Runco SP-60DHD, SP-42DHD manual DHD Controller Rear Panel, Dvi Out, Inputs 3. DVI 1 / DVI 2 Digital

Page 22

Controls and Functions

2.3

DHD Controller Rear Panel

Figure 2-6shows the rear connector panel on the DHD Controller.

4

8

10

Serial No

Runco International

Union City, CA

Model

OUTPUTS

R/PrG/YB/Pb

Video Processor / Controller

H

V

H/V

DVI Out

 

 

 

 

 

 

 

SYSTEM CONTROL INTERFACE

 

 

INPUTS

 

 

 

 

 

 

 

R/Pr

G/Y

B/Pb

H

V

 

 

 

 

 

 

 

 

 

 

 

 

TRIGGERS

 

 

 

 

 

 

 

HD1

 

 

 

 

 

 

 

 

 

 

1

2

3

IR

 

 

 

 

 

HD2

 

 

 

 

R/Pr

G/Y

B/Pb

H

V

 

 

 

WARNING: TO REDUCE THE RISK OF FIRE

 

 

 

 

OR ELECTRIC SHOCK, DO NOT EXPOSE

 

 

 

 

 

 

 

 

 

THIS APPLIANCE TO RAIN OR MOISTURE.

 

 

 

SDI

Pb

Pr

Y

S-Video 1

 

 

 

 

 

 

 

 

DVI 1

 

DVI 2

Option

 

Component Video

Video

S-Video 2

RS-232 Out

RS-232 Control

CAUTION

!

RISK OF ELECTRIC SHOCK

DO NOT OPEN

AVIS: RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER. NO USER- SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE CENTER.

100-230VAC 50-60 Hz, 165 Watts Max

Made In USA

1235 6 7 9 1112 13 14

Figure 2-6. DHD Controller Rear Panel

Outputs 1. ANALOG OUTPUTS (RGBHV)

Connect these to the ANALOG RGB IN input of the PlasmaWall, using a

5 x BNC-to-VGA breakout cable.

2.DVI OUT

Connect this to the DIGITAL RGB (DVI-D) input on the PlasmaWall.

Inputs 3. DVI 1 / DVI 2 (Digital)

Two, HDCP-compliant digital video inputs for connecting a DVD player or HD tuner with a DVI or HDMI output.

4.HD1 / HD2 (5 x Analog BNCs)

Two inputs (five BNCs per input) for connecting either RGB or component high-definition television signals. The DHD Controller automatically detects the signal format: RGB(HV) or YPrPb, 480p, 720p, 480i, 576i or 1080i.

5.COMPONENT VIDEO (RCA connectors)

Standard Definition (480i/576i) Component (YPrPb) input. This is the input for component video from sources such as DVD players.

For best results, do not run your DVD player in progressive mode.

Tip

12

PlasmaWall SP Series Owner’s Operating Manual

Image 22
Contents SP-42DHD SP-50DHD SP-60DHD Page Three Year Limited Warranty For Plasma DisplaysRIGHTS, Limits and Exclusions Runco INTERNATIONAL, INC Safety Precautions Table of Contents Appendix A. PlasmaWall Service Remote Control Maintenance and TroubleshootingSpecifications OperationList of Figures List of Figures Introduction About This ManualUsing This Manual If you need Turn toDescription, Features and Benefits Key Features and BenefitsOptional Accessories Controls and Functions Controls and IndicatorsPlasmaWall at a Glance PlasmaWall Model SP-42DHD Rear Panel PlasmaWall Model SP-50DHD Rear Panel PlasmaWall Model SP-60DHD Rear Panel External Speaker Output Right Main Power Switch Digital RGB Input 2 DVI-D External Speaker Output LeftRunco Icon Power ButtonDHD Controller Front Panel IR SensorEnter Button UP ButtonLeft Button Down ButtonDVI OUT Component Video RCA connectorsDHD Controller Rear Panel Inputs 3. DVI 1 / DVI 2 DigitalRS-232 Control Port Composite Video InputMain AC Fuse DHD Controller Remote Control DHD Controller Remote ControlLight IR Output IndicatorEnter MenuISF Night CinemaSVC ISF DAYInstallation Remote ControlOther surfaces Quick Setup Step Procedure For Details, refer toHigh-Altitude Operation InstallationConsiderations Mounting the PlasmaWallAmbient Light VentilationInstallation Connecting PlasmaWall to the DHD Controller Connections to the PlasmaWall and DHD ControllerRS-232 Connection from the DHD Controller to the PlasmaWall DVI Connections See Figure Connecting SourceComponents to the DHD DVI Source DVD Player or HD Tuner with Hdmi or DVI outDigital DTV RGB Connections See Digital DTV RGB ConnectionsAnalog Computer RGB Connections See Figure Refer to Computer/Video Signal Compatibility on page 64 forPersonal Computer Composite/S-Video/Component Video Connections See Figure DVD Player, VCR Satellite Receiver Laser Disc etcRS-232 Controller Connecting 12-Volt Trigger Outputs to External EquipmentConnection 11. Installing the Cable Ties Turning on the Power OperationYou must enter a passcode to access the Service menu Operation Using the On-Screen Menus Input Source ISF PresetsService Aspect RatioAspect Ratio Main MenuInput Source HD Pass Thru 1 HD Pass ThruAspect Ratio Settings Remote Aspect Ratio Control Description KeyPicture Picture Brightness Contrast Color Tint SharpnessTypical Gray Bar Pattern for Adjusting Contrast Gray Yellow Cyan Green Magenta Red Blue Input Position Input Position Left/Right Up/Down Width Height OverscanInformation ISF PresetsISF Presets ISF Night ISF Day Custom Save Factory Default Serial Number Hardware Firmware 0002.034B Date Nov 25Gain/Offset Refer to ISF Night Display Color, above CalibrationService Should be used by ISF-certified technicians onlyInput Names Restore Composite Video Component SD HD/RGB 1 and HD/RGB 2 Color Space Select Auto, RGB or YUV Operation Operation Cleaning the Display Panel Body and Remote Control Maintenance and TroubleshootingCleaning Cleaning the ScreenTroubleshooting Tips Symptom Possible Causes SolutionComputer/Video Signal Maintenance and Troubleshooting Serial Communications Letterbox EnterInput Selection Commands CommandValue Description Min/max Stored? Power On/Off Commands Aspect Ratio CommandsImage Preset Commands Value Description Min/max Stored? Input Position Commands Output Shift CommandsBkgnd Command Parameter min/max Value Stored? Description Enter keyModel SP-42DHD SpecificationsPlasmaWall Specifications Model SP-50DHDDHD Controller Specifications Dimensions PlasmaWall14.8 34.3 49.1 M8 Screw Horiz Computer/Video Signal CompatibilityInput Refresh Rate Resolution Remarks KHz56.0 45.1 Specifications Figure A-1. PlasmaWall Service Remote Control OverviewRGB-HD RGB SetupAspect Ratio DVI-DVideo NR Noise Service/Setup MenuReduction PlasmaWall Service Remote Control Page Runco CL-810 Owner’s Operating Manual