Maintenance and Troubleshooting
Table 5-1. Troubleshooting Chart (continued)
Symptom |
| Possible Cause(s) |
| Solution |
|
|
|
| |
Image appears “washed out” | • Brightness is set too high. | • | Lower the brightness | |
and/or dark areas appear too |
|
|
| setting. |
bright. |
|
|
|
|
|
|
| ||
Colors in the image are | • The Red/Pr, Green/Y or | • Ensure that the source | ||
swapped; for example, reds |
| Blue/Pb outputs from the |
| outputs are connected to |
appear blue or vice versa. |
| source are connected to |
| the correct DHD Controller |
|
| the wrong inputs on the |
| input. |
|
| DHD Controller. |
|
|
| • The Red, Green or Blue | • Ensure that the DHD | ||
|
| (analog) outputs from the |
| Controller outputs are |
|
| DHD Controller are |
| connected to the correct |
|
| connected to the wrong |
| inputs on the PlasmaWall. |
|
| inputs on the PlasmaWall. |
|
|
|
|
| ||
• Clock and Phase settings | • Adjust Clock and Phase | |||
“noisy.” |
| need adjustment. |
| settings (refer to ISF Night |
|
|
|
| - Display Color on |
|
|
|
| page 43). |
|
|
|
|
|
“Out of range” appears | • | The resolution and | • | Select a compatible |
| frequency of the video |
| resolution and vertical | |
|
| card in the computer are |
| frequency (refer to |
|
| not compatible with the |
| Computer/Video Signal |
|
| PlasmaWall. |
| Compatibility on |
|
|
|
| page 64). |
|
|
|
| |
The image is too large or too | • | Image size needs | • Adjust the image size (refer | |
small. |
| adjusting. |
| to Input Position on |
|
|
|
| page 41). |
|
|
|
|
|
PlasmaWall SP Series Owner’s Operating Manual | 51 |