroubleshooting Tips Symptom Possible Causes SolutionComputer/Video Signal Maintenance and Troubleshooting Serial Communications Letterbox EnterCommand Value Description Min/max Stored? Power On/Off CommandsInput Selection Commands Aspect Ratio CommandsImage Preset Commands Value Description Min/max Stored? Input Position Commands Output Shift CommandsBkgnd Command Parameter min/max Value Stored? Description Enter keySpecifications PlasmaWall SpecificationsModel SP-42DHD Model SP-50DHDDHD Controller Specifications Dimensions PlasmaWall14.8 34.3 49.1 M8 Screw Computer/Video Signal Compatibility Input Refresh Rate Resolution RemarksHoriz KHz56.0 45.1 Specifications Figure A-1. PlasmaWall Service Remote Control OverviewRGB Setup Aspect RatioRGB-HD DVI-DService/Setup Menu Video NR NoiseReduction PlasmaWall Service Remote Control Page Runco CL-810 Owner’s Operating Manual