Runco SP-42DHD, SP-60DHD, SP-50DHD Input Position Left/Right Up/Down Width Height Overscan

Page 51

Operation

Sharpness: “Sharpness” is the amount of high-frequency detail in the image. To adjust sharpness, select Sharpness from the Picture menu and press ENTER. On your external test pattern source, select a pattern like the one shown in Figure 4-5.Adjust as needed, looking for white edges around the transitions from black to gray and differently-sized lines in the “sweep” patterns at the top and bottom. Lower the sharpness setting to eliminate them.

Figure 4-5. Typical Test Pattern for Adjusting Sharpness

Use the controls in the Input Position Menu to fine-tune the aspect ratio and image position for the current source.

Note

The input position settings are automatically saved for each input

and resolution.

Left/Right: Select Left/Right from the Input Position menu to shift the projected image horizontally. Use the right or up cursor button to shift the image to the right; use the left or down button to shift it to the left.

Up/Down: Select Up/Down from the Input Position menu to shift the projected image vertically. Use the right or up cursor button to shift the image upward; use the left or down button to shift it downward.

Width: Select Width from the Input Position menu to change the projected image width. Use the right or up cursor button to increase the width; use the left or down button to decrease it.

Height: Select Height from the Input Position menu to change the projected image height. Use the right or up cursor button to increase the height; use the left or down button to decrease it.

Input Position

Input Position

Left/Right

Up/Down

Width

Height

Overscan

PlasmaWall SP Series Owner’s Operating Manual

41

Image 51
Contents SP-42DHD SP-50DHD SP-60DHD Page For Plasma Displays Three Year Limited WarrantyRIGHTS, Limits and Exclusions Runco INTERNATIONAL, INC Safety Precautions Table of Contents Operation Maintenance and TroubleshootingSpecifications Appendix A. PlasmaWall Service Remote ControlList of Figures List of Figures About This Manual IntroductionIf you need Turn to Using This ManualKey Features and Benefits Description, Features and BenefitsOptional Accessories Controls and Indicators Controls and FunctionsPlasmaWall at a Glance PlasmaWall Model SP-42DHD Rear Panel PlasmaWall Model SP-50DHD Rear Panel PlasmaWall Model SP-60DHD Rear Panel External Speaker Output Left Main Power SwitchDigital RGB Input 2 DVI-D External Speaker Output RightIR Sensor Power ButtonDHD Controller Front Panel Runco IconDown Button UP ButtonLeft Button Enter ButtonInputs 3. DVI 1 / DVI 2 Digital Component Video RCA connectorsDHD Controller Rear Panel DVI OUTComposite Video Input RS-232 Control PortMain AC Fuse DHD Controller Remote Control DHD Controller Remote ControlMenu IR Output IndicatorEnter LightISF DAY CinemaSVC ISF NightRemote Control InstallationOther surfaces Step Procedure For Details, refer to Quick SetupMounting the PlasmaWall InstallationConsiderations High-Altitude OperationVentilation Ambient LightInstallation Connections to the PlasmaWall and DHD Controller Connecting PlasmaWall to the DHD ControllerRS-232 Connection from the DHD Controller to the PlasmaWall DVI Source DVD Player or HD Tuner with Hdmi or DVI out Connecting SourceComponents to the DHD DVI Connections See FigureDigital DTV RGB Connections Digital DTV RGB Connections SeeRefer to Computer/Video Signal Compatibility on page 64 for Analog Computer RGB Connections See FigurePersonal Computer DVD Player, VCR Satellite Receiver Laser Disc etc Composite/S-Video/Component Video Connections See FigureConnecting 12-Volt Trigger Outputs to External Equipment RS-232 ControllerConnection 11. Installing the Cable Ties Operation Turning on the PowerYou must enter a passcode to access the Service menu Operation Using the On-Screen Menus Aspect Ratio ISF PresetsService Input SourceHD Pass Thru 1 HD Pass Thru Main MenuInput Source Aspect RatioRemote Aspect Ratio Control Description Key Aspect Ratio SettingsPicture Brightness Contrast Color Tint Sharpness PictureTypical Gray Bar Pattern for Adjusting Contrast Gray Yellow Cyan Green Magenta Red Blue Input Position Left/Right Up/Down Width Height Overscan Input PositionSerial Number Hardware Firmware 0002.034B Date Nov 25 ISF PresetsISF Presets ISF Night ISF Day Custom Save Factory Default InformationCalibration Gain/Offset Refer to ISF Night Display Color, aboveShould be used by ISF-certified technicians only ServiceInput Names Restore Composite Video Component SD HD/RGB 1 and HD/RGB 2 Color Space Select Auto, RGB or YUV Operation Operation Cleaning the Screen Maintenance and TroubleshootingCleaning Cleaning the Display Panel Body and Remote ControlSymptom Possible Causes Solution Troubleshooting TipsComputer/Video Signal Maintenance and Troubleshooting Letterbox Enter Serial CommunicationsAspect Ratio Commands CommandValue Description Min/max Stored? Power On/Off Commands Input Selection CommandsImage Preset Commands Output Shift Commands Value Description Min/max Stored? Input Position CommandsBkgnd Enter key Command Parameter min/max Value Stored? DescriptionModel SP-50DHD SpecificationsPlasmaWall Specifications Model SP-42DHDDHD Controller Specifications PlasmaWall Dimensions14.8 34.3 49.1 M8 Screw KHz Computer/Video Signal CompatibilityInput Refresh Rate Resolution Remarks Horiz56.0 45.1 Specifications Overview Figure A-1. PlasmaWall Service Remote ControlDVI-D RGB SetupAspect Ratio RGB-HDService/Setup Menu Video NR NoiseReduction PlasmaWall Service Remote Control Page Runco CL-810 Owner’s Operating Manual